Comparison of chest compression quality between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method during CPR

被引:10
作者
Park, Sang-Sub [1 ,2 ]
机构
[1] ChungCheong Univ, Dept Emergency Med Technol, Cheongju, South Korea
[2] Korea Univ, Grad Sch Pharm, Jochiwon Eup 339700, Sejong Si, South Korea
关键词
Cardiopulmonary resuscitation; smartphone; application; chest compression; CARDIOPULMONARY-RESUSCITATION; DECOMPRESSION;
D O I
10.3233/THC-140791
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The purpose of this study is to grasp difference in quality of chest compression accuracy between the modified chest compression method with the use of smartphone application and the standardized traditional chest compression method. Participants were progressed 64 people except 6 absentees among 70 people who agreed to participation with completing the CPR curriculum. In the classification of group in participants, the modified chest compression method was called as smartphone group (33 people). The standardized chest compression method was called as traditional group (31 people). The common equipments in both groups were used Manikin for practice and Manikin for evaluation. In the meantime, the smartphone group for application was utilized Android and iOS Operating System (OS) of 2 smartphone products (G, i). The measurement period was conducted from September 25th to 26th, 2012. Data analysis was used SPSS WIN 12.0 program. As a result of research, the proper compression depth (mm) was shown the proper compression depth (p < 0.01) in traditional group (53.77 mm) compared to smartphone group (48.35 mm). Even the proper chest compression (%) was formed suitably (p < 0.05) in traditional group (73.96%) more than smartphone group (60.51%). As for the awareness of chest compression accuracy, the traditional group (3.83 points) had the higher awareness of chest compression accuracy (p < 0.001) than the smartphone group (2.32 points). In the questionnaire that was additionally carried out 1 question only in smartphone group, the modified chest compression method with the use of smartphone had the high negative reason in rescuer for occurrence of hand back pain (48.5%) and unstable posture (21.2%).
引用
收藏
页码:351 / 358
页数:8
相关论文
共 17 条
  • [1] American Heart Association(AHA), 2010, 2010 AM HEART ASS 5
  • [2] Incomplete chest wall decompression: a clinical evaluation of CPR performance by EMS personnel and assessment of alternative manual chest compression-decompression techniques
    Aufderheide, TP
    Pirrallo, RG
    Yannopoulos, D
    Klein, JP
    von Briesen, C
    Sparks, CW
    Deja, KA
    Conrad, CJ
    Kitscha, DJ
    Provo, TA
    Lurie, KG
    [J]. RESUSCITATION, 2005, 64 (03) : 353 - 362
  • [3] Choi JA, 2012, PUBLIC HLTH WEEKLY R, V5, P777
  • [4] Improved survival after out-of-hospital cardiac arrest is associated with an increase in proportion of emergency crew-witnessed cases and bystander cardiopulmonary resuscitation
    Hollenberg, Jacob
    Herlitz, Johan
    Lindqvist, Jonny
    Riva, Gabriel
    Bohm, Katarina
    Rosenqvist, Marten
    Svensson, Leif
    [J]. CIRCULATION, 2008, 118 (04) : 389 - 396
  • [5] KACPR, 2011, 2011 KOR GUID CPR EC
  • [6] Koo MJ, 2012, J KOREAN SOC COMPUTE, V20, P87
  • [7] Kovic I, 2010, CPR PRO APP
  • [8] Mobile phone in the Chain of Survival
    Kovic, Ivor
    Lulic, Ileana
    [J]. RESUSCITATION, 2011, 82 (06) : 776 - 779
  • [9] Frequency of rib and sternum fractures associated with out-of-hospital cardiopulmonary resuscitation is underestimated by conventional chest X-ray
    Lederer, W
    Mair, D
    Rabl, W
    Baubin, M
    [J]. RESUSCITATION, 2004, 60 (02) : 157 - 162
  • [10] Cardiopulmonary resuscitation-associated major liver injury
    Meron, Giora
    Kurkciyan, Istepan
    Sterz, Fritz
    Susani, Martin
    Domanovits, Hans
    Tobler, Karin
    Bohdjalian, Arthur
    Laggner, Anton N.
    [J]. RESUSCITATION, 2007, 75 (03) : 445 - 453