Experimental study on effective thermal conductivity of building insulation materials

被引:10
作者
Yan, Qiuhui [1 ]
Shen, Xuelong [1 ]
Luo, Jieren [2 ]
Yan, Han [1 ]
Gao, Hui [3 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Shaanxi, Peoples R China
[2] Xian Polytech Univ, Sch Urban Planning & Municipal Engn, Xian 710600, Shaanxi, Peoples R China
[3] Xi An Jiao Tong Univ, Sch Energy & Power Engn, MOE Key Lab Thermofluid Sci & Engn, Xian 710049, Shaanxi, Peoples R China
关键词
guarded hot plate method; effective thermal conductivity; building insulation materials; transient hot-wire method; HOT-PLATE APPARATUS; PERFORMANCE; PANELS; FLOOR;
D O I
10.1088/1361-6501/ab1890
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, effective thermal conductivity of new and high-performance building insulation materials, e.g. polystyrene board, plastic extruded board and polyurethane, is measured at a temperature range of 283-318 K, based on a guarded hot plate method. Further, measurement uncertainties are analyzed systematically. It indicates that the best measurement condition for building insulation materials is around 20 K temperature difference between hot plate and cold plate, under which an assuring uncertainty of 1% is captured. Furthermore, the measurement results are verified against open literature data and values recorded by the transient hot-wire method, and they are found to be in good agreement.
引用
收藏
页数:10
相关论文
共 30 条
  • [1] [Anonymous], HEAT TRANSM MEAS THE
  • [2] Application of the transient hot-wire technique to the measurement of the thermal conductivity of solids
    Assael, MJ
    Dix, M
    Gialou, K
    Vozar, L
    Wakeham, WA
    [J]. INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2002, 23 (03) : 615 - 633
  • [3] ASTM, 2005, STAND TEST METH STEA, pC177
  • [4] De Ponte F, 1974, HEAT TRANSMISSION ME, P97
  • [5] Degenne M, 1978, MEASUREMENT THERMAL, P130
  • [6] Intercomparison of thermal conductivity measurements on a calcium silicate insulation material
    Ebert, Hans-Peter
    Hemberger, Frank
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2011, 50 (10) : 1838 - 1844
  • [7] A steady-state high-temperature apparatus for measuring thermal conductivity of ceramics
    Filla, BJ
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (07) : 2822 - 2829
  • [8] FLYNN DR, 2005, INT THERM COND 28 C, P466
  • [9] Room temperature screening of thermal conductivity by means of thermal transient measurements
    Garcia-Canadas, Jorge
    Cheng, Shudan
    Marquez-Garcia, Lourdes
    Prest, Martin J.
    Akbari-Rahimabadi, Ahmad
    Min, Gao
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (10)
  • [10] Effect of moisture content on heat and moisture transport and storage properties of thermal insulation materials
    Jerman, Milos
    Cerny, Robert
    [J]. ENERGY AND BUILDINGS, 2012, 53 : 39 - 46