Feasibility of a resorbable anterior cervical graft containment plate

被引:14
作者
Ames, CP [1 ]
Cornwall, GB
Crawford, NR
Nottmeier, E
Chamberlain, RH
Sonntag, VKH
机构
[1] Univ Calif San Francisco, Dept Neurol Surg, San Francisco, CA 94143 USA
[2] Barrow Neurol Inst, Dept Neurosurg, Spinal Biomech Res Lab, Phoenix, AZ 85013 USA
[3] MacroPore Biosurg Inc, San Diego, CA USA
关键词
bioabsorbable implant; discectomy; cervical spine;
D O I
10.3171/spi.2002.97.4.0440
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
In this article the authors review the history of anterior cervical plating for one- and two-level discectomy for degenerative disease and provide background justification for the design and testing of a cervical plate composed of a resorbable material. The design of the plate is discussed with special reference to modifications of its design and tools compared with metallic plates that are necessary because of the different mechanical properties of the less rigid material. The cadaveric and animal in vivo testing methodologies are described, and a novel testing method for reliably quantifying graft containment is also described. Data from a representative sample are presented. Advantages and disadvantages of resorbable plating are discussed.
引用
收藏
页码:440 / 446
页数:7
相关论文
共 12 条
[1]  
AMES CD, UNPUB BIOMECHANICAL
[2]  
Branch C L Jr, 1999, Clin Neurosurg, V45, P22
[3]   Dynamic cervical plates - Biomechanical evaluation of load sharing and stiffness [J].
Brodke, DS ;
Gollogly, S ;
Mohr, RA ;
Nguyen, BK ;
Dailey, AT ;
Bachus, KN .
SPINE, 2001, 26 (12) :1324-1329
[4]   Outcome analysis of noninstrumented anterior cervical discectomy and interbody fusion in 348 patients [J].
Cauthen, JC ;
Kinard, RE ;
Vogler, JB ;
Jackson, DE ;
DePaz, OB ;
Hunter, OL ;
Wasserburger, LB ;
Williams, VM .
SPINE, 1998, 23 (02) :188-192
[5]   Internal Le Fort III distraction with biodegradable devices [J].
Cohen, SR ;
Holmes, RE .
JOURNAL OF CRANIOFACIAL SURGERY, 2001, 12 (03) :264-272
[6]   AN APPARATUS FOR APPLYING PURE NONCONSTRAINING MOMENTS TO SPINE SEGMENTS IN-VITRO [J].
CRAWFORD, NR ;
BRANTLEY, AGU ;
DICKMAN, CA ;
KOENEMAN, EJ .
SPINE, 1995, 20 (19) :2097-2100
[7]   Biomechanical evaluation of anterior cervical spine stabilization [J].
Grubb, MR ;
Currier, BL ;
Shih, JS ;
Bonin, V ;
Grabowski, JJ ;
Chao, EYS .
SPINE, 1998, 23 (08) :886-892
[8]   Anterior cervical plating enhances arthrodesis after discectomy and fusion with cortical allograft [J].
Kaiser, MG ;
Haid, RW ;
Subach, BR ;
Barnes, B ;
Rodts, GE .
NEUROSURGERY, 2002, 50 (02) :229-236
[9]   Cranial base reconstruction after transsphenoidal surgery with bioabsorbable implants: Technical note [J].
Kaptain, GJ ;
Vincent, DA ;
Laws, ER .
NEUROSURGERY, 2001, 48 (01) :232-233
[10]   Anterior cervical discectomy with freeze-dried fibula allograft - Overview of 317 cases and literature review [J].
Martin, GJ ;
Haid, RW ;
MacMillan, M ;
Rodts, GE ;
Berkman, R .
SPINE, 1999, 24 (09) :852-858