Using scattering and absorption spectra as MCR-hard model constraints for diffuse reflectance measurements of tablets

被引:39
作者
Kessler, Waltraud [1 ]
Oelkrug, Dieter [2 ]
Kessler, Rudolf [3 ]
机构
[1] Steinbeis Transfer Ctr Proc Control & Data Anal, D-72762 Reutlingen, Germany
[2] Univ Tubingen, Inst Phys & Theoret Chem, D-72076 Tubingen, Germany
[3] Reutlingen Univ, Reutlingen Res Inst, D-72762 Reutlingen, Germany
关键词
Scatter correction; Scattering coefficient; Multivariate curve resolution; Multivariate curve resolution-alternating least square; Diffuse reflectance; MULTIVARIATE CURVE RESOLUTION; MULTIPLICATIVE SIGNAL CORRECTION; POWDER; SIZE;
D O I
10.1016/j.aca.2009.01.057
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
One of the most often used tools in process analytical technology (PAT) is NIR spectroscopy as a non-destructive fast and reliable method to identify and quantify active pharmaceutical ingredients (API) in tablets. Very little work has been devoted to analyse the effects of scatter on quantitative analysis of the chemical composition. A novel approach to compensate scatter in reflectance spectroscopy which is more science based will be presented here. The basic assumption is to determine in step 1 a separate scattering spectral fingerprint, denoted as S spectra, and an absorption spectral fingerprint, denoted as K spectra. In the second step, the two spectra may then be used as input to the alternating least square (ALS) algorithm in multivariate curve resolution (MCR) in order to account for the spectral distortions due to the interaction of scatter and absorption. Standard tablets with a mass of 1.5 g and a diameter of 20 mm (thickness approx. 3.4mm, optically infinite) were prepared according to a central composite design by mixing theophyllin, magnesiumstearate and cellactose at three different compactions of 31, 156 and 281 MPa. The samples are measured by an UV/Vis/NIR spectrometer attached with an integrating sphere in the wavelength range from 500 up to 2100nm. The diffuse reflectance spectra of the center point sample with an optically infinite thickness R-infinity as well as a sample of finite thickness R-0 ("optically thin") is measured as reference for the S and K spectra which are then calculated with the exponential solution of the Kubelka-Munk equation. After normalization, the S spectrum and the K spectrum of a single tablet are integrated as hard model constraints into the MCR-ALS procedure. In comparison to PLS modeling with EMSC pretreatment of the spectra, the hard model constrained MCR-ALS algorithm results in an improved prediction of the concentration of the API together with a higher robustness of the calibration models. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 134
页数:8
相关论文
共 29 条
[1]  
[Anonymous], 2006, PROZESSANALYTIK STRA
[2]  
[Anonymous], 2002, PHARM MED APPL NEARI, DOI DOI 10.1201/9780203910153
[3]   Self-modeling curve resolution (SMCR) analysis of near-infrared (NIR) imaging data of pharmaceutical tablets [J].
Awa, Kimie ;
Okumura, Takehiro ;
Shinzawa, Hideyuki ;
Otsuka, Makoto ;
Ozaki, Yukihiro .
ANALYTICA CHIMICA ACTA, 2008, 619 (01) :81-86
[4]  
Bakeev KA, 2005, PROCESS ANALYTICAL TECHNOLOGY: SPECTROSCOPIC TOOLS AND IMPLEMENTATION STRATEGIES FOR THE CHEMICAL AND PHARMACEUTICAL INDUSTRIES, P424, DOI 10.1002/9780470988459.ch12
[5]   Effective sample size in diffuse reflectance near-IR spectrometry [J].
Berntsson, O ;
Burger, T ;
Folestad, S ;
Danielsson, LG ;
Kuhn, J ;
Fricke, J .
ANALYTICAL CHEMISTRY, 1999, 71 (03) :617-623
[6]   Multivariate curve resolution of rapid-scan FTIR difference spectra of quinone photoreduction in bacterial photosynthetic membranes [J].
Blanchet, L. ;
Mezzetti, A. ;
Ruckebusch, C. ;
Huvenne, J. -P. ;
de Juan, A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (05) :1863-1873
[7]   Quantitative determination of the scattering and absorption coefficients from diffuse reflectance and transmittance measurements: Application to pharmaceutical powders [J].
Burger, T ;
Kuhn, J ;
Caps, R ;
Fricke, J .
APPLIED SPECTROSCOPY, 1997, 51 (03) :309-317
[8]  
Dahm D.J., 2007, INTERPRETING DIFFUSE
[9]   Chemometrics applied to unravel multicomponent processes and mixtures - Revisiting latest trends in multivariate resolution [J].
de Juan, A ;
Tauler, R .
ANALYTICA CHIMICA ACTA, 2003, 500 (1-2) :195-210
[10]   Multivariate curve resolution-alternating least squares (MCR-ALS) applied to spectroscopic data from monitoring chemical reactions processes [J].
Garrido, M. ;
Rius, F. X. ;
Larrechi, M. S. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 390 (08) :2059-2066