Pseudophakic accommodation and pseudoaccommodation under physiological conditions measured with partial coherence interferometry

被引:39
作者
Tsorbatzoglou, Alexis
Nemeth, Gabor
Math, Janos
Berta, Andras
机构
[1] Univ Debrecen, Med & Hlth Sci Ctr, Dept Ophthalmol, H-4012 Debrecen, Hungary
[2] Univ Debrecen, Dept Psychol, H-4012 Debrecen, Hungary
关键词
D O I
10.1016/j.jcrs.2006.02.069
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To distinguish pseudophakic accommodation from pseudoaccommodation by measuring the physiologically and pharmacologically induced anterior chamber depth (ACD) shifts. SETTING: Department of Ophthalmology, University of Debrecen, Debrecen, Hungary. METHODS: This study comprised 100 pseudophakic eyes of 79 patients. Forty patients (Group 1) received the AcrySof MA60AC intraocular lens (IOL) (Alcon Laboratories), 50 patients (Group 2) received the SA60AT IOL (Alcon Laboratories), and 10 patients (Group 3) received the apodized diffractive SA60D3 ReSTOR IOL. Visual function was evaluated a mean of 10.2 months +/- 9.2 (SD) postoperatively, and the total pseudoaccommodative amplitude was determined with a defocusing technique. To distinguish pseudophakic accommodation from pseudoaccommodation, ACD measurements were performed using partial coherence interferometry during distance fixation and physiologic accommodation after pharmacologic relaxation of the ciliary muscle. RESULTS: Best corrected distance and near visual acuities were similar in the 3 groups (P =.75 and P =.08, respectively). Distance corrected near visual acuity was significantly better in Group 3 (P<.001), with all eyes achieving A or better. Three percent in Group 1 and 8% in Group 2 achieved J1 or better. Subjective accommodation was similar in Groups 1 and 2 (-0.82 +/- 0.18 diopter [D] and -1.00 +/- 0.35 D, respectively; P =.3). Group 3 had an accommodation curve with 2 peaks. Intraocular lens movement differences between the groups were not significant (physiologic stimulus: P =.07; cyclopentolate: P =.46), and significant ACD shifts from baseline were not detected (physiologic stimulus: P =.14; cyclopentolate: P =.10). CONCLUSIONS: Pseudoaccommodative amplitude of the investigated monofocal IOLs was independent of IOL movement. Anterior shift did not affect good near visual acuity with the AcrySof ReSTOR IOL.
引用
收藏
页码:1345 / 1350
页数:6
相关论文
共 29 条
[1]   SIDE-VIEW ANALYSIS OF THE LENS .2. POSITIONING OF INTRAOCULAR LENSES [J].
ASSIA, EI ;
APPLE, DJ .
ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (01) :94-98
[2]   Clinical evaluation of the model AT-45 silicone accommodating intraocular lens - Results of feasibility and the initial phase of a food and drug administration clinical trial [J].
Cumming, JS ;
Slade, SG ;
Chayet, A .
OPHTHALMOLOGY, 2001, 108 (11) :2005-2009
[3]  
Dick H Burkhard, 2005, Curr Opin Ophthalmol, V16, P8, DOI 10.1097/00055735-200502000-00004
[4]   Early visual results with the ICU accommodating intraocular lens [J].
Dogru, M ;
Honda, R ;
Omoto, M ;
Toda, I ;
Fujishima, H ;
Arai, H ;
Matsuyama, M ;
Nishijima, S ;
Hida, Y ;
Yagi, Y ;
Tsubota, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (05) :895-902
[5]  
Drexler W, 1997, INVEST OPHTH VIS SCI, V38, P1304
[6]  
Findl O, 2005, J REFRACT SURG, V21, P321
[7]   Laser interferometric assessment of pilocarpine-induced movement of an accommodating intraocular lens - A randomized trial [J].
Findl, O ;
Kriechbaum, K ;
Menapace, R ;
Koeppl, C ;
Sacu, S ;
Wirtitsch, M ;
Buehl, W ;
Drexler, W .
OPHTHALMOLOGY, 2004, 111 (08) :1515-1521
[8]   Intraocular lens movement caused by ciliary muscle contraction [J].
Findl, O ;
Kiss, B ;
Petternel, V ;
Menapace, R ;
Georgopoulos, M ;
Rainer, G ;
Drexler, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04) :669-676
[9]   High precision biometry of pseudophakic eyes using partial coherence interferometry [J].
Findl, O ;
Drexler, W ;
Menapace, R ;
Hitzenberger, CK ;
Fercher, AF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (08) :1087-1093
[10]   Relationship between apparent accommodation and corneal multifocality in pseudophakic eyes [J].
Fukuyama, M ;
Oshika, T ;
Amano, S ;
Yoshitomi, F .
OPHTHALMOLOGY, 1999, 106 (06) :1178-1181