Pulmonary Thermal Ablation: Comparison of Radiofrequency and Microwave Devices by Using Gross Pathologic and CT Findings in a Swine Model

被引:157
作者
Brace, Christopher L. [1 ]
Hinshaw, J. Louis [1 ]
Laeseke, Paul F. [1 ]
Sampson, Lisa A. [1 ]
Lee, Fred T., Jr. [1 ]
机构
[1] Univ Wisconsin, Dept Radiol, Ctr Clin Sci, Madison, WI 53792 USA
基金
美国国家卫生研究院;
关键词
LUNG-CANCER; COAGULATION NECROSIS; TRIAXIAL ANTENNAS; TISSUE ABLATION; PORCINE MODEL; LIVER-TUMORS; EX-VIVO; THERAPY; CONDUCTIVITY; PNEUMOTHORAX;
D O I
10.1148/radiol.2513081564
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the performance of equivalently sized radio-frequency and microwave ablation applicators in a normal porcine lung model. Materials and Methods: All experiments were approved by an institutional animal care and use committee. A total of 18 ablations were performed in vivo in normal porcine lungs. By using computed tomographic (CT) fluoroscopic guidance, a 17-gauge cooled triaxial microwave antenna (n = 9) and a 17-gauge cooled radiofrequency (RF) electrode (n = 9) were placed percutaneously. Ablations were performed for 10 minutes by using either 125 W of microwave power or 200Wof RF power delivered with an impedance-based pulsing algorithm. CT images were acquired every minute during ablation to monitor growth. Animals were sacrificed after the procedure. Ablation zones were then excised and sectioned transverse to the applicator in 5-mm increments. Minimum and maximum diameter, cross-sectional area, length, and circularity were measured from gross specimens and CT images. Comparisons of each measurement were performed by using a mixed-effects model; P < .05 was considered to indicate a significant difference. Results: Mean diameter (3.32 cm +/- 0.19 [standard deviation] vs 2.70 cm +/- 0.23, P < .001) was 25% larger with microwave ablation and mean cross-sectional area (8.25 cm(2) +/- 0.92 vs 5.45 cm(2) +/- 1.14, P < .001) was 50% larger with microwave ablation, compared with RF ablation. With microwave ablation, the zones of ablation were also significantly more circular in cross section (mean circularity, 0.90 +/- 0.06 vs 0.82 +/- 0.09; P < .05). One small pneumothorax was noted during RF ablation but stabilized without intervention. Conclusion: Microwave ablation with a 17-gauge high-power triaxial antenna creates larger and more circular zones of ablation than does a similarly sized RF applicator in a preclinical animal model. Microwave ablation may be a more effective treatment of lung tumors. (C) RSNA, 2009
引用
收藏
页码:705 / 711
页数:7
相关论文
共 34 条
[1]  
[Anonymous], GUID CAR US LAB AN
[2]   Microwave ablation with multiple simultaneously powered small-gauge triaxial antennas: Results from an in vivo swine liver model [J].
Brace, Christopher L. ;
Laeseke, Paul F. ;
Sampson, Lisa A. ;
Frey, Tina M. ;
van der Weide, Daniel W. ;
Lee, Fred T., Jr. .
RADIOLOGY, 2007, 244 (01) :151-156
[3]   Microwave ablation with a single small-gauge triaxial antenna: In vivo porcine liver model [J].
Brace, Christopher L. ;
Laeseke, Paul F. ;
Sampson, Lisa A. ;
Frey, Tina M. ;
van der Weide, Daniel W. ;
Lee, Fred T., Jr. .
RADIOLOGY, 2007, 242 (02) :435-440
[4]   Microwave ablation with a triaxial antenna:: Results in ex vivo bovine liver [J].
Brace, CL ;
Laeseke, PF ;
van der Weide, DW ;
Lee, FT .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2005, 53 (01) :215-220
[5]  
DIAZ T, 2008, WORLD C INT ONC LOS
[6]   Microwave ablation with triaxial antennas tuned for lung: Results in an in vivo porcine model [J].
Durick, Nathan A. ;
Laeseke, Paul F. ;
Broderick, Lynn S. ;
Lee, Fred T., Jr. ;
Sampson, Lisa A. ;
Frey, Tina M. ;
Warner, Thomas F. ;
Fine, Jason P. ;
Van der Weide, Daniel W. ;
Brace, Christopher L. .
RADIOLOGY, 2008, 247 (01) :80-87
[7]  
Feng Weijian, 2002, Zhonghua Zhongliu Zazhi, V24, P388
[8]   Microwave coagulation therapy in canine peripheral lung tissue [J].
Furukawa, K ;
Miura, T ;
Kato, Y ;
Okada, S ;
Tsutsui, H ;
Shimatani, H ;
Kajiwara, N ;
Taira, M ;
Saito, M ;
Kato, H .
JOURNAL OF SURGICAL RESEARCH, 2005, 123 (02) :245-250
[9]   The dielectric properties of biological tissues .2. Measurements in the frequency range 10 Hz to 20 GHz [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2251-2269
[10]   Saline infusion markedly reduces impedance and improves efficacy of pulmonary radiofrequency ablation [J].
Gananadha, S ;
Morris, DL .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2004, 27 (04) :361-365