Outflow graft anastomosis site design could be correlated to aortic valve regurgitation under left ventricular assist device support

被引:16
作者
Iizuka, Kei [1 ]
Nishinaka, Tomohiro [1 ]
Ichihara, Yuki [1 ]
Miyamoto, Takuma [1 ]
Yamazaki, Kenji [1 ]
机构
[1] Tokyo Womens Med Univ, Dept Cardiovasc Surg, Shinjuku Ku, 8-1 Kawadacho, Tokyo, Japan
关键词
Aortic valve regurgitation; Left ventricular assist device; Heart failure; Continuous-flow; FLOW; INSUFFICIENCY; SPEED;
D O I
10.1007/s10047-017-1006-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Aortic valve regurgitation (AR) is a critical complication during circulatory support with a left ventricular assist device (LVAD). The time-course of AR and related factors, including outflow graft anastomosis site design, were investigated. Twenty-three patients who had continuous-flow LVAD implantation and were supported for more than 6 months were investigated. AR grade (none, 0; trivial, 0.5; mild, 1; mild-moderate, 1.5; moderate, 2; moderate-severe, 2.5; severe, 3) and aortic valve opening were evaluated with echocardiography. Computed tomography was performed to all the patients postoperatively. The angle of the outflow graft to the aorta (O-A angle, parallel 0; tangent 90A degrees, 0-180A degrees), aortic diameter at the anastomosis site, sino-tubular junction (STJ) diameter, distance between the STJ and the anastomosis site, and distance between the anastomosis site and the brachiocephalic artery were measured. The patients' age was 38 +/- 11 years. Support duration was 686 +/- 354 days. Mean AR grade after continuous-flow LVAD implantation was increased to around mild and was maintained thereafter. No patient needed any intervention to the aortic valve. The aortic valves of 82.6% of patients were closed continuously. The O-A angle (83 +/- 14) was positively correlated with maximum AR grade (p = 0.0095). The O-A angle was significantly smaller in patients with maximum AR grade of 1 or less (77 +/- 9A degrees) than in those with 1.5 or greater (94 +/- 15A degrees, p = 0.021). The other CT measurements had no correlation with AR grade. In conclusion, the O-A angle was correlated with AR grade progression. The O-A angle appears to be one of the important factors related to AR under continuous-flow LVAD support.
引用
收藏
页码:150 / 155
页数:6
相关论文
共 12 条
[1]   Effect of cannula position in the thoracic aorta with continuous left ventricular support: four-dimensional flow-sensitive magnetic resonance imaging in an in vitro model [J].
Benk, Christoph ;
Mauch, Alexander ;
Beyersdorf, Friedhelm ;
Klemm, Rolf ;
Russe, Maximilian ;
Blanke, Philipp ;
Korvink, Jan G. ;
Markl, Michael ;
Jung, Bernd .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 44 (03) :551-558
[2]   The Development of Aortic Insufficiency in Left Ventricular Assist Device-Supported Patients [J].
Cowger, Jennifer ;
Pagani, Francis D. ;
Haft, Jonathan W. ;
Romano, Matthew A. ;
Aaronson, Keith D. ;
Kolias, Theodore J. .
CIRCULATION-HEART FAILURE, 2010, 3 (06) :668-674
[3]   Less Frequent Opening of the Aortic Valve and a Continuous Flow Pump Are Risk Factors for Postoperative Onset of Aortic Insufficiency in Patients With a Left Ventricular Assist Device [J].
Hatano, Masaru ;
Kinugawa, Koichiro ;
Shiga, Taro ;
Kato, Naoko ;
Endo, Miyoko ;
Hisagi, Motoyuki ;
Nishimura, Takashi ;
Yao, Atsushi ;
Hirata, Yasunobu ;
Kyo, Shunei ;
Ono, Minoru ;
Nagai, Ryozo .
CIRCULATION JOURNAL, 2011, 75 (05) :1147-1155
[4]   The influence of pump rotation speed on hemodynamics and myocardial oxygen metabolism in left ventricular assist device support with aortic valve regurgitation [J].
Iizuka, Kei ;
Nishinaka, Tomohiro ;
Takewa, Yoshiaki ;
Yamazaki, Kenji ;
Tatsumi, Eisuke .
JOURNAL OF ARTIFICIAL ORGANS, 2017, 20 (03) :194-199
[5]   Effect of LVAD Outlet Graft Anastomosis Angle on the Aortic Valve, Wall, and Flow [J].
Inci, Gizem ;
Sorguven, Esra .
ASAIO JOURNAL, 2012, 58 (04) :373-381
[6]   Central aortic valve closure successfully treated aortic insufficiency of the patient with Jarvik 2000 continuous flow left ventricular assist device: a case report [J].
Itoda, Yoshifumi ;
Nawata, Kan ;
Yamauchi, Haruo ;
Kinoshita, Osamu ;
Kimura, Mitsutoshi ;
Ono, Minoru .
JOURNAL OF ARTIFICIAL ORGANS, 2017, 20 (01) :99-101
[7]   Investigation of the freely available easy-to-use software 'EZR' for medical statistics [J].
Kanda, Y. .
BONE MARROW TRANSPLANTATION, 2013, 48 (03) :452-458
[8]   Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta [J].
May-Newman, K ;
Hillen, B ;
Dembitsky, W .
ASAIO JOURNAL, 2006, 52 (02) :132-139
[9]   Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices [J].
Pak, Sang-Woo ;
Uriel, Nir ;
Takayama, Hiroo ;
Cappleman, Sarah ;
Song, Robert ;
Colombo, Paolo C. ;
Charles, Sandy ;
Mancini, Donna ;
Gillam, Linda ;
Naka, Yoshifumi ;
Jorde, Ulrich P. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (10) :1172-1176
[10]   De Novo Aortic Regurgitation After Continuous-Flow Left Ventricular Assist Device Implantation [J].
Patil, Nikhil Prakash ;
Sabashnikov, Anton ;
Mohite, Prashant N. ;
Garcia, Diana ;
Weymann, Alexander ;
Zych, Bartlomiej ;
Bowles, Christopher T. ;
Hards, Rachel ;
Hedger, Michael ;
Popov, Aron F. ;
De Robertis, Fabio ;
Moza, Ajay ;
Bahrami, Toufan ;
Amrani, Mohamed ;
Rahman-Haley, Shelley ;
Banner, Nicholas R. ;
Simon, Andre Ruediger .
ANNALS OF THORACIC SURGERY, 2014, 98 (03) :850-857