Is computed tomography attenuation correction more efficient than gated single photon emission computed tomography analysis in improving the diagnostic performance of myocardial perfusion imaging in patients with low prevalence of ischemic heart disease?

被引:5
|
作者
Benkiran, Meriem [1 ]
Mariano-Goulart, Denis [1 ]
Bourdon, Aurelie [1 ]
Sibille, Louis [2 ]
Ben Bouallegue, Faycal [1 ]
机构
[1] Lapeyronie Univ Hosp, Dept Nucl Med, F-34295 Montpellier 5, France
[2] Caremeau Univ Hosp, Dept Nucl Med, Nimes, France
关键词
attenuation correction; gated single photon emission computed tomography; myocardial perfusion imaging; single photon emission computed tomography-computed tomography; systolic wall thickening; TC-99M SESTAMIBI; CLINICAL-VALUE; SPECT; CT; ACCURACY; IMPACT; COMPENSATION; ARTIFACTS; DEFECTS; SCINTIGRAPHY;
D O I
10.1097/MNM.0000000000000218
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveThe purpose of this study was to compare computed tomography (CT)-based attenuation correction (AC) using a hybrid single photon emission computed tomography (SPECT)-CT system and quantitative analysis of wall thickening using gated SPECT with regard to the diagnostic accuracy of myocardial perfusion imaging.Materials and methodsWe prospectively included 70 patients with low prevalence of acute coronary artery disease who underwent a myocardial stress-rest SPECT study. Interpretation was based on supine nongated SPECT data with (AC) or without (NC) CT-based attenuation correction, and on gated SPECT data without attenuation correction (GNC). The scintigraphic diagnosis was obtained using standard automated quantitative analysis software and compared with a 2314 months' clinical follow-up for 57 patients or with the results of a coronary angiography for 13 patients.ResultsThe sensitivity, specificity, and overall accuracy were, respectively, 77, 60, and 63% for NC SPECT, 67, 81, and 79% for AC SPECT, and 69, 98, and 93% for GNC SPECT. The initial diagnosis was modified in about one-third of the cases for both AC and GNC, this rate being independent of any clinical parameter (including BMI) except sex (two to four times more artifact correction in men).ConclusionIts widespread availability, cost effectiveness, safety in terms of radiation exposure, and ability to significantly improve myocardial perfusion imaging specificity and accuracy make gated SPECT a self-sufficient modality for coronary artery disease screening and follow-up, whereas CT-AC should be discussed on a case-by-case basis.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 50 条
  • [31] Phase Analysis Using Gated Myocardial Perfusion Single-Photon Emission Computed Tomography Imaging for Evaluating Cardiac Dyssynchrony
    Matsuo, Shinro
    CIRCULATION JOURNAL, 2012, 76 (08) : 1832 - 1833
  • [32] Prevalence of noncardiac findings on low dose 64-slice computed tomography used for attenuation correction in myocardial perfusion imaging with SPECT
    Lars Husmann
    Fuminari Tatsugami
    Ursina Aepli
    Bernhard A. Herzog
    Ines Valenta
    Patrick Veit-Haibach
    Ronny R. Buechel
    Aju P. Pazhenkottil
    Oliver Gaemperli
    Nina Burkhard
    Christophe A. Wyss
    Philipp A. Kaufmann
    The International Journal of Cardiovascular Imaging, 2009, 25 : 859 - 865
  • [33] Incidental Detection of a Pulmonary Adenocarcinoma on Low-Dose Computed Tomography Used for Attenuation Correction in Myocardial Perfusion Imaging With SPECT
    Husmann, Lars
    Tatsugami, Fuminari
    Buechel, Ronny R.
    Pazhenkottil, Aju P.
    Kaufmann, Philipp A.
    CLINICAL NUCLEAR MEDICINE, 2010, 35 (09) : 751 - 752
  • [34] Impact of Diabetes Mellitus on Left Ventricular Synchrony by Gated Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging Phase Analysis
    Malek, Hadi
    Noveiry, Rezvaneh Saken
    Yaghoobi, Nahid
    Bakhshandeh, Hooman
    Bitarafan-Rajabi, Ahmad
    Hassanzadeh, Leila
    Hedayati, Raheleh
    IRANIAN HEART JOURNAL, 2023, 24 (01): : 54 - 61
  • [35] Evaluation of attenuation correction method for head holder in brain perfusion single-photon emission computed tomography
    Nakashima, Masahiro
    Yamazaki, Yuta
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (01) : 322 - 328
  • [36] Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease: A meta-analysis
    Valeria Cantoni
    Roberta Green
    Wanda Acampa
    Emilia Zampella
    Roberta Assante
    Carmela Nappi
    Valeria Gaudieri
    Teresa Mannarino
    Renato Cuocolo
    Eugenio Di Vaia
    Mario Petretta
    Alberto Cuocolo
    Journal of Nuclear Cardiology, 2021, 28 : 698 - 715
  • [37] Assessment of myocardial viability using single-photon emission computed tomography myocardial perfusion imaging
    Malhotra, Saurabh
    Gomez, Javier
    Doukky, Rami
    CURRENT OPINION IN CARDIOLOGY, 2019, 34 (05) : 473 - 483
  • [38] Incremental diagnostic benefit of resolution recovery software in patients with equivocal myocardial perfusion single-photon emission computed tomography (SPECT)
    Qutub, Mohammed A.
    Dowsley, Taylor
    Ali, Iftikhar
    Wells, R. Glenn
    Chen, Li
    Ruddy, Terrence D.
    Chow, Benjamin J. W.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (04) : 545 - 552
  • [39] Imaging technology for myocardial perfusion single-photon emission computed tomography 2018 in Japan
    Shibutani, Takayuki
    Okuda, Koichi
    Ichikawa, Hajime
    Kato, Toyohiro
    Miwa, Kenta
    Tsushima, Hiroyuki
    Onoguchi, Masahisa
    Nagaki, Akio
    JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (03) : 274 - 282
  • [40] The prognostic value of mechanical left ventricular dyssynchrony defined by phase analysis from gated single-photon emission computed tomography myocardial perfusion imaging among patients with coronary heart disease
    Hess, Paul L.
    Shaw, Linda K.
    Fudim, Marat
    Iskandrian, Ami E.
    Borges-Neto, Salvador
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (02) : 482 - 490