Assessment of gliosis around moveable implants in the brain

被引:21
作者
Stice, Paula [1 ]
Muthuswamy, Jit [1 ]
机构
[1] Arizona State Univ, Dept Bioengn, Tempe, AZ 85287 USA
关键词
SILICON MICROELECTRODE ARRAYS; CENTRAL-NERVOUS-SYSTEM; IN-VITRO; CEREBRAL-CORTEX; IMPEDANCE CHARACTERIZATION; FOCAL ISCHEMIA; TISSUE; ELECTRODES; RESPONSES; RECORDINGS;
D O I
10.1088/1741-2560/6/4/046004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Repositioning microelectrodes post-implantation is emerging as a promising approach to achieve long-term reliability in single neuronal recordings. The main goal of this stud was to (a) assess glial reaction in response to movement of microelectrodes in the brain post-implantation and (b) determine an optimal window of time post-implantation when movement of microelectrodes within the brain would result in minimal glial reaction. Eleven Sprague-Dawley rats were implanted with two microelectrodes each that could be moved in vivo post-implantation. Three cohorts were investigated: (1) microelectrode moved at day 2 (n = 4 animals), (2) microelectrode moved at day 14 (n = 5 animals) and (3) microelectrode moved at day 28 (n = 2 animals). Histological evaluation was performed in cohorts 1-3 at four-week post-movement (30 days, 42 days and 56 days post-implantation, respectively). In addition, five control animals were implanted with microelectrodes that were not moved. Control animals were implanted for (1) 30 days (n = 1), (2) 42 days (n = 2) and (3) 56 days (n = 2) prior to histological evaluation. Quantitative assessment of glial fibrillary acidic protein (GFAP) around the tip of the microelectrodes demonstrated that GFAP levels were similar around microelectrodes moved at day 2 when compared to the 30-day controls. However, GFAP expression levels around microelectrode tips that moved at day 14 and day 28 were significantly less than those around control microelectrodes implanted for 42 and 56 days, respectively. Therefore, we conclude that moving microelectrodes after implantation is a viable strategy that does not result in any additional damage to brain tissue. Further, moving the microelectrode downwards after 14 days of implantation may actually reduce the levels of GFAP expression around the tips of the microelectrodes in the long term.
引用
收藏
页数:10
相关论文
共 51 条
[21]   THE STEREOTRODE - A NEW TECHNIQUE FOR SIMULTANEOUS ISOLATION OF SEVERAL SINGLE UNITS IN THE CENTRAL NERVOUS-SYSTEM FROM MULTIPLE UNIT RECORDS [J].
MCNAUGHTON, BL ;
OKEEFE, J ;
BARNES, CA .
JOURNAL OF NEUROSCIENCE METHODS, 1983, 8 (04) :391-397
[22]   Impedance characterization of microarray recording electrodes in vitro [J].
Merrill, DR ;
Tresco, PA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (11) :1960-1965
[23]   ADAPTATION OF THE REITBOECK METHOD OF MULTIPLE MICROELECTRODE RECORDING TO THE NEOCORTEX OF THE WAKING MONKEY [J].
MOUNTCASTLE, VB ;
REITBOECK, HJ ;
POGGIO, GF ;
STEINMETZ, MA .
JOURNAL OF NEUROSCIENCE METHODS, 1991, 36 (01) :77-84
[24]   Electrostatic microactuators for precise positioning of neural microelectrodes [J].
Muthuswamy, J ;
Okandan, M ;
Jain, T ;
Gilletti, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (10) :1748-1755
[25]   An array of microactuated microelectrodes for monitoring single-neuronal activity in rodents [J].
Muthuswamy, J ;
Okandan, M ;
Gilletti, A ;
Baker, MS ;
Jain, T .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (08) :1470-1477
[26]   Single neuronal recordings using surface micromachined polysilicon microelectrodes [J].
Muthuswamy, J ;
Okandan, M ;
Jackson, N .
JOURNAL OF NEUROSCIENCE METHODS, 2005, 142 (01) :45-54
[27]   Chronic, multisite, multielectrode recordings in macaque monkeys [J].
Nicolelis, MAL ;
Dimitrov, D ;
Carmena, JM ;
Crist, R ;
Lehew, G ;
Kralik, JD ;
Wise, SP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (19) :11041-11046
[28]   In vitro model of glial scarring around neuroelectrodes chronically implanted in the CNS [J].
Polikov, Vadim S. ;
Block, Michelle L. ;
Fellous, Jean-Marc ;
Hong, Jau-Shyong ;
Reichert, W. Monty .
BIOMATERIALS, 2006, 27 (31) :5368-5376
[29]   Response of brain tissue to chronically implanted neural electrodes [J].
Polikov, VS ;
Tresco, PA ;
Reichert, WM .
JOURNAL OF NEUROSCIENCE METHODS, 2005, 148 (01) :1-18
[30]   Rabbit and monkey visual cortex:: more than a year of recording with up to 64 microelectrodes [J].
Porada, I ;
Bondar, I ;
Spatz, WB ;
Krüger, J .
JOURNAL OF NEUROSCIENCE METHODS, 2000, 95 (01) :13-28