Effects of different surgical techniques on mid-distal humeral shaft vascularity: open reduction and internal fixation versus minimally invasive plate osteosynthesis

被引:16
|
作者
Xue, Zichao [1 ]
Jiang, Chaolai [1 ]
Hu, Chuanzhen [2 ]
Qin, Hui [1 ]
Ding, Haoliang [1 ]
An, Zhiquan [1 ]
机构
[1] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Dept Orthopaed Surg, 600 Yishan Rd, Shanghai 200233, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Med, Dept Orthopaed Surg, Ruijin Hosp, 197 Rui Jin Er Rd, Shanghai 200025, Peoples R China
来源
BMC MUSCULOSKELETAL DISORDERS | 2016年 / 17卷
基金
中国国家自然科学基金;
关键词
Humeral fracture; Reduction; Internal fixation; Blood supply; FRACTURES; MANAGEMENT; MIPO;
D O I
10.1186/s12891-016-1224-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Humeral shaft fractures are generally managed with the conventional posterior open reduction and internal fixation (ORIF) or minimally invasive plate osteosynthesis (MIPO). This study was aimed at comparing the outcomes of these surgical techniques in terms of the vascular integrity of the mid-distal humeral shaft. Methods: Twelve upper limbs were harvested from 6 fresh cadavers. ORIF or MIPO was randomly performed on either side of each pair of limbs. The axillary artery was perfused with a latex-lead tetraoxide red solution to visualize the vascular structures. The vascular integrity of the humerus was examined by plain radiography and dissection. The periosteal filling achieved with each technique was scored and the scores compared. Results: In each limb, one main nutrient artery entering the mid-distal humeral shaft anteromedially (83.3 %) or medially (16.7 %) was first identified. No case of injury to the main nutrient artery was noted for either surgical technique. Injuries to the accessory nutrient arteries entering the mid-distal humeral shaft from the posterior aspect were absent in the MIPO cases, but occurred in 52.9 % of the ORIF cases. In addition, MIPO was also superior to the open plate technique showed superior periosteal filling than. Conclusions: Our results showed that the MIPO technique is superior to the ORIF in terms of preserving the vascular integrity of the mid-distal humeral shaft.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Effects of different surgical techniques on mid-distal humeral shaft vascularity: open reduction and internal fixation versus minimally invasive plate osteosynthesis
    Zichao Xue
    Chaolai Jiang
    Chuanzhen Hu
    Hui Qin
    Haoliang Ding
    Zhiquan An
    BMC Musculoskeletal Disorders, 17
  • [2] Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique
    An, Zhiquan
    Zeng, Bingfang
    He, Xiaojian
    Chen, Qi
    Hu, Shundong
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (01) : 131 - 135
  • [3] Minimally Invasive Plating Osteosynthesis for Mid-distal Third Humeral Shaft Fractures
    Lian, Kejian
    Wang, Lei
    Lin, Dasheng
    Chen, Zhiwen
    ORTHOPEDICS, 2013, 36 (08) : E1025 - E1032
  • [4] Comment on An et al.: Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique
    Joshi, Anil Kumar
    Singh, Saurabh
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (07) : 1069 - 1069
  • [5] Treatment of humeral shaft fractures: a new minimally-invasive plate osteosynthesis versus open reduction and internal fixation: a case control study
    Yang, Jing
    Liu, Dapeng
    Zhang, Lina
    Lu, Zhanxin
    Liu, Tang
    Tao, Cheng
    BMC SURGERY, 2021, 21 (01)
  • [6] Treatment of humeral shaft fractures: a new minimally-invasive plate osteosynthesis versus open reduction and internal fixation: a case control study
    Jing Yang
    Dapeng Liu
    Lina Zhang
    Zhanxin Lu
    Tang Liu
    Cheng Tao
    BMC Surgery, 21
  • [7] Callus Formation and Mineralization after Fracture with Different Fixation Techniques: Minimally Invasive Plate Osteosynthesis versus Open Reduction Internal Fixation
    Xu, Haitao
    Xue, Zichao
    Ding, Haoliang
    Qin, Hui
    An, Zhiquan
    PLOS ONE, 2015, 10 (10):
  • [8] Minimally Invasive Plate Osteosynthesis Posterior Approach to Distal Humeral Shaft Fractures-A Surgical Technique
    Krupko, Thomas
    Mayer, Ryan
    Scott, Alesha
    Aneja, Arun
    Moghadamian, Eric
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 : S5 - S6
  • [9] Anterior Minimally Invasive Plate Osteosynthesis for Humeral Shaft Fractures Is Safer Than Open Reduction Internal Fixation: A Matched Case-Controlled Comparison
    Randell, Matthew
    Glatt, Vaida
    Stabler, Annabelle
    Bussoletti, Timothy
    Hohmann, Erik
    Tetsworth, Kevin
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2021, 35 (08) : 424 - 429
  • [10] Reply to LTTE of Joshi, Anil and Singh, Saurabh: Comment on Zhiquan An et al. Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique
    An, Zhiquan
    Zeng, Bingfang
    He, Xiaojian
    Chen, Qi
    Hu, Shundong
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (08) : 1357 - 1357