High prevalence of false-positive plateau phenomena during VO2max testing in adolescents

被引:10
作者
Beltrami, Fernando G. [1 ,2 ]
Wong, Del P. [3 ]
Noakes, Timothy D. [1 ,2 ]
机构
[1] Univ Cape Town, Dept Human Biol, ZA-7700 Rondebosch, South Africa
[2] Sports Sci Inst South Africa, Cape Town, South Africa
[3] Technol & Higher Educ Inst Hong Kong, Human Performance Lab, Hong Kong, Hong Kong, Peoples R China
关键词
Maximal oxygen consumption; Aerobic power; Aerobic test; Cardiorespiratory endurance; MAXIMAL OXYGEN-UPTAKE; GAS-ANALYSIS SYSTEMS; O-2; UPTAKE; EXERCISE; CRITERIA; RESPONSES; PROTOCOL;
D O I
10.1016/j.jsams.2013.07.012
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Objectives: It is believed that a plateau in oxygen consumption (VO2) at the end of an incremental exercise test identifies the upper limits of cardiovascular capacity. We investigated how different criteria influence the frequency with which the "plateau phenomenon" is detected and the prevalence at which "false" plateau phenomena occurs during sub-maximal exercise. Design: Cross-sectional. Methods: Six different criteria with 3 different sampling intervals each were used to identify the "plateau phenomenon" from a single data set comprising 63 incremental exercise tests along with secondary criteria based on target heart rate (HR) and respiratory exchange ratio (RER). A single criterion from the original 18 (HALF) was also used to detect the incidence of any plateau phenomena during each test. Results: The plateau phenomenon was detected in 16-82% of the tests depending on the criteria used, mostly as a result of the different sampling intervals. HALF identified 103 "plateau phenomena" but 73 (70.9%) of these occurred during sub-maximal exercise and so were "false". "False" plateaus were verified by at least one secondary criterion in 27% of cases. Participants reached the HR and RER targets after 83.6 +/- 11.7% and 81.9 +/- 18.1% of total test duration, respectively. Conclusions: The wide range in the percentage of plateau phenomena detected by different criteria plus the high rate (71%) of "false" plateau during sub-maximal exercise could indicate that this phenomenon is a calculation artifact rather than an indicator of true physiological events. Secondary criteria can be reached early in exercise and often identify "false" plateau phenomena as "true". (C) 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:526 / 530
页数:5
相关论文
共 29 条
[1]   Is peak VO2 a maximal index of children's aerobic fitness? [J].
Armstrong, N ;
Welsman, J ;
Winsley, R .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1996, 17 (05) :356-359
[2]   Peak oxygen uptake in relation to growth and maturation in 11-to 17-year-old humans [J].
Armstrong, N ;
Welsman, JR .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2001, 85 (06) :546-551
[3]  
Astorino T.A., 2000, Journal of Exercise Physiology Online, V3, P1
[4]   Performance characteristics of gas analysis systems: What we know and what we need to know [J].
Atkinson, G ;
Davison, RCR ;
Nevill, AM .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2005, 26 :S2-S10
[5]   Endurance training and aerobic fitness in young people [J].
Baquet, G ;
Van Praagh, E ;
Berthoin, S .
SPORTS MEDICINE, 2003, 33 (15) :1127-1143
[6]   Aerobic Fitness, Muscle Efficiency, and Motor Unit Recruitment during Ramp Exercise [J].
Boone, Jan ;
Koppo, Katrien ;
Barstow, Thomas J. ;
Bouckaert, Jacques .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (02) :402-408
[7]   The maximally attainable Vo2 during exercise in humans:: the peak vs. maximum issue [J].
Day, JR ;
Rossiter, HB ;
Coats, EM ;
Skasick, A ;
Whipp, BJ .
JOURNAL OF APPLIED PHYSIOLOGY, 2003, 95 (05) :1901-1907
[8]   Low frequency of the "plateau phenomenon" during maximal exercise in elite British athletes [J].
Doherty, M ;
Nobbs, L ;
Noakes, TD .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2003, 89 (06) :619-623
[9]   Applicability of VO2max criteria: Discontinuous versus continuous protocols [J].
Duncan, GE ;
Howley, ET ;
Johnson, BN .
MEDICINE & SCIENCE IN SPORTS & EXERCISE, 1997, 29 (02) :273-278
[10]  
HOWLEY ET, 1995, MED SCI SPORT EXER, V27, P1292