Comparison of liquid-liquid extraction, solid-phase extraction and co-precipitation preconcentration methods for the determination of cadmium, copper, nickel, lead and zinc in seawater

被引:187
作者
Komjarova, Irina [1 ]
Blust, Ronny [1 ]
机构
[1] Univ Antwerp, Dept Biol, B-2020 Antwerp, Belgium
关键词
analytical methods; trace metals; seawater; atomic absorption; electrothermal; spectrometry; preconcentration; optimisation;
D O I
10.1016/j.aca.2006.06.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three major types of pre-concentration methods were evaluated and optimised for the extraction and determination of Cd, Cu, Ni, Pb and Zn from seawater samples. The traditional APDC/DDDC-Freon liquid-liquid extraction method showed excellent results for a multi-elemental analysis. However, the technique is labour consuming, very sensitive to operational conditions, employs environmentally unsafe and expensive solvents and requires large sample volumes. In the solid phase extraction method, the performances of a traditional Amberlite XAD-4 and a novel Dowex Optipore V-493 were evaluated. Application of Dowex Optipore V-493 resin provided better results at low concentrations than the generally used Amberlite XAD-4 resin using low sample volumes. However, the presence of natural organic compounds may decrease extraction efficiency of both resins for Cu. Thus, a pre-treatment with UV irradiation is advantageous for samples with high organic content. Cobalt co-precipitation methods showed good Cu and Ni recoveries, but gave poor results for Cd at low concentrations. In addition, high sample volumes are required. Both solid phase and co-precipitation methods showed unsatisfactory results in determination of Pb. Finally, a summary of methods advantages are given for choosing the most suitable method. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:221 / 228
页数:8
相关论文
共 24 条
[1]   Improved dithiocarbamate/oxine solvent extraction method for the preconcentration of trace metals from seawater using metal exchange back-extraction [J].
Batterham, GJ ;
Parry, DL .
MARINE CHEMISTRY, 1996, 55 (3-4) :381-388
[2]   INTERCOMPARISON OF 5 METHODS FOR THE DETERMINATION OF TRACE-METALS IN SEA-WATER [J].
BONIFORTI, R ;
FERRAROLI, R ;
FRIGIERI, P ;
HELTAI, D ;
QUEIRAZZA, G .
ANALYTICA CHIMICA ACTA, 1984, 162 (AUG) :33-46
[3]   Solid phase extraction of trace elements [J].
Camel, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (07) :1177-1233
[4]   Use of an o-aminobenzoic acid-functionalized XAD-4 copolymer resin for the separation and preconcentration of heavy metal(II) ions [J].
Çekiç, SD ;
Filik, H ;
Apak, R .
ANALYTICA CHIMICA ACTA, 2004, 505 (01) :15-24
[5]  
DANIELSSON LG, 1982, ANAL CHIM ACTA, V114, P183
[6]   Determination of trace amounts of some metals in samples with high salt content by atomic absorption spectrometry after cobalt-diethyldithiocarbamate coprecipitation [J].
Elci, L ;
Sahin, U ;
Oztas, S .
TALANTA, 1997, 44 (06) :1017-1023
[7]   Equilibrium and kinetic properties of a fast iminodiacetate based chelating ion exchanger and its incorporation in a FIA-ICP-AES system [J].
Hashemi, P ;
Olin, A .
TALANTA, 1997, 44 (06) :1037-1053
[8]  
HENGWU C, 1997, ANAL CHIM ACTA, V353, P181
[9]   Determination of trace metals in seawater by on-line column preconcentration inductively coupled plasma mass spectrometry [J].
Hirata, S ;
Ishida, Y ;
Aihara, M ;
Honda, K ;
Shikino, O .
ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) :205-214
[10]   Studies on synthesis and application of XAD-4-salen chelate resin for separation and determination of trace elements by solid phase extraction [J].
Kim, YS ;
In, G ;
Han, CW ;
Choi, JM .
MICROCHEMICAL JOURNAL, 2005, 80 (02) :151-157