Outflow graft anastomosis site design could be correlated to aortic valve regurgitation under left ventricular assist device support

被引:16
作者
Iizuka, Kei [1 ]
Nishinaka, Tomohiro [1 ]
Ichihara, Yuki [1 ]
Miyamoto, Takuma [1 ]
Yamazaki, Kenji [1 ]
机构
[1] Tokyo Womens Med Univ, Dept Cardiovasc Surg, Shinjuku Ku, 8-1 Kawadacho, Tokyo, Japan
关键词
Aortic valve regurgitation; Left ventricular assist device; Heart failure; Continuous-flow; FLOW; INSUFFICIENCY; SPEED;
D O I
10.1007/s10047-017-1006-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Aortic valve regurgitation (AR) is a critical complication during circulatory support with a left ventricular assist device (LVAD). The time-course of AR and related factors, including outflow graft anastomosis site design, were investigated. Twenty-three patients who had continuous-flow LVAD implantation and were supported for more than 6 months were investigated. AR grade (none, 0; trivial, 0.5; mild, 1; mild-moderate, 1.5; moderate, 2; moderate-severe, 2.5; severe, 3) and aortic valve opening were evaluated with echocardiography. Computed tomography was performed to all the patients postoperatively. The angle of the outflow graft to the aorta (O-A angle, parallel 0; tangent 90A degrees, 0-180A degrees), aortic diameter at the anastomosis site, sino-tubular junction (STJ) diameter, distance between the STJ and the anastomosis site, and distance between the anastomosis site and the brachiocephalic artery were measured. The patients' age was 38 +/- 11 years. Support duration was 686 +/- 354 days. Mean AR grade after continuous-flow LVAD implantation was increased to around mild and was maintained thereafter. No patient needed any intervention to the aortic valve. The aortic valves of 82.6% of patients were closed continuously. The O-A angle (83 +/- 14) was positively correlated with maximum AR grade (p = 0.0095). The O-A angle was significantly smaller in patients with maximum AR grade of 1 or less (77 +/- 9A degrees) than in those with 1.5 or greater (94 +/- 15A degrees, p = 0.021). The other CT measurements had no correlation with AR grade. In conclusion, the O-A angle was correlated with AR grade progression. The O-A angle appears to be one of the important factors related to AR under continuous-flow LVAD support.
引用
收藏
页码:150 / 155
页数:6
相关论文
共 50 条
[21]   Influence of the Outflow Graft Angular Position on the Outcomes in Patients With a Left Ventricular Assist Device [J].
Zijderhand, Casper F. ;
Peek, Jette J. ;
Sjatskig, Jelena ;
Manintveld, Olivier C. ;
Bekkers, Jos A. ;
Bogers, Ad J. J. C. ;
Caliskan, Kadir .
ASAIO JOURNAL, 2024, 70 (10) :861-867
[22]   Natural history and clinical effect of aortic valve regurgitation after left ventricular assist device implantation [J].
Rajagopal, Keshava ;
Daneshmand, Mani A. ;
Patel, Chetan B. ;
Ganapathi, Asvin M. ;
Schechter, Matthew A. ;
Rogers, Joseph G. ;
Milano, Carmelo A. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (05) :1373-1379
[23]   Transcatheter aortic valve replacement for left ventricular assist device-related aortic regurgitation and prohibitive surgical risk: a case report [J].
Barragan-Amado, Andres F. ;
Manzur Barbur, Maria ;
Holguin, Diego ;
Obando, Carlos ;
Rodriguez-Gonzalez, Maria J. .
EUROPEAN HEART JOURNAL-CASE REPORTS, 2025, 9 (02)
[24]   Left Ventricular Assist Device Performance Under Pressure Troubleshooting Outflow Graft Dysfunction [J].
Belkin, Mark N. ;
Venturini, Joseph ;
Nathan, Sandeep ;
Grinstein, Jonathan .
CIRCULATION-HEART FAILURE, 2020, 13 (07)
[25]   Direct aortic transcatheter aortic valve implantation for pure aortic valve regurgitation after implantation of a left ventricular assist device [J].
Krause, Rene ;
Metz, Dietrich ;
Bushnaq, Hasan .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 147 (04) :E38-E41
[26]   In Vitro Analysis of Left Ventricular Assist Device Outflow Graft Orientations and Their Effect on Aortic Hemodynamics [J].
Herz, Christopher ;
Grab, Maximilian ;
Mueller, Christoph ;
Hanuna, Maja ;
Kamla, Christine-Elena ;
Clevert, Dirk-Andre ;
Curta, Adrian ;
Fink, Nicola ;
Mela, Petra ;
Hagl, Christian ;
Grefen, Linda .
ASAIO JOURNAL, 2025, 71 (06) :445-453
[27]   Left Ventricular Assist Device Support-Induced Alteration of Mechanical Stress on Aortic Valve and Aortic Wall [J].
Kainuma, Atsushi ;
Itatani, Keiichi ;
Hayashi, Hideyuki ;
Kaku, Yuji ;
Wu, Isaac Y. ;
Colombo, Paolo C. ;
Ferrari, Giovanni ;
Kurlansky, Paul ;
Yuzefpolskaya, Melana ;
Takeda, Koji ;
Naka, Yoshifumi ;
Akiyama, Koichi ;
Takayama, Hiroo .
ASAIO JOURNAL, 2022, 68 (04) :516-523
[28]   Resolution of Mitral Regurgitation With Left Ventricular Assist Device Support [J].
Goodwin, Matthew ;
Nemeh, Hassan W. ;
Borgi, Jamil ;
Paone, Gaetano ;
Morgan, Jeffrey A. .
ANNALS OF THORACIC SURGERY, 2017, 104 (03) :811-819
[29]   Concomitant Transcatheter Aortic Valve and Left Ventricular Assist Device Implantation [J].
Baum, Christina ;
Seiffert, Moritz ;
Treede, Hendrik ;
Reichenspurner, Hermann ;
Deuse, Tobias .
ASAIO JOURNAL, 2013, 59 (01) :90-92
[30]   Reciprocal interferences of the left ventricular assist device and the aortic valve competence [J].
Vriz, Olga ;
Mushtaq, Ali ;
Shaik, Abdullah ;
El-Shaer, Ahmed ;
Feras, Khalid ;
Eltayeb, Abdalla ;
Alsergnai, Hani ;
Kholaif, Naji ;
Al Hussein, Mosaad ;
Albert-Brotons, Dimpna ;
Simon, Andre Rudiger ;
Tsai, Felix Wang .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 9