Determination of biochemical parameters in human serum by near-infrared spectroscopy

被引:15
|
作者
Garcia-Garcia, J. L. [1 ]
Perez-Guaita, D. [1 ]
Ventura-Gayete, J. [2 ]
Garrigues, S. [1 ]
de la Guardia, M. [1 ]
机构
[1] Univ Valencia, Dept Analyt Chem, E-46100 Valencia, Spain
[2] Univ Hosp Doctor Peset, Valencia 46017, Spain
关键词
LEAST-SQUARES REGRESSION; GAMMA-GLOBULIN; GLUCOSE; CHOLESTEROL; CHEMISTRY; ALBUMIN; SYSTEM; UREA; TOOL;
D O I
10.1039/c3ay42198h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
NIR offers multiple advantages for serum analysis, permitting a fast and direct determination of several parameters simultaneously, with low sample handling and without the need for reagents during the measurement step. The aim of this paper was to provide an evaluation of this technique in a real world scale, for the simultaneous determination of several parameters and based on a considerable number of samples. Direct near infrared (NIR) absorbance measurements were used to determine the concentration of clinical parameters in human serum that are required in routine biochemical tests. Total protein, albumin, total cholesterol, high-density lipoprotein (HDL cholesterol), low-density lipoprotein (LDL cholesterol), and very low-density lipoprotein (VLDL cholesterol), triglycerides, urea and glucose were determined in 447 serum samples obtained randomly from the clinical laboratory of the University Hospital Doctor Peset in Valencia (Spain). NIR spectra from 12 500 to 4000 cm(-1) obtained with a 1 mm optical path length were evaluated by using partial least squares regression models (PLS) built from the spectra of samples with known concentrations provided by the hospital. Root mean square error cross-validation (RMSECV) was used for selecting a number of factors, spectral regions and spectral preprocessing considered to build the models, that were evaluated from their prediction capability using the relative root mean square error of prediction (RRMSEP) of a series of around 30 independent samples, not used for calibration. For some analytes such as total protein, albumin, total cholesterol and triglycerides, errors obtained were 2.3, 4.4, 5.1, and 6.2% respectively, evidencing that the proposed methodology could compete with the enzymatic reference methodologies. However in the case of urea, glucose, HDL and LDL, average errors obtained were 16.0, 16.2, 18.0 and 11.0% respectively, and therefore the NIR methodology proposed is limited as a screening tool. With the use of a considerable number of samples for calibration, this study confirms that the proposed green and cost-effective methodology is ready for scaling up from the bench to the real world.
引用
收藏
页码:3982 / 3989
页数:8
相关论文
共 50 条
  • [1] Determination of triglycerides in human serum by near-infrared diffuse reflectance spectroscopy using silver mirror as a substrate
    Wang, Shuyu
    Zhang, Jin
    Wang, Cuicui
    Yu, Xiaoming
    Cai, Wensheng
    Shao, Xueguang
    CHINESE CHEMICAL LETTERS, 2019, 30 (01) : 111 - 114
  • [2] Determination of Proteins in Human Serum by Near-Infrared Spectroscopy with Partial Least Square Analysis
    Guo, Huixian
    Huang, Furong
    Li, Yuanpeng
    Fang, Tao
    Zhu, Siqi
    Chen, Zhenqiang
    ANALYTICAL LETTERS, 2016, 49 (18) : 2964 - 2976
  • [3] Determination of human serum albumin and γ-globulin in a control serum solution by near-infrared spectroscopy and partial least squares regression
    Koichi Murayama
    Keiichi Yamada
    Roumiana Tsenkova
    Y. Wang
    Y. Ozaki
    Fresenius' Journal of Analytical Chemistry, 1998, 362 : 155 - 161
  • [4] Detecting alterations of glucose and lipid components in human serum by near-infrared Raman spectroscopy
    Biomedical Engineering Institute, Universidade Camilo Castelo Branco – Unicastelo, Parque Tecnológico de São José dos Campos, Estr. Dr. Altino Bondesan, 500, São José dos Campos
    SP
    CEP 12247-016, Brazil
    不详
    SP
    CEP 12243-003, Brazil
    Rev. Bras. Eng. Biomed., 2 (160-168): : 160 - 168
  • [5] Determination of Concentrations of Glucose and Human Serum Albumin in Mixtures in Phosphate-Buffered Solution by Near-Infrared Spectroscopy
    Ogawa, Mitsuhiro
    Yamakoshi, Takehiro
    Motoi, Kosuke
    Nishida, Koji
    Yamakoshi, Yasuhiro
    Yamakoshi, Ken-Ichi
    SENSORS AND MATERIALS, 2012, 24 (06) : 323 - 333
  • [6] Determination of total protein in hyperimmune serum samples by near-infrared spectrometry and multivariate calibration
    Baddini, Ana Luiza Q.
    da Cunha, Luiz Eduardo R.
    de Oliveira, Antonia Maria C.
    Cassella, Ricardo J.
    ANALYTICAL BIOCHEMISTRY, 2010, 397 (02) : 175 - 180
  • [7] Multivariate determination of human serum albumin and γ-globulin in a phosphate buffer solution by near infrared spectroscopy
    Murayama, K
    Yamada, K
    Tsenkova, R
    Wang, Y
    Ozaki, Y
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, 1998, : 375 - 381
  • [8] Reagentless Near-Infrared Determination Of Cholesterol In Undiluted Human Serum Using Interval Partial Least Square
    Gao, Hongzhi
    Lu, Qipeng
    Huang, Furong
    SMART MATERIALS AND NANOTECHNOLOGY IN ENGINEERING, 2012, 345 : 128 - +
  • [9] Determination of chemical composition of commercial honey by near-infrared spectroscopy
    Qiu, PY
    Ding, HB
    Tang, YK
    Xu, RJ
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1999, 47 (07) : 2760 - 2765
  • [10] Measurement of Triglycerides Concentration in Human Serum Using Near-infrared Transmission Spectroscopy and Interval PLS
    Huang, Furong
    Yu, Jianhui
    Li, Shiping
    2011 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND SYSTEMS, 2011, 8201