Is computed tomography attenuation correction more efficient than gated single photon emission computed tomography analysis in improving the diagnostic performance of myocardial perfusion imaging in patients with low prevalence of ischemic heart disease?

被引:5
|
作者
Benkiran, Meriem [1 ]
Mariano-Goulart, Denis [1 ]
Bourdon, Aurelie [1 ]
Sibille, Louis [2 ]
Ben Bouallegue, Faycal [1 ]
机构
[1] Lapeyronie Univ Hosp, Dept Nucl Med, F-34295 Montpellier 5, France
[2] Caremeau Univ Hosp, Dept Nucl Med, Nimes, France
关键词
attenuation correction; gated single photon emission computed tomography; myocardial perfusion imaging; single photon emission computed tomography-computed tomography; systolic wall thickening; TC-99M SESTAMIBI; CLINICAL-VALUE; SPECT; CT; ACCURACY; IMPACT; COMPENSATION; ARTIFACTS; DEFECTS; SCINTIGRAPHY;
D O I
10.1097/MNM.0000000000000218
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveThe purpose of this study was to compare computed tomography (CT)-based attenuation correction (AC) using a hybrid single photon emission computed tomography (SPECT)-CT system and quantitative analysis of wall thickening using gated SPECT with regard to the diagnostic accuracy of myocardial perfusion imaging.Materials and methodsWe prospectively included 70 patients with low prevalence of acute coronary artery disease who underwent a myocardial stress-rest SPECT study. Interpretation was based on supine nongated SPECT data with (AC) or without (NC) CT-based attenuation correction, and on gated SPECT data without attenuation correction (GNC). The scintigraphic diagnosis was obtained using standard automated quantitative analysis software and compared with a 2314 months' clinical follow-up for 57 patients or with the results of a coronary angiography for 13 patients.ResultsThe sensitivity, specificity, and overall accuracy were, respectively, 77, 60, and 63% for NC SPECT, 67, 81, and 79% for AC SPECT, and 69, 98, and 93% for GNC SPECT. The initial diagnosis was modified in about one-third of the cases for both AC and GNC, this rate being independent of any clinical parameter (including BMI) except sex (two to four times more artifact correction in men).ConclusionIts widespread availability, cost effectiveness, safety in terms of radiation exposure, and ability to significantly improve myocardial perfusion imaging specificity and accuracy make gated SPECT a self-sufficient modality for coronary artery disease screening and follow-up, whereas CT-AC should be discussed on a case-by-case basis.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 50 条
  • [21] Impact of Hypertension on the Phase Analysis Parameters of Gated Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging
    Yaghoobi, Nahid
    Araghi, Zahra Jamshidi
    Malek, Hadi
    Firoozabadi, Hasan
    Rastgou, Fereydoon
    Bakhshande, Hooman
    Rajabi, Ahmad Bitarafan
    IRANIAN HEART JOURNAL, 2019, 20 (02): : 47 - 55
  • [22] Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease: A meta-analysis
    Cantoni, Valeria
    Green, Roberta
    Acampa, Wanda
    Zampella, Emilia
    Assante, Roberta
    Nappi, Carmela
    Gaudieri, Valeria
    Mannarino, Teresa
    Cuocolo, Renato
    Di Vaia, Eugenio
    Petretta, Mario
    Cuocolo, Alberto
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (02) : 698 - 715
  • [23] Reliability of left ventricular ejection fraction calculated with gated myocardial perfusion single photon emission computed tomography in patients with extensive perfusion defect
    Harisankar, Chidambaram Natrajan Balasubramanian
    Mittal, Bhagwant Rai
    Kamaleshwaran, Koramadai Karuppuswamy
    Parmar, Madan
    Bhattacharya, Anish
    Singh, Baljinder
    Mahajan, Rajiv
    NUCLEAR MEDICINE COMMUNICATIONS, 2011, 32 (06) : 503 - 507
  • [24] Improved diagnostic accuracy of thallium-201 myocardial perfusion single-photon emission computed tomography with CT attenuation correction
    Jei-Yie Huang
    Ruoh-Fang Yen
    Wen-Chung Lee
    Chun-Kai Huang
    Pei-Ying Hsu
    Mei-Fang Cheng
    Ching-Chu Lu
    Yen-Hung Lin
    Kuo-Liong Chien
    Yen-Wen Wu
    Journal of Nuclear Cardiology, 2019, 26 : 1584 - 1595
  • [25] Influence of acquisition orbit on phase analysis of gated single photon emission computed tomography myocardial perfusion imaging for assessment of left ventricular mechanical dyssynchrony
    Misaka, Tomofumi
    Hosono, Makoto
    Kudo, Takashi
    Ito, Takamichi
    Syomura, Tsutomu
    Uemura, Masanobu
    Okajima, Kaoru
    ANNALS OF NUCLEAR MEDICINE, 2017, 31 (03) : 235 - 244
  • [26] Myocardial stunning-induced left ventricular dyssynchrony on gated single-photon emission computed tomography myocardial perfusion imaging
    Jiang, Zhixin
    Tang, Haipeng
    Shi, Jianzhou
    Zhou, Yanli
    Wang, Cheng
    Li, Dianfu
    Shan, Qijun
    Zhou, Weihua
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (08) : 725 - 731
  • [27] Diagnostic value of ventilation/perfusion single-photon emission computed tomography/computed tomography for bronchiolitis obliterans syndrome in patients after lung transplantation
    Nakashima, Masahiro
    Shinya, Takayoshi
    Oto, Takahiro
    Okawa, Tomoyo
    Takeda, Yoshihiro
    NUCLEAR MEDICINE COMMUNICATIONS, 2019, 40 (07) : 703 - 710
  • [28] Impact of ischemia on left ventricular dyssynchrony by phase analysis of gated single photon emission computed tomography myocardial perfusion imaging
    Wael AlJaroudi
    Jayanth Koneru
    Jaekyeong Heo
    Ami E. Iskandrian
    Journal of Nuclear Cardiology, 2011, 18 : 36 - 42
  • [29] Influence of myocardial count on phase dyssynchrony analysis of gated myocardial perfusion single-photon emission computed tomography
    Kita, Akinobu
    Onoguchi, Masahisa
    Shibutani, Takayuki
    Sugimoto, Katsuya
    Kosaka, Nobuyuki
    Adachi, Toshiki
    Kimura, Hirohiko
    NUCLEAR MEDICINE COMMUNICATIONS, 2019, 40 (02) : 124 - 130
  • [30] Impact of ischemia on left ventricular dyssynchrony by phase analysis of gated single photon emission computed tomography myocardial perfusion imaging
    AlJaroudi, Wael
    Koneru, Jayanth
    Heo, Jaekyeong
    Iskandrian, Ami E.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (01) : 36 - 42