Platform switching vs regular platform implants: Nine-month post-loading results from a randomised controlled trial

被引:0
作者
Meloni, Silvio Mario [1 ]
Jovanovic, Sascha A. [2 ]
Lolli, Francesco Maria [1 ]
Pisano, Milena
De Riu, Giacomo [3 ]
De Riu, Nicola [4 ]
Luglie, Pietrina Francesca [1 ]
Tullio, Antonio [5 ]
机构
[1] Univ Hosp Sassari, Dent Unit, Sassari, Italy
[2] GIDE Inst, Los Angeles, CA USA
[3] Univ Sassari, Maxillofacial Surg Unit, I-07100 Sassari, Italy
[4] Univ Sassari, I-07100 Sassari, Italy
[5] Univ Perugia, Maxillofacial Surg Unit, I-06100 Perugia, Italy
关键词
abutment connection; dental implants; platform switching; FINITE-ELEMENT-ANALYSIS; CRESTAL BONE CHANGES; STRESS-DISTRIBUTION; SUBMERGED IMPLANTS; TITANIUM IMPLANTS; ALVEOLAR CREST; BIOLOGIC WIDTH; CLINICAL-TRIAL; DIAMETER; LENGTH;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the clinical outcome of platform switching (PS) and regular platform (RP) implants in bilateral single molar replacements. Material and methods: This study was designed as a randomised, controlled, split-mouth trial. Eighteen patients, with bilaterally missing single molars had one site randomly assigned to a PS implant or a RP implant. A total of 36 implants were bilaterally installed. Both implants were loaded with screw retained temporary crowns 3 months after implant insertion and with screw retained definitive crowns 3 months later. Outcome measures were implant/crown failure, complications, radiographic marginal bone-level changes, pocket probing depth (PPD) and bleeding on probing (BOP). Clinical data were collected at baseline 6 and 12 months after implant placement. Results: No patients dropped out and no implant failed. No prosthetic or major biological complications were observed. One year after implant placement, mean marginal bone level was 0.93 +/- 0.26 mm (95% Cl 0.81 to 1.05) in RP group and 0.84 0.23 mm (95% Cl 0.73 to 0.95) in the PS group and no statistically significant differences between the two groups were observed (P = 0.18). Mean PPD and BOP values were, 6 and 12 months after implant placement, 2.74 +/- 0.49 mm (95% Cl 2.51 to 2.97) and 1.28 +/- 0.75 (95% Cl 0.93 to 1.63) in the RP group, and 2.70 +/- 0.38 mm (95% Cl 2.53 to 2.88) and 1.39 +/- 0.78 (95% Cl 1.03 to 1.75) in the PS group respectively, with no statistical differences between groups (P = 0.81 and P = 0.16, respectively). Conclusions: No statistically significant difference was observed between platform switched and non-platform switched implants.
引用
收藏
页码:257 / 265
页数:9
相关论文
共 50 条
  • [31] Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3years results from amulticentre randomized clinicaltrial
    Rocha, Salomao
    Wagner, Wilfried
    Wiltfang, Joerg
    Nicolau, Pedro
    Moergel, Maximilian
    Messias, Ana
    Behrens, Eleonore
    Guerra, Fernando
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2016, 43 (04) : 374 - 382
  • [32] The role of dental implant abutment design on the aesthetic outcome: preliminary 3-month post-loading results from a multicentre split-mouth randomised controlled trial comparing two different abutment designs
    Esposito, Marco
    Cardaropoli, Daniele
    Gobbato, Luca
    Scutella, Fabio
    Fabianelli, Andrea
    Mascellani, Saverio
    Delli Ficorelli, Gianluca
    Mazzocco, Fabio
    Sbricoli, Luca
    Trullenque-Eriksson, Anna
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2018, 11 (01) : 77 - 87
  • [33] Crestal Bone Level Around Tissue-Level Implants Restored with Platform Matching and Bone-Level Implants Restored with Platform Switching: A 5-Year Randomized Controlled Trial
    Lago, Laura
    da Silva, Luis
    Martinez-Silva, Isabel
    Rilo, Benito
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 448 - 456
  • [34] Four-year post-loading results of full-arch rehabilitation with immediate placement and immediate loading implants: A retrospective controlled study
    Simonpieri, Alain
    Gasparro, Roberta
    Pantaleo, Giuseppe
    Mignogna, Jolanda
    Riccitiello, Francesco
    Sammartino, Gilberto
    QUINTESSENCE INTERNATIONAL, 2017, 48 (04): : 315 - 324
  • [35] Influence of abutment height and vertical mucosal thickness on early marginal bone loss around implants: A randomised clinical trial with an 18-month post-loading clinical and radiographic evaluation
    Spinato, Sergio
    Stacchi, Claudio
    Lombardi, Teresa
    Bernardello, Fabio
    Messina, Marcello
    Dovigo, Sergio
    Zaffe, Davide
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2020, 13 (03) : 279 - 290
  • [36] Do repeated changes of abutments have any influence on the stability of peri-implant tissues? One-year post-loading results from a multicentre randomised controlled trial
    Esposito, Marco
    Bressan, Eriberto
    Grusovin, Maria Gabriella
    D'Avenia, Ferdinando
    Neumann, Konrad
    Sbricoli, Luca
    Luongo, Giuseppe
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2017, 10 (01) : 57 - 72
  • [37] Impact of platform switching on inter-proximal bone levels around short implants in the posterior region; 1-year results from a randomized clinical trial
    Telleman, Gerdien
    Raghoebar, Gerry M.
    Vissink, Arjan
    Meijer, Henny J. A.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2012, 39 (07) : 688 - 697
  • [38] Influence of the loading protocol and platform switching in two-implant bar-retained overdentures: 3-year results from a randomized controlled equivalence clinical trial
    Enkling, Norbert
    Kokoschka, Franziska
    Schumacher, Daniel
    Kraus, Dominik
    Schimmel, Martin
    Abou-Ayash, Samir
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (01) : 120 - 129
  • [39] Clinical and Radiographic Evaluation of Marginal Bone Changes around Platform-Switching Implants Placed in Crestal or Subcrestal Positions: A Randomized Controlled Clinical Trial
    Kutan, Esma
    Bolukbasi, Nilufer
    Yildirim-Ondur, Esra
    Ozdemir, Tayfun
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E364 - E375
  • [40] Socket grafting with or without buccal augmentation with anorganic bovine bone at immediate post-extractive implants: 6-month after loading results from a multicenter randomised controlled clinical trial
    Zuffetti, Francesco
    Esposito, Marco
    Capelli, Matteo
    Galli, Fabio
    Testori, Tiziano
    Del Fabbro, Massimo
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2013, 6 (03) : 239 - 250