The effects of small variations in shoe heel height on gait in people with a transtibial amputation

被引:0
作者
van Oorschot, Wieneke [1 ,2 ]
Hofstad, Cheriel Josephien [1 ]
Slagman, Daan [1 ]
Van Ee, Rene Frederik [2 ]
Keijsers, Noel Leonardus Wilhelmus [1 ,3 ]
机构
[1] Sint Maartensklin, Dept Res, Nijmegen, Netherlands
[2] Sint Maartensklin, Dept Rehabil, Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Dept Rehabil, Med Ctr, Nijmegen, Netherlands
关键词
amputation; gait; prosthesis; heel height; alignment; center of pressure; symmetry; transtibial; PROSTHETIC ALIGNMENT; ENERGY-EXPENDITURE; PRESSURE; SYMMETRY; AMPUTEES; FOOT; POSTURE; SPEED;
D O I
10.1097/PXR.0000000000000097
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Shoe heel height is considered to influence prosthetic alignment, walking comfort, and gait symmetry in people with a transtibial amputation (TTA). However, research on the effect of heel height is scarce, and no evidence is available on the effects of variations smaller than 20 mm. These small heel height variations between store-bought shoes are often overlooked by people with an amputation and may cause secondary musculoskeletal problems in the long term. Objective: To examine the effects of small increases in heel height on gait symmetry in people with a TTA and healthy individuals. Study design: Experimental repeated measures study. Methods: Fourteen participants with a TTA and 15 healthy controls were included. Pressure data, spatiotemporal data, and experienced walking comfort were measured during walking with four heel height conditions: original height and increased heights of 3, 5, and 8 mm. Symmetry in center of pressure velocity (VCOP), gait parameters, and experienced walking comfort were compared between the heel heights and between healthy controls and prosthetic walkers. Results: Increased heel height resulted in a significant decrease in VCOP symmetry (P 50.001) and experienced walking comfort (P, 0.001). The VCOP trajectory of the prosthetic leg mainly differed within the first 14.5% of the stance phase. Healthy individuals showed better VCOP symmetry in all conditions (P, 0.001). Conclusions: Healthcare professionals should advice their clients to be alert of small heel height differences between store-bought shoes, especially those larger than 5 mm. A prosthetic alignment adjustment should be considered when purchasing new shoes.
引用
收藏
页码:252 / 257
页数:6
相关论文
共 31 条
[1]   PROSTHETIC ALIGNMENT EFFECTS ON GAIT SYMMETRY - A CASE-STUDY [J].
ANDRES, RO ;
STIMMEL, SK .
CLINICAL BIOMECHANICS, 1990, 5 (02) :88-96
[2]  
Blumentritt S, 1999, PROSTHET ORTHOT INT, V23, P231
[3]   Perception of socket alignment perturbations in amputees with transtibial prostheses [J].
Boone, David A. ;
Kobayashi, Toshiki ;
Chou, Teri G. ;
Arabian, Adam K. ;
Coleman, Kim L. ;
Orendurff, Michael S. ;
Zhang, Ming .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2012, 49 (06) :843-853
[4]   Gait speed and gender effects on center of pressure progression during normal walking [J].
Chiu, Min-Chi ;
Wu, Hsin-Chieh ;
Chang, Li-Yu .
GAIT & POSTURE, 2013, 37 (01) :43-48
[5]   The effect of prosthesis alignment on the symmetry of gait in subjects with unilateral transtibial amputation [J].
Chow, Daniel H. K. ;
Holmes, Andrew D. ;
Lee, Christina K. L. ;
Sin, S. W. .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2006, 30 (02) :114-128
[6]   Velocity of the center of pressure during walking [J].
Cornwall, MW ;
McPoil, TG .
JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2000, 90 (07) :334-338
[7]   The Effect of Heel Height on Gait and Posture A Review of the Literature [J].
Cowley, Emma E. ;
Chevalier, Thierry L. ;
Chockalingam, Nachiappan .
JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2009, 99 (06) :512-518
[8]   A method for analyzing joint symmetry and normalcy, with an application to analyzing gait [J].
Crenshaw, Stephanie J. ;
Richards, James G. .
GAIT & POSTURE, 2006, 24 (04) :515-521
[9]   Impact on the biomechanics of overground gait of using an 'Echelon' hydraulic ankle-foot device in unilateral trans-tibial and trans-femoral amputees [J].
De Asha, Alan R. ;
Munjal, Ramesh ;
Kulkarni, Jai ;
Buckley, John G. .
CLINICAL BIOMECHANICS, 2014, 29 (07) :728-734
[10]   Attenuation of centre-of-pressure trajectory fluctuations under the prosthetic foot when using an articulating hydraulic ankle attachment compared to fixed attachment [J].
De Asha, Alan R. ;
Johnson, Louise ;
Munjal, Ramesh ;
Kulkarni, Jai ;
Buckley, John G. .
CLINICAL BIOMECHANICS, 2013, 28 (02) :218-224