Field evaluation of HIV-1 viral load monitoring in adults and children receiving antiretroviral treatment in Nigeria by dried blood spot testing with RealTime HIV-1 on m2000

被引:4
作者
Tola, Monday [1 ]
Habib, Ramadhani O. [2 ]
Sylvia, Adebajo [3 ]
Crowell, Trevor A. [4 ,5 ]
Rebecca, Nowak G. [2 ]
Charurat, Manhattan E. [1 ,2 ]
Dakum, Patrick [1 ,2 ]
Ndembi, Nicaise [1 ,2 ,6 ,7 ]
机构
[1] Inst Human Virol Nigeria, Abuja, Federal Capital, Nigeria
[2] Univ Maryland, Sch Med, Inst Human Virol, Baltimore, MD 21201 USA
[3] Univ Maryland, Maryland Global Initiat Corp, College Pk, MD 20742 USA
[4] Henry M Jackson Fdn Adv Mil Med, Bethesda, MD USA
[5] Walter Reed Army Inst Res, US Mil HIV Res Program, Silver Spring, MD USA
[6] African Union Commiss, Africa Ctr Dis Control & Prevent Africa CDC, Addis Ababa, Ethiopia
[7] Kanazawa Univ, Grad Med Sci, Kanazawa, Ishikawa, Japan
关键词
Dried blood spot; Viral load; Antiretroviral therapy; HIV; Misclassification; VERSION; 2.0; PLASMA; ASSAY; RNA; THERAPY; QUANTIFICATION; FAILURE; AFRICA;
D O I
10.1016/j.jcv.2020.104694
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
In resource-limited settings, use of dried blood spots (DBS) could be a pragmatic alternative to plasma for VL monitoring in people living with HIV (PLWH). We compared results from DBS to standard plasma VL testing under field conditions in patients receiving antiretroviral therapy (ART). DBS cards were prepared from venous blood (V-DBS), finger-pricks using micro-capillary tubes (M-DBS), and direct spotting (D-DBS). DBS and matched EDTA plasma were tested on the Abbott m2000 platform using the appropriate RealTime HIV-1 quantitative CE protocol. Matched plasma samples were also tested on the Roche COBAS Ampliprep/COBAS TaqMan version 2.0. Diagnostic accuracy indicators (sensitivity, specificity, misclassification rate, and kappa coefficient) for viral failure (VF) based on different VL threshold levels and agreement of absolute VL were calculated. A total of 669 participants provided 2676 samples. V-DBS had a peak sensitivity for VF of 89.1 % [95 % CI: 85.5-92.7] at the 1000 copies/mL threshold and a peak specificity of 97.4 % [95 % CI: 95.9-99.0] at the 5000 copies/mL threshold. The lowest proportion of upward misclassification (patients classified with VF who actually had viral suppression) for V-DBS was 3.1 % [95 % CI: 1.4-4.8] at the 5000 copies/mL threshold, whereas the lowest proportion of downward misclassification (patients classified as undetectable who actually had VF) was 10.9 % [95 % CI: 7.2-14.5] at the 1000 copies/mL threshold. Abbott RealTime HIV-1 VL results from all 3 DBS types for adults and children showed strong correlation with the gold standard plasma-based assay. DBS could be useful for monitoring VL in resource limited settings such as Nigeria.
引用
收藏
页数:6
相关论文
共 38 条
[1]  
Abbott Molecular Inc, ABBOTT REALTIME HIV
[2]   Comparison of HIV-1 RNA Measurements Obtained by Using Plasma and Dried Blood Spots in the Automated Abbott Real-Time Viral Load Assay [J].
Arredondo, Miguel ;
Garrido, Carolina ;
Parkin, Neil ;
Zahonero, Natalia ;
Bertagnolio, Silvia ;
Soriano, Vincent ;
de Mendoza, Carmen .
JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (03) :569-572
[3]  
Bertagnolio S, 2010, AIDS REV, V12, P195
[4]   Prospective Evaluation of Diagnostic Accuracy of Dried Blood Spots from Finger Prick Samples for Determination of HIV-1 Load with the NucliSENS Easy-Q HIV-1 Version 2.0 Assay in Malawi [J].
Fajardo, Emmanuel ;
Metcalf, Carol A. ;
Chaillet, Pascale ;
Aleixo, Lucia ;
Pannus, Pieter ;
Panunzi, Isabella ;
Trivino, Laura ;
Ellman, Tom ;
Likaka, Andrew ;
Mwenda, Reuben .
JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (05) :1343-1351
[5]   Evaluation of Effect of Specimen-Handling Parameters for Plasma Preparation Tubes on Viral Load Measurements Obtained by Using the Abbott RealTime HIV-1 Load Assay [J].
Fernandes, Helen ;
Morosyuk, Svetlana ;
Abravaya, Klara ;
Ramanathan, Madhuri ;
Rainen, Lynne .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (07) :2464-2468
[6]   Cross-Platform Analysis of HIV-1 RNA Data Generated by a Multicenter Assay Validation Study with Wide Geographic Representation [J].
Jennings, Cheryl ;
Harty, Brian ;
Granger, Suzanne ;
Wager, Carrie ;
Crump, John A. ;
Fiscus, Susan A. ;
Bremer, James W. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (08) :2737-2747
[7]   Dried blood spots in HIV monitoring: applications in resource-limited settings [J].
Johannessen, Asgeir .
BIOANALYSIS, 2010, 2 (11) :1893-1908
[8]   High prevalence of HIV, chlamydia and gonorrhoea among men who have sex with men and transgender women attending trusted community centres in Abuja and Lagos, Nigeria [J].
Keshinro, Babajide ;
Crowell, Trevor A. ;
Nowak, Rebecca G. ;
Adebajo, Sylvia ;
Peel, Sheila ;
Gaydos, Charlotte A. ;
Rodriguez-Hart, Cristina ;
Baral, Stefan D. ;
Walsh, Melissa J. ;
Njoku, Ogbonnaya S. ;
Odeyemi, Sunday ;
Ngo-Ndomb, Teclaire ;
Blattner, William A. ;
Robb, Merlin L. ;
Charurat, Manhattan E. ;
Ake, Julie .
JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2016, 19
[9]   Finger Prick Dried Blood Spots for HIV Viral Load Measurement in Field Conditions in Zimbabwe [J].
Mavedzenge, Sue Napierala ;
Davey, Calum ;
Chirenje, Tarisai ;
Mushati, Phyllis ;
Mtetwa, Sibongile ;
Dirawo, Jeffrey ;
Mudenge, Boniface ;
Phillips, Andrew ;
Cowan, Frances M. .
PLOS ONE, 2015, 10 (05)
[10]   Field Evaluation of Dried Blood Spots for Routine HIV-1 Viral Load and Drug Resistance Monitoring in Patients Receiving Antiretroviral Therapy in Africa and Asia [J].
Monleau, Marjorie ;
Aghokeng, Avelin F. ;
Eymard-Duvernay, Sabrina ;
Dagnra, Anoumou ;
Kania, Dramane ;
Ngo-Giang-Huong, Nicole ;
Toure-Kane, Coumba ;
Truong, Lien X. T. ;
Chaix, Marie-Laure ;
Delaporte, Eric ;
Ayouba, Ahidjo ;
Peeters, Martine .