Improvement of surface acoustic wave gas and biosensor response characteristics using a capacitive coupling technique

被引:30
|
作者
Bender, F [1 ]
Länge, K [1 ]
Voigt, A [1 ]
Rapp, M [1 ]
机构
[1] Forschungszentrum Karlsruhe, Inst Instrumental Anal, D-76021 Karlsruhe, Germany
关键词
D O I
10.1021/ac035019+
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As for many other electronic devices and circuits, electrical contact to surface acoustic wave sensors is usually made using bonding wires. Ibis technique is known to result in reliable contact under most conditions, but it does so with several disadvantages. First, electrical contact is not reversible, impeding replacement of sensor devices. Second, bonding wires are quite delicate and should not be exposed to high gas or liquid flows. Third, the presence of bonding wires may limit the potential to miniaturize a sensor housing or flow cell. Therefore, a capacitive coupling technique was developed to replace bonding wires. This permitted redesign of flow cells and sensor arrays, resulting in flow cell volumes of 80 muL to 60 nL. As a consequence, response times were reduced to 1-2 s in gas sensing and a few minutes in liquid sensing, respectively. At the same time, sensor devices can be easily replaced, and the system is less susceptible to malfunction.
引用
收藏
页码:3837 / 3840
页数:4
相关论文
共 50 条
  • [1] Development of Biosensor Using Surface Acoustic Wave
    Kim, Gi-Beum
    Chong, Woo-Suk
    Kim, Seong-Hyun
    Kim, Kyong
    Jeong, Seong-Hwan
    Kwon, Tae-Kyu
    Kim, Nam-Gyun
    Hong, Chul-Un
    IECON 2004: 30TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOL 2, 2004, : 1546 - 1549
  • [2] A contactless surface acoustic wave biosensor
    Freudenberg, J
    Schelle, S
    Beck, K
    von Schickfus, M
    Hunklinger, S
    BIOSENSORS & BIOELECTRONICS, 1999, 14 (04): : 423 - 425
  • [3] New biosensor using shear horizontal surface acoustic wave device
    Kondoh, Jun
    Matsui, Yoshikazu
    Shiokawa, Showko
    1600, (32):
  • [4] SURFACE CONDUCTIVITY MEASUREMENTS BY A CAPACITIVE COUPLING TECHNIQUE
    DOLGOPOLOV, V
    MAZURE, C
    ZRENNER, A
    KOCH, F
    JOURNAL OF APPLIED PHYSICS, 1984, 55 (12) : 4280 - 4283
  • [5] Improvement of characteristics of leaky surface acoustic wave on LiTaO3
    Kimura, Tetsuya
    Kadota, Michio
    Ida, Yasuyuki
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2013, 96 (02) : 25 - 31
  • [6] Characteristics of liquids atomization using surface acoustic wave
    Kurosawa, M
    Futami, A
    Higuchi, T
    TRANSDUCERS 97 - 1997 INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS AND ACTUATORS, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 1997, : 801 - 804
  • [7] IMPROVEMENT OF SURFACE-ACOUSTIC-WAVE GAS SENSOR RESPONSE-TIME USING NEURAL-NETWORK PATTERN-RECOGNITION
    REBIERE, D
    BORDIEU, C
    PISTRE, J
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 25 (1-3) : 777 - 780
  • [8] NEW BIOSENSOR USING SHEAR HORIZONTAL SURFACE-ACOUSTIC-WAVE DEVICE
    KONDOH, J
    MATSUI, Y
    SHIOKAWA, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1993, 32 (5B): : 2376 - 2379
  • [9] Detection of viral bioagents using a shear horizontal surface acoustic wave biosensor
    Bisoffi, M.
    Hjelle, B.
    Brown, D. C.
    Branch, D. W.
    Edwards, T. L.
    Brozik, S. M.
    Bondu-Hawkins, V. S.
    Larson, R. S.
    BIOSENSORS & BIOELECTRONICS, 2008, 23 (09): : 1397 - 1403
  • [10] Increase in detection sensitivity of surface acoustic wave biosensor using triple transit echo wave
    Choi, Youn-Suk
    Lee, Joonhyung
    Lee, Yeolho
    Kwak, Jiwon
    Lee, Soo Suk
    APPLIED PHYSICS LETTERS, 2018, 113 (08)