Dual-energy x-ray absorptiometry in small subjects: Influence of dual-energy x-ray equipment on assessment of mineralization and body composition in newborn piglets

被引:13
|
作者
Picaud, JC
Nyamugabo, K
Braillon, P
Lapillonne, A
Claris, O
Delmas, P
Meunier, P
Salle, B
Rigo, J
机构
[1] Hop Edouard Herriot, INSERM U403, Serv Neonatal, F-69437 Lyon 03, France
[2] Hop Edouard Herriot, Neonatal Unit, Dept Radiol, F-69437 Lyon, France
[3] Hop Edouard Herriot, Human Nutr Res Ctr, Dept Radiol, F-69437 Lyon 03, France
[4] Univ Liege, Citadelle Hosp, Neonatal Unit, B-4000 Liege, Belgium
关键词
D O I
10.1203/00006450-199912000-00011
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
There is a growing body of literature that describes the use of dual-energy x-ray absorptiometry (DXA) for bone mineral content (BMC) and fat mass (FM) assessment in neonates, but the reproducibility and accuracy of the method are still controversial. Two different software programs have been developed for use on Hologic densitometers: the Pediatric Whole Body (PWB) and the Infant Whole Body (IWB) programs. They differ in scan time, radiation exposure, and in the algorithm used to assess BMC. We evaluated the reproducibility and accuracy of PWB and IWB in newborn piglets. Reproducibility of body mass (BM), FM, and BMC measurements from PWB and IWB were similar. BM agreed well with scale weight with both software programs; IWB was within +/- 0.58 and PWB was within +/- 0.3% of scale weight. FM was highly correlated with carcass fat (PWB: r = 0.962; IWB: r = 0.980). Errors in the DXA estimation of fat were similar with PWB and IWB. With both software programs, BMC was highly correlated with carcass calcium (PWB: r 0.925, IWB: r = 0.987), but errors in the DXA estimation of calcium were about twice as high with PWB (+/-16.9%) than with IWB (+/-9.2%). In four piglets, the addition of a layer of porcine lard was associated with an increase in BMC; this effect was more pronounced with PWB (+156%) than with IWB (+15%). The IWB software provided BMC measurements that were more precise, accurate, and stable in the presence of added fat than the measurements obtained with PWB, indicating that IWB is superior to PWB for in vivo determination of BMC and body composition.
引用
收藏
页码:772 / 777
页数:6
相关论文
共 50 条
  • [1] Dual-Energy X-Ray Absorptiometry in Small Subjects: Influence of Dual-Energy X-Ray Equipment on Assessment of Mineralization and Body Composition in Newborn Piglets
    Jean-Charles Picaud
    Kindja Nyamugabo
    Pierre Braillon
    Alexandre Lapillonne
    Olivier Claris
    Pierre Delmas
    Pierre Meunier
    Bernard Salle
    Jacques Rigo
    Pediatric Research, 1999, 46 : 772 - 772
  • [2] Dual-energy X-ray absorptiometry and body composition
    Laskey, MA
    NUTRITION, 1996, 12 (01) : 45 - 51
  • [3] Dual-energy X-ray absorptiometry and body composition
    Plank, LD
    CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2005, 8 (03): : 305 - 309
  • [4] DUAL-ENERGY X-RAY ABSORPTIOMETRY IN THE NEWBORN
    SALLE, BL
    LAPILLONNE, A
    BRAILLON, P
    ARCHIVES FRANCAISES DE PEDIATRIE, 1993, 50 (07): : 545 - 546
  • [5] Body composition assessment by dual-energy X-ray absorptiometry (DXA)
    Andreoli, A.
    Scalzo, G.
    Masala, S.
    Tarantino, U.
    Guglielmi, G.
    RADIOLOGIA MEDICA, 2009, 114 (02): : 286 - 300
  • [6] Dual-energy X-ray absorptiometry
    Braillon, Pierre
    Peretti, Noel
    NUTRITION CLINIQUE ET METABOLISME, 2011, 25 (02): : 91 - 96
  • [7] Dual-energy X-ray Absorptiometry
    Jain, Rajesh K.
    Vokes, Tamara
    JOURNAL OF CLINICAL DENSITOMETRY, 2017, 20 (03) : 291 - 303
  • [8] Body composition analysis of small pigs by dual-energy X-ray absorptiometry
    Mitchell, AD
    Scholz, AM
    Conway, JM
    JOURNAL OF ANIMAL SCIENCE, 1998, 76 (09) : 2392 - 2398
  • [9] ASSESSMENT OF WHOLE-BODY COMPOSITION WITH DUAL-ENERGY X-RAY ABSORPTIOMETRY
    SLOSMAN, DO
    CASEZ, JP
    PICHARD, C
    ROCHAT, T
    FERY, F
    RIZZOLI, R
    BONJOUR, JP
    MORABIA, A
    DONATH, A
    RADIOLOGY, 1992, 185 (02) : 593 - 598
  • [10] Body composition by dual-energy x-ray absorptiometry in women with fibromyalgia
    Marques Teles Lobo, Marcia Maria
    Paiva, Eduardo dos Santos
    Andretta, Aline
    Madalozzo Schieferdecker, Maria Eliana
    REVISTA BRASILEIRA DE REUMATOLOGIA, 2014, 54 (04) : 273 - 278