A comparison study of haemolysis production in three contemporary centrifugal pumps

被引:31
作者
Bottrell, S. [1 ]
Bennett, M. [1 ]
Augustin, S. [1 ]
Thuys, C. [1 ]
Schultz, B. [1 ]
Horton, A. [1 ]
Horton, S. [1 ,2 ]
机构
[1] Royal Childrens Hosp, Perfus Dept, Melbourne, Vic 3052, Australia
[2] Univ Melbourne, Dept Paediat, Melbourne, Vic, Australia
来源
PERFUSION-UK | 2014年 / 29卷 / 05期
关键词
centrifugal pump; haemolysis; ECMO; diagonal pump; VAD; hybrid pump; ECLS; FLUID-DYNAMICS ANALYSIS; LEVITRONIX; EXPERIENCE; SYSTEM; BRIDGE; DECISION;
D O I
10.1177/0267659113509000
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
One challenge in providing extracorporeal circulation is to supply optimal flow while minimising adverse effects, such as haemolysis. To determine if the recent generation constrained vortex pumps with their inherent design improvements would lead to reduced red cell trauma, we undertook a study comparing three devices. Utilizing a simulated short-term ventricular assist circuit primed with whole human blood, we examined changes in plasma free haemoglobin values over a six-day period. The three pumps investigated were the Maquet Rotaflow, the Levitronix PediVAS and the Medos Deltastream DP3.This study demonstrated that all three pumps produced low levels of haemolysis and are suitable for use in a clinical environment. The Levitronix PediVAS was significantly less haemolytic than either the Rotaflow (p<0.05) or the DP3 (p<0.05). There was no significant difference in plasma free haemoglobin between the Rotaflow and the DP3 (p=0.71).
引用
收藏
页码:411 / 416
页数:6
相关论文
共 30 条
[1]   Comparison of hydraulic and hemolytic properties of different impeller designs of an implantable rotary blood pump by computational fluid dynamics [J].
Arvand, A ;
Hahn, N ;
Hormes, M ;
Akdis, M ;
Martin, M ;
Reul, H .
ARTIFICIAL ORGANS, 2004, 28 (10) :892-898
[2]   A review of computational fluid dynamics analysis of blood pumps [J].
Behbahani, M. ;
Behr, M. ;
Hormes, M. ;
Steinseifer, U. ;
Arora, D. ;
Coronado, O. ;
Pasquali, M. .
EUROPEAN JOURNAL OF APPLIED MATHEMATICS, 2009, 20 :363-397
[3]   Pump-induced haemolysis: a comparison of short-term ventricular assist devices [J].
Bennett, M ;
Horton, S ;
Thuys, C ;
Augustin, S ;
Rosenberg, M ;
Brizard, C .
PERFUSION-UK, 2004, 19 (02) :107-111
[4]   Clinical Experience Using the Levitronix CentriMag System for Temporary Right Ventricular Mechanical Circulatory Support [J].
Bhama, Jay K. ;
Kormos, Robert L. ;
Toyoda, Yoshiya ;
Teuteberg, Jeffrey J. ;
McCurry, Kenneth R. ;
Siegenthaler, Michael P. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2009, 28 (09) :971-976
[5]  
Conrad S, 2012, ECMO EXTRACORPOREAL, P102
[6]   Clinical performance with the levitronix centrimag short-term ventricular assist device [J].
De Robertis, F ;
Birks, EJ ;
Rogers, P ;
Dreyfus, G ;
Pepper, JR ;
Khaghani, A .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2006, 25 (02) :181-186
[7]   Bridge to decision using the levitronix CentriMag short-term ventricular assist device [J].
De Robertis, Fabio ;
Rogers, Paula ;
Amrani, Mohammed ;
Petrou, Mario ;
Pepper, John R. ;
Bahrami, Toufan ;
Dreyfus, Gilles D. ;
Khaghani, Asghar ;
Birks, Emma J. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2008, 27 (05) :474-478
[8]   Development of the MEDOS/HIA DeltaStream extracorporeal rotary blood pump [J].
Göbel, C ;
Arvand, A ;
Eilers, R ;
Marseille, O ;
Bals, C ;
Meyns, B ;
Flameng, W ;
Rau, G ;
Reul, H .
ARTIFICIAL ORGANS, 2001, 25 (05) :358-365
[9]   Comparison of Two Different Minimized Extracorporeal Circulation Systems: Hematological Effects after Coronary Surgery [J].
Haneya, Assad ;
Philipp, Alois ;
Diez, Claudius ;
Ried, Michael ;
Puehler, Thomas ;
Camboni, Daniele ;
Zausig, York ;
Lehle, Karla ;
Schmid, Christof .
ASAIO JOURNAL, 2009, 55 (06) :592-597
[10]   Experience with the Jostra Rotaflow and QuadroxD oxygenator for ECMO [J].
Horton, S ;
Thuys, C ;
Bennett, M ;
Augustin, S ;
Rosenberg, M ;
Brizard, C .
PERFUSION-UK, 2004, 19 (01) :17-23