The quality of 3D reconstructions from 1.0 and 1.5 pitch helical and conventional CT

被引:32
作者
Hopper, KD
Pierantozzi, D
Potok, PS
Kasales, CJ
TenHave, TR
Meilstrup, JW
VanSlyke, MA
Mahraj, R
Westacott, S
Hartzel, JS
机构
[1] PENN STATE UNIV,COLL MED,HERSHEY,PA 17033
[2] PENN STATE UNIV,CTR BIOSTAT & EPIDEMIOL,HERSHEY,PA 17033
关键词
computed tomography; techniques; image display and recording;
D O I
10.1097/00004728-199609000-00036
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: CT data are commonly used to create 3D images. For this purpose, thin and overlapped slices are desirable. Helical (spiral) CT offers the ability to adjust the slice reconstruction interval from 0 to 100%. However, its use in 1.0 and 1.5 pitch helical CT and 3D imaging, especially with respect to surface detail, is relatively untested. Method: Ten objects selected for their varying size, shape, and density were scanned (fourth generation Picker PQ2000) by contiguous 2, 4, and 8 mm conventional and helical sequences. The latter were obtained with a pitch of both 1.0 and 1.5 and were reconstructed into a 3D image with 0-75% overlapping of the reconstructed slices. Each of the 24 different sequences per scanned object was reconstructed into identical sets (projections) of 3D images displayed on color film. The 24 3D image sets for each object were submitted to six blinded radiologists who separately ranked them from best to worst. Results: 3D reconstructions obtained from CT scans with a thinner slice thickness, half-field (15 cm FOV), and helical technique were rated as statistically superior. The 1.0 and 1.5 helical sequences obtained with a 4 or 8 mm slice thickness scored statistically better than 3D reconstructions from equivalent conventional scans. Overlapping of the reconstructed helical slices by 25-75% generally improved the quality of the 3D reconstruction. Conclusion: Helical CT with either a 1.0 or a 1.5 pitch offers the ability to obtain higher quality 3D reconstructions than from comparable conventional CT scans.
引用
收藏
页码:841 / 847
页数:7
相关论文
共 12 条
  • [1] DEMARINO DP, 1986, ARCH OTOLARYNGOL, V112, P146
  • [2] COLOR DISPLAY AND INTERACTIVE INTERPRETATION OF 3-DIMENSIONAL DATA
    FARRELL, EJ
    [J]. IBM JOURNAL OF RESEARCH AND DEVELOPMENT, 1983, 27 (04) : 356 - 366
  • [3] FARRELL EJ, 1989, CRIT REV BIOMED ENG, V16, P323
  • [4] 3-DIMENSIONAL RECONSTRUCTION OF CRANIOFACIAL DEFORMITY USING COMPUTED-TOMOGRAPHY
    HEMMY, DC
    DAVID, DJ
    HERMAN, GT
    [J]. NEUROSURGERY, 1983, 13 (05) : 534 - 541
  • [5] A COMPARISON OF CONVENTIONAL AND SPIRAL CT - AN EXPERIMENTAL-STUDY ON THE DETECTION OF SPHERICAL LESIONS
    KALENDER, WA
    POLACIN, A
    SUSS, C
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) : 167 - 176
  • [6] PHYSICAL PERFORMANCE-CHARACTERISTICS OF SPIRAL CT SCANNING
    KALENDER, WA
    POLACIN, A
    [J]. MEDICAL PHYSICS, 1991, 18 (05) : 910 - 915
  • [7] RECONSTRUCTED HELICAL CT SCANS - IMPROVEMENT IN Z-AXIS RESOLUTION COMPARED WITH OVERLAPPED AND NONOVERLAPPED CONVENTIONAL CT SCANS
    KASALES, CJ
    HOPPER, KD
    ARIOLA, DN
    TENHAVE, TR
    MEILSTRUP, JW
    MAHRAJ, RPM
    VANHOOK, D
    WESTACOTT, S
    SEFCZEK, RJ
    BARR, JD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (05) : 1281 - 1284
  • [8] KING SH, 1993, RADIOLOGY, V189, P356
  • [9] COMPARISON OF HELICAL AND SERIAL CT WITH REGARD TO 3-DIMENSIONAL IMAGING OF MUSCULOSKELETAL ANATOMY
    NEY, DR
    FISHMAN, EK
    KAWASHIMA, A
    ROBERTSON, DD
    SCOTT, WW
    [J]. RADIOLOGY, 1992, 185 (03) : 865 - 869
  • [10] 3-DIMENSIONAL COMPUTED-TOMOGRAPHY IN THE ASSESSMENT OF FRACTURES OF THE ACETABULUM
    WHITE, MSI
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1991, 22 (01): : 13 - 19