Numerical simulations for swirlmeter on flow fields and metrological performance

被引:14
作者
Chen, Desheng [1 ]
Cui, Baoling [1 ]
Zhu, Zuchao [1 ]
机构
[1] Zhejiang Sci Tech Univ, Key Lab Fluid Transmiss Technol Zhejiang Prov, Second Ave 928, Hangzhou 310018, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Meter factor; numerical simulation; pressure fluctuation; swirlmeter; vortex precession; PRESSURE; METER; FLOWMETER;
D O I
10.1177/0142331216673424
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Measurements of flow rates of fluids are important in industrial applications. Swirlmeters (vortex precession meters) are widely used in the natural gas industry because of their advantage in having a large measurement range and strong output signal. In this study, using air as a working medium, computational fluid dynamics (CFD) simulations of a swirlmeter were conducted using the Reynolds-averaged Navier-Stokes (RANS) and renormalization group (RNG) k-epsilon turbulence models. The internal flow characteristics and the influence of the tube structure (geometric parameter of flow passage) on metrological performance were studied, with a particular focus on the meter factor. Calibration experiments were performed to validate the CFD predictions; the results show good agreement with those from simulations. From the streamline distributions, a clear vortex precession is found in the throat region. At the end of throat, the pressure fluctuation reached a maximum accompanied by the largest shift in the vortex core from the centreline. There exists a large reverse flow zone in the vortex core region in the convergent section. To mitigate the influence of reverse flow on vortex precession, a suitable length of throat is required. For a larger convergent angle, the fluid undergoes higher acceleration leading to an increase in velocity that produces more intensive pressure fluctuations. The minor diameter of the throat also produces a higher velocity and larger meter factor. Compared with both divergent angle and throat length, the convergent angle and throat diameter play a more important role in determining precession frequency.
引用
收藏
页码:1072 / 1081
页数:10
相关论文
共 18 条
[1]   A dual phase-locked loop for vortex flow metering [J].
Clarke, DW ;
Ghaoud, T .
FLOW MEASUREMENT AND INSTRUMENTATION, 2003, 14 (1-2) :1-11
[2]  
DIJSTELBHH, 1970, J PHYS E, V3, P886
[3]  
Fu Xin, 2001, Chinese Journal of Mechanical Engineering, V14, P9
[4]   Analysis of high pressure tests on wet gas flow metering with a Venturi meter [J].
Gajan, P. ;
Decaudin, Q. ;
Couput, J. P. .
FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 44 :126-131
[5]   Modelling and tracking a vortex flow-meter signal [J].
Ghaoud, T ;
Clarke, DW .
FLOW MEASUREMENT AND INSTRUMENTATION, 2002, 13 (03) :103-117
[6]   Nonadiabatic Condition on the Natural Gas Energy Custody Transfer Using Orifice Flow Meter [J].
Gunawan ;
Tjokronegoro, H. A. ;
Leksono, E. ;
Nugraha, N. .
MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2015, 30 (02) :77-84
[7]   Comparison of pressure and ultrasound measurements in vortex flow meters [J].
Hans, V ;
Windorfer, H .
MEASUREMENT, 2003, 33 (02) :121-133
[8]   FLOW MEASUREMENT BY A NEW PUSH-PULL SWIRLMETER [J].
HEINRICHS, K .
SENSORS AND ACTUATORS A-PHYSICAL, 1991, 27 (1-3) :809-813
[9]   Study on discharge coefficient of perforated orifices as a new kind of flowmeter [J].
Huang, Shanfang ;
Ma, Taiyi ;
Wang, Dong ;
Lin, Zonghu .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 46 :74-83
[10]  
Lee DT, 1979, T CHINESE SOC AGR MA, V10, P36