Transfer accuracy of 3D-printed trays for indirect bonding o orthodontic brackets: A clinical study

被引:24
作者
Bachour, Petra C. [1 ]
Klabunde, Robert [2 ]
Grunheid, Thorsten [1 ]
机构
[1] Univ Minnesota, Sch Dent, Div Orthodont, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Sch Dent, Minneapolis, MN 55455 USA
关键词
Indirect bonding; Digital; 3D printing; SYSTEM;
D O I
10.2319/073021-596.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the transfer accuracy of 3D-printed indirect bonding trays constructed using a fully digital workflow in vivo. Materials and Methods: Twenty-three consecutive patients had their incisors, canines, and premolars bonded using fully digitally designed and 3D-printed transfer trays. Intraoral scans were taken to capture final bracket positioning on teeth after bonding. Digital models of postbonding scans were superimposed on those of corresponding virtual bracket setups, and bracket positioning differences were quantified. A total of 363 brackets were evaluated. One-tailed t-tests were used to determine whether bracket positioning differences were within the limit of 0.5 mm in mesiodistal, buccolingual, and occlusogingival dimensions, and within 2 degrees for torque, tip, and rotation. Results: Mean bracket positioning differences were 0.10 mm, 0.10 mm, and 0.18 mm for mesiodistal, buccolingual, and occlusogingival measurements, respectively, with frequencies of bracket positioning within the 0.5-mm limit ranging from 96.4% to 100%. Mean differences were significantly within the acceptable limit for all linear dimensions. Mean differences were 2.55 degrees, 2.01 degrees, and 2.47 degrees for torque, tip, and rotation, respectively, with frequencies within the 2 degrees-limit ranging from 46.0% to 57.0%. Mean differences for all angular dimensions were outside the acceptable limit; however, this may have been due to limitations of scan data. Conclusions: Indirect bonding using 3D-printed trays transfers planned bracket position from the digital setup to the patient's dentition with a high positional accuracy in mesiodistal, buccolingual, and occlusogingival dimensions. Questions remain regarding the transfer accuracy for torque, tip, and rotation.
引用
收藏
页码:372 / 379
页数:8
相关论文
共 16 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Objective grading system for dental casts and panoramic radiographs [J].
Casko, JS ;
Vaden, JL ;
Kokich, VG ;
Damone, J ;
James, RD ;
Cangialosi, TJ ;
Riolo, ML ;
Owens, SE ;
Bills, ED .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1998, 114 (05) :589-599
[3]   A comparative assessment of transfer accuracy of two indirect bonding techniques in patients undergoing fixed mechanotherapy: A randomised clinical trial [J].
Chaudhary, Vivek ;
Batra, Puneet ;
Sharma, Karan ;
Raghavan, Sreevatsan ;
Gandhi, Vikram ;
Srivastava, Amit .
JOURNAL OF ORTHODONTICS, 2021, 48 (01) :13-23
[4]   Digital technology for indirect bonding [J].
Christensen, Lars R. ;
Cope, Jason B. .
SEMINARS IN ORTHODONTICS, 2018, 24 (04) :451-460
[5]   Computer-aided indirect bonding versus traditional direct bonding of orthodontic brackets: bonding time, immediate bonding failures, and cost-minimization. A randomized controlled trial [J].
Czolgosz, Izabela ;
Cattaneo, Paolo M. ;
Cornelis, Marie A. .
EUROPEAN JOURNAL OF ORTHODONTICS, 2021, 43 (02) :144-151
[6]   Transfer accuracy of vinyl polysiloxane trays for indirect bonding [J].
Gruenheid, Thorsten ;
Lee, Michael S. ;
Larson, Brent E. .
ANGLE ORTHODONTIST, 2016, 86 (03) :468-474
[7]   Effect of the presence of orthodontic brackets on intraoral scans [J].
Kang, Sung-Ja ;
Kee, Youn-Ju ;
Lee, Kyungmin Clara .
ANGLE ORTHODONTIST, 2021, 91 (01) :98-104
[8]   Accuracy of bracket positions with a CAD/CAM indirect bonding system in posterior teeth with different cusp heights [J].
Kim, Jiyeon ;
Chun, Youn-Sic ;
Kim, Minji .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2018, 153 (02) :298-307
[9]  
Koga M., 2007, Semin Orthod, V13, P11
[10]  
Layman Bill, 2019, J Clin Orthod, V53, P387