Simultaneous Determination of Inorganic Anions in Bottled Drinking Water by the Ion Chromatography Method

被引:7
作者
Daraei, H. [1 ]
Maleki, A. [1 ]
Mahvi, A. H. [2 ,3 ]
Alaei, L. [4 ]
Rezaee, R. [1 ]
Ghahremani, E. [1 ]
Mirzaei, N. [1 ]
机构
[1] Kurdistan Univ Med Sci, Kurdistan Environm Hlth Res Ctr, Sanandaj, Iran
[2] Univ Tehran, Sch Publ Hlth, Tehran 14174, Iran
[3] Univ Tehran, Ctr Environm Res Med Sci, Tehran 14174, Iran
[4] Univ Tehran, Inst Biochem & Biophys, Tehran 14174, Iran
关键词
ion chromatography; mineral bottled water; multicomponent analysis; inorganic anions; PERCHLORATE;
D O I
10.3103/S1063455X15050082
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Simultaneous analysis of seven inorganic anions (fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulfate-ions) was carried out in two sets of 10 brands of mineral bottled waters (Iran) using ion chromatography (IC). Waters were sampled in autumn and winter of 2010. The obtained concentrations compared with the values on the labels. It was established that concentrations of the specified ions in tested waters were within the acceptable levels of the World Health Organization (WHO) and the United States Environmental Protection Agency (USEPA). Comparison of label values with our experiments showed that 11 label values had meaningful difference from the corresponding test values. The analysis of variance (ANOVA) revealed that sampling in autumn and winter periods did not influence the content of ions in water.
引用
收藏
页码:253 / 257
页数:5
相关论文
共 19 条
[1]   Gestational exposure to high perchlorate concentrations in drinking water and neonatal thyroxine levels [J].
Amitai, Yona ;
Winston, Gary ;
Sack, Joseph ;
Wasser, Janice ;
Lewis, Matthew ;
Blount, Benjamin C. ;
Valentin-Blasini, Liza ;
Fisher, Nirah ;
Israeli, Avi ;
Leventhal, Alex .
THYROID, 2007, 17 (09) :843-850
[2]   Detection techniques in ion chromatography of inorganic ions [J].
Buchberger, WW .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (6-7) :296-303
[3]   Isotope dilution analysis of bromate in drinking water matrixes by ion chromatography with inductively coupled plasma mass spectrometric detection [J].
Creed, JT ;
Brockhoff, CA .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :722-726
[4]   ANALYSIS OF OXYHALIDE DISINFECTION BY-PRODUCTS AND OTHER ANIONS OF INTEREST IN DRINKING-WATER BY ION CHROMATOGRAPHY [J].
HAUTMAN, DP ;
BOLYARD, M .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :65-74
[5]   Determination of trace level perchlorate in drinking water and ground water by ion chromatography [J].
Jackson, PE ;
Laikhtman, M ;
Rohrer, JS .
JOURNAL OF CHROMATOGRAPHY A, 1999, 850 (1-2) :131-135
[6]   Determination of inorganic ions in drinking water by ion chromatography [J].
Jackson, PE .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (6-7) :320-329
[7]  
Lockhart E. E., 1955, J FOOD SCI, V20, P598
[8]  
Miller, 2018, STAT CHEMOMETRICS AN
[9]   Analysis of anions in drinking water by capillary ion electrophoresis [J].
Oehrle, SA .
JOURNAL OF CHROMATOGRAPHY A, 1996, 733 (1-2) :101-104
[10]  
Prabhakar A R, 2008, J Indian Soc Pedod Prev Dent, V26, P6