Hydrocarbons as Alternate Refrigerants to Replace R134a in Domestic Refrigerators

被引:7
作者
Siddegowda, Parashurama [1 ]
Sannappagowda, Govindegowda Mundur [2 ]
Jain, Vaibhav [3 ]
Gowda, Satheesh Javare [4 ]
机构
[1] JSSATE, Mech Engn Dept, Bengaluru 560060, India
[2] Vivekananda Coll Engn & Technol, Puttur 574203, DK, India
[3] MAIT, Mech & Automat Engn Dept, New Delhi 110086, India
[4] SJBIT, Dept Mech Engn, Bengaluru 560060, India
来源
REVUE DES COMPOSITES ET DES MATERIAUX AVANCES-JOURNAL OF COMPOSITE AND ADVANCED MATERIALS | 2019年 / 29卷 / 02期
关键词
COP; compressor work input; discharge temperature; displacement volume; volumetric efficiency; MIXTURES; PROPANE; HFC134A;
D O I
10.18280/rcma.290204
中图分类号
TB33 [复合材料];
学科分类号
摘要
The thermodynamic properties of hydrocarbons namely Propane, Cyclopropane, Propene, Methyl acetylene, Propadiene and Dimethyether as alternatives to replace R134a have been predicted using SRK EOS. The values of vapour pressure, liquid specific volume, vapour specific volume, liquid enthalpy, vapour enthalpy, liquid entropy, vapour entropy have been estimated over the temperature range from -250 degrees C to +550 degrees C. Simulation of 89W domestic refrigerator is carried out using ten state point vapour compression cycle. The theoretical performances of the hydrocarbons have been comparatively assessed using standard refrigeration parameters. According to our results, Propane, Propene are appropriate and recommended as alternatives of R134a with lower displacement compressor and Cyclopropane as direct substitute. Also implications with respect to material and lubricant oil compatibility, heat transfer characteristics are discussed.
引用
收藏
页码:95 / 99
页数:5
相关论文
共 27 条
  • [1] [Anonymous], 1989, ASHRAE Handbook: Fundamentals
  • [2] CFCS IN TRANSITION
    ATWOOD, T
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1988, 11 (04): : 234 - 238
  • [3] Babu A. T. P., 1997, THESIS
  • [4] PERFORMANCE EVALUATION OF ENVIRONMENTALLY BENIGN REFRIGERANTS IN HEAT-PUMPS 2 - AN EXPERIMENTAL-STUDY WITH HFC134A
    BANSAL, PK
    DUTTO, T
    HIVET, B
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1992, 15 (06): : 349 - 356
  • [5] Bougard J., 1990, P INT C BRUSS 19 20, P66
  • [6] Calm J.M., 2001, ENG SYSTEMS, V18, P74
  • [7] RETROFITTING HFC134A INTO EXISTING CFC12 SYSTEMS
    CARPENTER, NE
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1992, 15 (06): : 332 - 339
  • [8] COMPARATIVE-ASSESSMENT OF HFC134A AND SOME REFRIGERANTS AS ALTERNATIVES TO CFC12
    DEVOTTA, S
    GOPICHAND, S
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1992, 15 (02): : 112 - 118
  • [9] Hydrocarbons as refrigerants - an overview
    Granryd, E
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (01): : 15 - 24
  • [10] THE USE OF PROPANE IN DOMESTIC REFRIGERATORS
    JAMES, RW
    MISSENDEN, JF
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1992, 15 (02): : 95 - 100