Accuracy of Consumer Monitors for Estimating Energy Expenditure and Activity Type

被引:20
作者
Woodman, James A. [1 ,2 ]
Crouter, Scott E. [1 ]
Bassett, David R., Jr. [1 ]
Fitzhugh, Eugene C. [1 ]
Boyer, William R. [1 ]
机构
[1] Univ Tennessee, Dept Kinesiol Recreat & Sport Studies, Knoxville, TN USA
[2] Univ Vermont, Dept Med, Burlington, VT USA
关键词
ACCELEROMETRY; PUBLIC HEALTH; OXYGEN CONSUMPTION; INDIRECT CALORIMETRY; VALIDATION; ACTIVITY RECOGNITION; PHYSICAL-ACTIVITY MONITORS; ACTIVITY TRACKER; VALIDITY; ACCELEROMETER; VALIDATION; ACTIGRAPH; DEVICE; ADULTS; WORN;
D O I
10.1249/MSS.0000000000001090
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Introduction: Increasing use of consumer-based physical activity (PA) monitors necessitates that they are validated against criterion measures. Thus, the purpose of this study was to examine the accuracy of three consumer-based PA monitors for estimating energy expenditure (EE) and PA type during simulated free-living activities. Methods: Twenty-eight participants (mean +/- SD: age, 25.5 +/- 3.7 yr; body mass index, 24.9 +/- 2.6 kg.m(-2)) completed 11 activities ranging from sedentary behaviors to vigorous intensities. Simultaneous measurements were made with an Oxycon portable calorimeter (criterion), a Basis Peak and Garmin Vivofit on the nondominant wrist, and three Withings Pulse devices (right hip, shirt collar, dominant wrist). Repeated-measures ANOVA were used to examine differences between measured and predicted EE. Intraclass correlation coefficients were calculated to determine reliability of EE predictions between Withings placements. Paired samples t tests were used to determine mean differences between observed minutes and Basis Peak predictions during walking, running, and cycling. Results: On average, the Basis Peak was within 8% of measured EE for the entire PA routine (P > 0.05); however, there were large individual errors (95% prediction interval, -290.4 to +233.1 kcal). All other devices were significantly different from measured EE for the entire PA routine (P < 0.05). For activity types, Basis Peak correctly identified >= 92% of actual minutes spent walking and running (P > 0.05), and 40.4% and 0% of overground and stationary cycling minutes, respectively (P < 0.001). Conclusions: The Basis Peak was the only device that did not significantly differ from measured EE; however, it also had the largest individual errors. Additionally, the Basis Peak accurately predicted minutes spent walking and running, but not cycling.
引用
收藏
页码:371 / 377
页数:7
相关论文
共 28 条
  • [1] Monitoring Daily Function in Persons With Transfemoral Amputations Using a Commercial Activity Monitor: A Feasibility Study
    Albert, Mark V.
    Deeny, Sean
    McCarthy, Cliodhna
    Valentin, Juliana
    Jayaraman, Arun
    [J]. PM&R, 2014, 6 (12) : 1120 - 1127
  • [2] Accuracy of the vivofit activity tracker
    Alsubheen S.A.
    George A.M.
    Baker A.
    Rohr L.E.
    Basset F.A.
    [J]. Journal of Medical Engineering and Technology, 2016, 40 (06) : 298 - 306
  • [3] [Anonymous], 2008, 2008 PHYS ACT GUID A
  • [4] Comparison of Consumer and Research Monitors under Semistructured Settings
    Bai, Yang
    Welk, Gregory J.
    Nam, Yoon Ho
    Lee, Joey A.
    Lee, Jung-Min
    Kim, Youngwon
    Meier, Nathan F.
    Dixon, Philip M.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (01) : 151 - 158
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] Using pedometers to increase physical activity and improve health - A systematic review
    Bravata, Dena M.
    Smith-Spangler, Crystal
    Sundaram, Vandana
    Gienger, Allison L.
    Lin, Nancy
    Lewis, Robyn
    Stave, Christopher D.
    Olkin, Ingram
    Sirard, John R.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (19): : 2296 - 2304
  • [7] Refined Two-Regression Model for the ActiGraph Accelerometer
    Crouter, Scott E.
    Kuffel, Erin
    Haas, Jere D.
    Frongillo, Edward A.
    Bassett, David R., Jr.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (05) : 1029 - 1037
  • [8] Fitbit®: An accurate and reliable device for wireless physical activity tracking
    Diaz, Keith M.
    Krupka, David J.
    Chang, Melinda J.
    Peacock, James
    Ma, Yao
    Goldsmith, Jeff
    Schwartz, Joseph E.
    Davidson, Karina W.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 185 : 138 - 140
  • [9] The validity of consumer-level, activity monitors in healthy adults worn in free-living conditions: a cross-sectional study
    Ferguson, Ty
    Rowlands, Alex V.
    Olds, Tim
    Maher, Carol
    [J]. INTERNATIONAL JOURNAL OF BEHAVIORAL NUTRITION AND PHYSICAL ACTIVITY, 2015, 12
  • [10] Fox Susannah., 2013, Tracking for Health