Evaluation of the Accuracy of Aorta Scan BVI 9600 in Screening for Abdominal Aortic Aneurysm

被引:4
作者
Nguyen, A. T. V. [1 ]
Hill, G. B. [1 ]
Thomson, I. A. [1 ]
van Rij, A. M. [1 ]
机构
[1] Univ Otago, Dept Surg Sci, Dunedin Sch Med, Dunedin 9054, New Zealand
关键词
Aortic aneurysm; Ultrasound; Screening; COMPUTED-TOMOGRAPHY; INTEROBSERVER VARIABILITY; ULTRASOUND MEASUREMENTS; DIAMETER; ULTRASONOGRAPHY; SURVEILLANCE; DIFFERENCE; TROMSO; AAA;
D O I
10.1016/j.ejvs.2014.04.030
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: Despite a decreasing incidence of abdominal aortic aneurysm (AAA), the cost-effectiveness of AAA ultrasound screening can be improved by reducing the screening costs and increasing the uptake rates. The BVI 9600 (BVI) is a promising tool for this purpose as it is inexpensive and can detect AAA without a trained operator. This study aims to investigate whether the BVI can be used to detect AAA for the purpose of a low-cost outreach screening approach. Methods: A total of 142 subjects had their abdominal aortae measured by five sonographers using the BVI and a conventional ultrasound machine. The examination included four anterior-posterior measurements at four equally spaced scanning locations from the xiphisternum to the umbilicus. The measurements produced by each machine were compared using Bland-Altman plots, followed by an analysis of the AAA detection performance. Results: The BVI measured the aortic diameter to within 0.88-1.56 cm of the true diameter, exceeding the 0.5 cm "clinically acceptable difference" (CAD). Its accuracy was poorer when measuring the aneurysmal aortae (mean difference -0.56 cm, variability 1.72 cm) than normal aortae (mean difference 0.02 cm, variability 0.76 cm). Nine out of 52 aneurysms were not detected due to undersizing measurement and non-visualization of the aortae. Conclusions: At present, the BVI is not sufficiently accurate to detect AAA for screening purposes. A number of technical features require improvement. (C) 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:147 / 152
页数:6
相关论文
共 28 条
[1]   Assessment of the Accuracy of AortaScan for Detection of Abdominal Aortic Aneurysm (AAA) [J].
Abbas, A. ;
Smith, A. ;
Cecelja, M. ;
Waltham, M. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (02) :167-170
[2]   Risk Factors for Abdominal Aortic Aneurysm and the Influence of Social Deprivation [J].
Badger, Stephen A. ;
O'Donnell, Mark E. ;
Sharif, Muhammed A. ;
Boyd, Christopher S. ;
Hannon, Raymond J. ;
Lau, Louis. L. ;
Lee, Bernard ;
Soong, Chee V. .
ANGIOLOGY, 2008, 59 (05) :559-566
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
Cosford PA, 2009, COCHRANE DB SYST REV, V2
[5]   The association of obesity with abdominal aortic aneurysm presence and growth [J].
Cronin, Oliver ;
Walker, Philip J. ;
Golledge, Jonathan .
ATHEROSCLEROSIS, 2013, 226 (02) :321-327
[6]   Ultrasound surveillance of ectatic abdominal aortas [J].
Devaraj, S. ;
Dodds, S. R. .
ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2008, 90 (06) :477-482
[7]   Doubts and dilemmas over abdominal aortic aneurysm [J].
Earnshaw, J. J. .
BRITISH JOURNAL OF SURGERY, 2011, 98 (05) :607-608
[8]  
Earnshaw JJ, 2010, ULTRASOUND, V18, P167, DOI 10.1258/ult.2010.010038
[9]   LIMITATIONS OF ULTRASONOGRAPHY IN SURVEILLANCE OF SMALL ABDOMINAL AORTIC-ANEURYSMS [J].
ELLIS, M ;
POWELL, JT ;
GREENHALGH, RM .
BRITISH JOURNAL OF SURGERY, 1991, 78 (05) :614-616
[10]   Screening for abdominal aortic aneurysms using a dedicated portable ultrasound system: early results [J].
Flu, Willem-Jan ;
van Kuijk, Jan-Peter ;
Merks, Egon J. W. ;
Kuiper, Ruud ;
Verhagen, Hence J. M. ;
Bosch, Johan G. ;
Bom, Nicolaas ;
Bax, Jeroen J. ;
Poldermans, Don .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (05) :602-606