Determination of biochemical parameters in human serum by near-infrared spectroscopy

被引:15
|
作者
Garcia-Garcia, J. L. [1 ]
Perez-Guaita, D. [1 ]
Ventura-Gayete, J. [2 ]
Garrigues, S. [1 ]
de la Guardia, M. [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Valencia, Spain
[2] Univ Hosp Doctor Peset, Valencia 46017, Spain
关键词
LEAST-SQUARES REGRESSION; GAMMA-GLOBULIN; GLUCOSE; CHOLESTEROL; CHEMISTRY; ALBUMIN; SYSTEM; UREA; TOOL;
D O I
10.1039/c3ay42198h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
NIR offers multiple advantages for serum analysis, permitting a fast and direct determination of several parameters simultaneously, with low sample handling and without the need for reagents during the measurement step. The aim of this paper was to provide an evaluation of this technique in a real world scale, for the simultaneous determination of several parameters and based on a considerable number of samples. Direct near infrared (NIR) absorbance measurements were used to determine the concentration of clinical parameters in human serum that are required in routine biochemical tests. Total protein, albumin, total cholesterol, high-density lipoprotein (HDL cholesterol), low-density lipoprotein (LDL cholesterol), and very low-density lipoprotein (VLDL cholesterol), triglycerides, urea and glucose were determined in 447 serum samples obtained randomly from the clinical laboratory of the University Hospital Doctor Peset in Valencia (Spain). NIR spectra from 12 500 to 4000 cm(-1) obtained with a 1 mm optical path length were evaluated by using partial least squares regression models (PLS) built from the spectra of samples with known concentrations provided by the hospital. Root mean square error cross-validation (RMSECV) was used for selecting a number of factors, spectral regions and spectral preprocessing considered to build the models, that were evaluated from their prediction capability using the relative root mean square error of prediction (RRMSEP) of a series of around 30 independent samples, not used for calibration. For some analytes such as total protein, albumin, total cholesterol and triglycerides, errors obtained were 2.3, 4.4, 5.1, and 6.2% respectively, evidencing that the proposed methodology could compete with the enzymatic reference methodologies. However in the case of urea, glucose, HDL and LDL, average errors obtained were 16.0, 16.2, 18.0 and 11.0% respectively, and therefore the NIR methodology proposed is limited as a screening tool. With the use of a considerable number of samples for calibration, this study confirms that the proposed green and cost-effective methodology is ready for scaling up from the bench to the real world.
引用
收藏
页码:3982 / 3989
页数:8
相关论文
共 50 条
  • [41] Near-infrared spectra of serum albumin and γ-globulin and determination of their concentrations in phosphate buffer solutions by partial least squares regression
    Murayama, K
    Yamada, K
    Tsenkova, R
    Wang, Y
    Ozaki, Y
    VIBRATIONAL SPECTROSCOPY, 1998, 18 (01) : 33 - 40
  • [42] Rapid Determination of Cotton Content in Textiles by Near-Infrared Spectroscopy and Interval Partial Least Squares
    Chen, Hui
    Tan, Chao
    Lin, Zan
    Wu, Tong
    ANALYTICAL LETTERS, 2018, 51 (17) : 2695 - 2707
  • [43] Rapid Determination of Cellulose, Hemicellulose and Lignin Content in Hemp Fibers Using Near-Infrared Spectroscopy
    Wang, Lijian
    Lu, Chao
    Wang, Jiangang
    Wang, Chunhong
    Li, Cuiyu
    FIBERS AND POLYMERS, 2025, : 547 - 557
  • [44] Near-Infrared Spectroscopy for the Quantitative Determination of Mass Transfer and Water Absorption Kinetics by a Polymer Solution
    Pochat-Bohatier, Celine
    Werapun, Warit
    Bouyer, Denis
    Chinpa, Watchanida
    Deratani, Andre
    JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2010, 48 (18) : 1960 - 1969
  • [45] Association of near-infrared dyes with bovine serum albumin
    Sophianopoulos, AJ
    Lipowski, J
    Narayanan, N
    Patonay, G
    APPLIED SPECTROSCOPY, 1997, 51 (10) : 1511 - 1515
  • [46] Silk Grafting with Methacrylamide: A Near-Infrared Spectroscopy Study
    Zoccola, Marina
    Boschi, Alessandra
    Arosio, Cristina
    Mossotti, Raffaella
    Innocenti, Riccardo
    Freddi, Giuliano
    JOURNAL OF APPLIED POLYMER SCIENCE, 2011, 120 (01) : 253 - 262
  • [47] Textile integrated sensors and actuators for near-infrared spectroscopy
    Zysset, Christoph
    Nasseri, Nassim
    Buethe, Lars
    Muenzenrieder, Niko
    Kinkeldei, Thomas
    Petti, Luisa
    Kleiser, Stefan
    Salvatore, Giovanni A.
    Wolf, Martin
    Troester, Gerhard
    OPTICS EXPRESS, 2013, 21 (03): : 3213 - 3224
  • [48] Determination of Total Sugar in Tobacco by Near-Infrared Spectroscopy and Wavelet Transformation-Based Calibration
    Tan, Chao
    Chen, Hui
    Wu, Tong
    Xu, Zehong
    Li, Weiyi
    Qin, Xin
    ANALYTICAL LETTERS, 2013, 46 (01) : 171 - 183
  • [49] Evaluation of nonlinear model building strategies for the determination of glucose in biological matrices by near-infrared spectroscopy
    Ding, Q
    Small, GW
    Arnold, MA
    ANALYTICA CHIMICA ACTA, 1999, 384 (03) : 333 - 343
  • [50] Modeling strategies for pharmaceutical blend monitoring and end-point determination by near-infrared spectroscopy
    Igne, Benoit
    de Juan, Anna
    Jaumot, Joaquirn
    Lallemand, Jordane
    Preys, Sebastien
    Drennen, James K.
    Anderson, Carl A.