Development of Innovative Aerogel Based Plasters: Preliminary Thermal and Acoustic Performance Evaluation

被引:91
作者
Buratti, Cinzia [1 ]
Moretti, Elisa [1 ]
Belloni, Elisa [1 ]
Agosti, Fabrizio [2 ]
机构
[1] Univ Perugia, Dept Ind Engn, I-06125 Perugia, PG, Italy
[2] Agosti Nanotherm Srl, I-39055 Laives, BZ, Italy
关键词
aerogel based plasters; silica aerogel; thermal and acoustic performance; refurbishment of buildings; OF-THE-ART;
D O I
10.3390/su6095839
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The thermal and acoustic properties of innovative insulating systems used as building coatings were investigated: Granular silica aerogel was mixed with natural plaster in different percentages. This coating solution is transpiring and insulating, thanks to the use of a natural lime coat and aerogel, a highly porous light material with very low thermal conductivity. The thermal conductivity of the proposed solution was evaluated by means of a Heat Flow meter apparatus (EN ISO 12667), considering different percentages of aerogel. The natural plaster without aerogel has a thermal conductivity of about 0.50 W/m K; considering a percentage of granular aerogel of about 90% in volume, the thermal conductivity of the insulating natural coating falls to 0.050 W/m K. Increasing the percentage of granular aerogel, a value of about 0.018-0.020 W/m K can be reached. The acoustic properties were also evaluated in terms of the acoustic absorption coefficient, measured by means of a Kundt's Tube (ISO 10534-2). Two samples composed by a plasterboard support, an insulation plaster with aerogel (thicknesses 10 mm and 30 mm respectively) and a final coat were assembled. The results showed that the absorption coefficient strongly depends on the final coat, so the aerogel-based plaster layer moderately influences the final value. The application of this innovative solution can be a useful tool for new buildings, but also for the refurbishment of existing ones. This material is in development: until now, the best value of the thermal conductivity obtained from manufacturers is about 0.015 W/m K.
引用
收藏
页码:5839 / 5852
页数:14
相关论文
共 22 条
  • [1] [Anonymous], C51810 ASTM
  • [2] [Anonymous], 1991, ISO 8301 Thermal Insulation-Determination of Steady-State Thermal Resistance and Related Properties-Heat Flow Meter Apparatus
  • [3] [Anonymous], ENERGY BUILD
  • [4] [Anonymous], 12667 EN ISO
  • [5] [Anonymous], 1994, 10351 UNI
  • [6] Buratti C, 2013, WOODHEAD PUBL MATER, P207, DOI 10.1533/9780857098832.2.207
  • [7] Evolutive Housing System: Refurbishment with new technologies and unsteady simulations of energy performance
    Buratti, C.
    Belloni, E.
    Palladino, D.
    [J]. ENERGY AND BUILDINGS, 2014, 74 : 173 - 181
  • [8] Unsteady simulation of energy performance and thermal comfort in non-residential buildings
    Buratti, C.
    Moretti, E.
    Belloni, E.
    Cotana, F.
    [J]. BUILDING AND ENVIRONMENT, 2013, 59 : 482 - 491
  • [9] Experimental performance evaluation of aerogel glazing systems
    Buratti, C.
    Moretti, E.
    [J]. APPLIED ENERGY, 2012, 97 : 430 - 437
  • [10] Glazing systems with silica aerogel for energy savings in buildings
    Buratti, C.
    Moretti, E.
    [J]. APPLIED ENERGY, 2012, 98 : 396 - 403