摘要
In this study a novel, simple and rapid reversed-phase high performance liquid chromatography (HPLC) procedure for simultaneous determination of vitamins A and E (retinol and alpha-tocopherol) in blood serum has been developed and validated using monolithic column and diode-array detection (DAD). The monolithic column Chromolith Performance RP-18e (100 turn x 4.6 mm) was operated at ambient temperature. One hundred percent methanol at flow rate 2.5 ml min(-1) was used as a mobile phase. Detection of both compounds was performed with diode-array detector, retinol was monitored at 325 nm and alpha-tocopherol at 295 nm. The linear dependence between peak area and concentration ranged from 0.25 to 10.00 mu mol l(-1) for retinol and 0.5-50.0 mu mol l(-1) for alpha-tocopherol. The limit of detection (LOD) for retinol was 0.02 mu mol l(-1)` and limit of quantification (LOQ) was 0.07 mu mol l(-1). The limit of detection (LOD) for alpha-tocopherol was 0.1 mu mol l(-1) and limit of quantification (LOQ) was 0.3 mu mol l(-1). Retinol was eluted in 0.8 min and alpha-tocopherol in 1.4 min. The simultaneous analysis of vitamin A and E can be achieved in less than 2 min. The implementation of monolithic column Chromolith Performance shortens the time of analysis of both vitamins four times in comparison with using traditional particulate column Pecosphere C 18 (150 mm x 4.6 mm), 5 mu m. This fact may play an important role for routine clinical analysis of biological samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 50 条
  • [21] DETERMINATION AND CONFIRMATION OF BENOMYL AND CARBENDAZIM IN WATER USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND DIODE-ARRAY DETECTION
    DHOOT, JS
    DELROSARIO, AR
    JOURNAL OF CHROMATOGRAPHY, 1993, 645 (01): : 178 - 181
  • [22] Levetiracetam determination in human serum by liquid chromatography with diode array detection
    Magali Assum, Debora
    Belen Orozco, Maria
    Ana Tantucci, Leonela
    Andres Suarez, Hector
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2017, 51 (01): : 53 - 61
  • [23] A High-Performance Liquid Chromatography with Electrochemical Detection Method Developed for the Sensitive Determination of Ascorbic Acid: Validation, Application, and Comparison with Titration, Spectrophotometric, and High-Performance Liquid Chromatography with Diode-Array Detection Methods
    Wu, Fanhua
    Xu, Fangrui
    Liu, Wen
    Chen, Sinan
    Luo, Haojie
    Cheng, Ni
    Zhao, Haoan
    Cao, Wei
    FOODS, 2023, 12 (16)
  • [24] Quantification of letermovir in human serum using high-performance liquid chromatography with diode array detection
    Isberner, Nora
    Aghai, Fatemeh
    Schirmer, Diana
    Kraus, Sabrina
    Grigoleit, Goetz Ulrich
    Klinker, Hartwig
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1159
  • [25] Simultaneous determination of vitamins C, E and β-carotene in human plasma by high-performance liquid chromatography with photodiode-array detection.
    Zhao, B
    Tham, SY
    Lu, J
    Lai, MH
    Lee, LKH
    Moochhala, SM
    JOURNAL OF PHARMACY AND PHARMACEUTICAL SCIENCES, 2004, 7 (02): : 200 - 204
  • [26] DIODE-ARRAY - NEW DIMENSIONS IN DETECTION FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    PICKERING, MV
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1990, 8 (11): : 846 - &
  • [27] Simple quantification of endogenous retinoids in bovine serum by high-performance liquid chromatography - diode-array detection
    Van Merris, V
    Meyer, E
    De Wasch, K
    Burvenich, C
    ANALYTICA CHIMICA ACTA, 2002, 468 (02) : 237 - 244
  • [28] Simultaneous Determination of Water and Fat-Soluble Vitamins in Pekmez Samples by High Performance Liquid Chromatography Coupled with Diode Array Detection
    Kucukbay, F. Zehra
    Karaca, Idil
    ASIAN JOURNAL OF CHEMISTRY, 2010, 22 (05) : 4083 - 4091
  • [29] Simultaneous determination of twelve water- and fat-soluble vitamins by high-performance liquid chromatography with diode array detection
    H. B. Li
    F. Chen
    Chromatographia, 2001, 54 : 270 - 273
  • [30] Simultaneous determination of nine water-soluble vitamins in pharmaceutical preparations by high-performance liquid chromatography with diode array detection
    Li, Hua-Bin
    Chen, Feng
    Journal of Separation Science, 2001, 24 (04) : 271 - 274