The effects of age, sex, lung size, and hyperinflation on CT lung densitometry

被引:103
作者
Gevenois, PA
Scillia, P
deMaertelaer, V
Michils, A
DeVuyst, P
Yernault, JC
机构
[1] ERASME UNIV HOSP, DEPT CHEST MED, BRUSSELS, BELGIUM
[2] FREE UNIV BRUSSELS, INST RECH INTERDISCIPLINAIRE BIOL HUMAINE & NUCL, STAT UNIT, BRUSSELS, BELGIUM
关键词
D O I
10.2214/ajr.167.5.8911175
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. To test our proposal that, on high-resolution CT scans, the relative area of the lung with attenuation values lower than -950 H (RA(950)) can be a measurement of pulmonary emphysema, we examine the possible influences of sex, age, lung size, and hyperinflation on CT lung densitometry. SUBJECTS AND METHODS. The RA(950) and the mean lung density (MLD) were measured in 42 healthy subjects (21 men, 21 women) from 23 to 71 years old, in 10 patients with asthma before and after a bronchial challenge test, and in seven patients with asthma who have irreversible hyperinflation (defined as an increased total lung capacity). RESULTS. In the healthy subjects, we found no significant difference between sexes and no significant correlation between age and the MLD, but we found a significant correlation between age and the RA(950) In addition, we found a significant correlation between the total lung capacity expressed as absolute values and both the RA(950) and the MLD. We did not observe any effect of acute airflow limitation either on the MLD or on the RA(950) in the asthmatic subjects after the bronchial challenge test. Likewise, we observed no change in either the MLD or the RA(950) in the asthmatic subjects with chronic hyperinflation. CONCLUSION. This study shows that CT lung densitometry is influenced by total lung capacity and, to a lesser degree, by age. Thus, this study suggests that normal CT attenuation values for the lung should be established.
引用
收藏
页码:1169 / 1173
页数:5
相关论文
共 24 条
[1]   NUMBER OF ALVEOLI IN HUMAN LUNG [J].
ANGUS, GE ;
THURLBECK, WM .
JOURNAL OF APPLIED PHYSIOLOGY, 1972, 32 (04) :483-+
[2]  
Brody JS, 1986, HDB PHYSL 3, P355
[3]   STANDARDIZATION OF THE MEASUREMENT OF TRANSFER-FACTOR (DIFFUSING-CAPACITY) - REPORT WORKING PARTY STANDARDIZATION OF LUNG-FUNCTION TESTS EUROPEAN-COMMUNITY FOR STEEL AND COAL - OFFICIAL STATEMENT OF THE EUROPEAN RESPIRATORY SOCIETY [J].
COTES, JE ;
CHINN, DJ ;
QUANJER, PH ;
ROCA, J ;
YERNAULT, JC .
EUROPEAN RESPIRATORY JOURNAL, 1993, 6 :41-52
[4]  
DUNNILL M. S., 1962, THORAX, V17, P329, DOI 10.1136/thx.17.4.329
[5]  
DUNNILL M. S., 1964, THORAX, V19, P443, DOI 10.1136/thx.19.5.443
[6]   Comparison of computed density and microscopic morphometry in pulmonary emphysema [J].
Gevenois, PA ;
DeVuyst, P ;
deMaertelaer, V ;
Zanen, J ;
Jacobvitz, D ;
Cosio, MG ;
Yernault, JC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (01) :187-192
[7]   Pulmonary emphysema: Quantitative CT during expiration [J].
Gevenois, PA ;
DeVuyst, P ;
Sy, M ;
Scillia, P ;
Chaminade, L ;
deMaertelaer, V ;
Zanen, J ;
Yernault, JC .
RADIOLOGY, 1996, 199 (03) :825-829
[8]   COMPARISON OF COMPUTED DENSITY AND MACROSCOPIC MORPHOMETRY IN PULMONARY-EMPHYSEMA [J].
GEVENOIS, PA ;
DEMAERTELAER, V ;
DEVUYST, P ;
ZANEN, J ;
YERNAULT, JC .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (02) :653-657
[9]  
GIBSON GJ, 1996, CLIN TESTS RESPIRATO, P151
[10]   AIRSPACE SIZE IN LUNGS OF LIFELONG NONSMOKERS - EFFECT OF AGE AND SEX [J].
GILLOOLY, M ;
LAMB, D .
THORAX, 1993, 48 (01) :39-43