Platform switching vs regular platform implants: Nine-month post-loading results from a randomised controlled trial

被引:0
作者
Meloni, Silvio Mario [1 ]
Jovanovic, Sascha A. [2 ]
Lolli, Francesco Maria [1 ]
Pisano, Milena
De Riu, Giacomo [3 ]
De Riu, Nicola [4 ]
Luglie, Pietrina Francesca [1 ]
Tullio, Antonio [5 ]
机构
[1] Univ Hosp Sassari, Dent Unit, Sassari, Italy
[2] GIDE Inst, Los Angeles, CA USA
[3] Univ Sassari, Maxillofacial Surg Unit, I-07100 Sassari, Italy
[4] Univ Sassari, I-07100 Sassari, Italy
[5] Univ Perugia, Maxillofacial Surg Unit, I-06100 Perugia, Italy
关键词
abutment connection; dental implants; platform switching; FINITE-ELEMENT-ANALYSIS; CRESTAL BONE CHANGES; STRESS-DISTRIBUTION; SUBMERGED IMPLANTS; TITANIUM IMPLANTS; ALVEOLAR CREST; BIOLOGIC WIDTH; CLINICAL-TRIAL; DIAMETER; LENGTH;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the clinical outcome of platform switching (PS) and regular platform (RP) implants in bilateral single molar replacements. Material and methods: This study was designed as a randomised, controlled, split-mouth trial. Eighteen patients, with bilaterally missing single molars had one site randomly assigned to a PS implant or a RP implant. A total of 36 implants were bilaterally installed. Both implants were loaded with screw retained temporary crowns 3 months after implant insertion and with screw retained definitive crowns 3 months later. Outcome measures were implant/crown failure, complications, radiographic marginal bone-level changes, pocket probing depth (PPD) and bleeding on probing (BOP). Clinical data were collected at baseline 6 and 12 months after implant placement. Results: No patients dropped out and no implant failed. No prosthetic or major biological complications were observed. One year after implant placement, mean marginal bone level was 0.93 +/- 0.26 mm (95% Cl 0.81 to 1.05) in RP group and 0.84 0.23 mm (95% Cl 0.73 to 0.95) in the PS group and no statistically significant differences between the two groups were observed (P = 0.18). Mean PPD and BOP values were, 6 and 12 months after implant placement, 2.74 +/- 0.49 mm (95% Cl 2.51 to 2.97) and 1.28 +/- 0.75 (95% Cl 0.93 to 1.63) in the RP group, and 2.70 +/- 0.38 mm (95% Cl 2.53 to 2.88) and 1.39 +/- 0.78 (95% Cl 1.03 to 1.75) in the PS group respectively, with no statistical differences between groups (P = 0.81 and P = 0.16, respectively). Conclusions: No statistically significant difference was observed between platform switched and non-platform switched implants.
引用
收藏
页码:257 / 265
页数:9
相关论文
共 50 条
  • [21] Immediate occluding definitive partial fixed prosthesis versus non-occluding provisional restorations-4-month post-loading results from a pragmatic multicenter randomised controlled trial
    Heinemann, Friedhelm
    Grufferty, Brendan
    Papavasiliou, George
    Dominiak, Marzena
    Jimenez Garcia, Jaime
    Trullenque-Eriksson, Anna
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2016, 9 (01) : 47 - 56
  • [22] Inward-Inclined Implant Platform for the Amplified Platform-Switching Concept: 18-Month Follow-up Report of a Prospective Randomized Matched-Pair Controlled Trial
    Canullo, Luigi
    Rosa, Jose Carlo
    Pinto, Vicente Souza
    Francischone, Carlos Eduardo
    Goetz, Werner
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (04) : 927 - 934
  • [23] Double-blind randomized controlled trial study on post-extraction immediately restored implants using the switching platform concept: soft tissue response. Preliminary report
    Canullo, Luigi
    Iurlaro, Giorgia
    Iannello, Giuliano
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (04) : 414 - 420
  • [24] Computer-guided versus free-hand placement of immediately loaded dental implants: 1-year post-loading results of a multicentre randomised controlled trial
    Pozzi, Alessandro
    Tallarico, Marco
    Marchetti, Massimiliano
    Scarfo, Bruno
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2014, 7 (03) : 229 - 242
  • [25] Impact of implant diameter on bone level changes around platform switched implants: preliminary results of 18 months follow-up a prospective randomized match-paired controlled trial
    Canullo, Luigi
    Iannello, Giuliano
    Penarrocha, Miguel
    Garcia, Berta
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (10) : 1142 - 1146
  • [26] 1-stage versus 2-stage lateral maxillary sinus lift procedures: 4-month post-loading results of a multicenter randomised controlled trial
    Felice, Pietro
    Pistilli, Roberto
    Piattelli, Maurizio
    Soardi, Elisa
    Pellegrino, Gerardo
    Corvino, Valeria
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2013, 6 (02) : 153 - 165
  • [27] Immediate Functional Loading in the Maxilla Using Implants with Platform Switching: Five-year Results
    Romanos, George E.
    Nentwig, George-Hubertus
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (06) : 1106 - 1112
  • [28] A comparison of two dental implant systems in partially edentulous patients: 1-year post-loading results from a pragmatic multicentre randomised controlled trial
    Felice, Pietro
    Barausse, Carlo
    Blasone, Rodolfo
    Favaretto, Gianpaolo
    Stacchi, Claudio
    Ivo, Matteo Ca
    Mann, Carlo
    Buti, Jacopo
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2014, 7 (04) : 397 - 409
  • [29] The influence of repeated abutment changes on peri-implant tissue stability: 3-year post-loading results from a multicentre randomised controlled trial
    Bressan, Eriberto
    Grusovin, Maria Gabriella
    D'Avenia, Ferdinando
    Neumann, Konrad
    Sbricoli, Luca
    Luongo, Giuseppe
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2017, 10 (04) : 373 - 390
  • [30] 1-stage versus 2-stage lateral sinus lift procedures: 1-year post-loading results of a multicentre randomised controlled trial
    Felice, Pietro
    Pistilli, Roberto
    Piattelli, Maurizio
    Soardi, Elisa
    Barausse, Carlo
    Corvino, Valeria
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2014, 7 (01) : 65 - 75