Optimization Research on Grounding Resistance of Power Transmission Line Tower Foundation

被引:0
|
作者
Xiang, Zhen [1 ]
Li, Xun [1 ]
Chen, Xiao [1 ]
Lv, Qishen [1 ]
Zhang, Chengwei [1 ]
Ai, Jingwen [1 ]
机构
[1] Shenzhen Power Supply Co Ltd, Shenzhen 518000, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Tower Foundation; Flexible Plane Composite Grounding Material; Natural Grounding; Tower Foundation External Application; Resistance Reduction Efficiency;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Improving the current divergence characteristics of the tower foundation can effectively reduce the tower grounding resistance and reduce the cost of secondary artificial grounding. At present, it is necessary to further study the grounding of the tower foundation. In this paper, the finite element simulation software COMSOL is used to build single-pile concrete foundation simulation models and multi-pile concrete foundation simulation models. Five kinds of tower foundation external resistance reduction methods based on flexible planar composite grounding materials are proposed, such as full-laying, lower-half-laying, upper-laying, middle-laying and lower-laying. The effects of external radius, tower depth and groundwater layer position on grounding resistance are investigated. The effects of the aquifer on the current density distribution are compared. The effects of aquifers on current density distribution and the effects of three multi-pile resistance reduction schemes on ground potential and current density are compared. The simulation results show that increasing the external radius and tower depth is beneficial to improve the efficiency of reducing the resistance. From the big to the small, the efficiency of resistance reduction by external application of pile-by-pile is full application, lower half application, lower, middle and upper. The aquifer reduces the grounding resistance of the foundation, and when the aquifer is closer to the surface, the effect of reducing the resistance is more obvious. When the multi-pile foundation with higher voltage level adopts external application to reduce resistance, the efficiency of external application of ring wrap is higher than that of pile-by-pile application. The conclusions of this paper can provide reference for the actual transmission line design and lightning protection grounding construction.
引用
收藏
页码:82 / 86
页数:5
相关论文
共 50 条
  • [1] METHOD OF ESTIMATING THE GROUNDING RESISTANCE OF POWER TRANSMISSION TOWER FOUNDATION.
    Noda, Masanobu
    Kinoshita, Hitoshi
    Matsubara, Ichiro
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1987, 107 (04): : 68 - 76
  • [2] Simulation and Structure Optimization of Grounding Circuit Model for Power Transmission Line Tower
    Hu, Yuanchao
    Cheng, Yan
    Jiang, Zhipeng
    An, Yunzhu
    Jeon, Seunggil
    Zhou, Wen
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2022, 31 (16)
  • [3] Structural Optimization of UHV Transmission Line Tower Foundation With External Flexible Graphite Composite Grounding Material
    Li, Xun
    Xiang, Zhen
    Lv, Qishen
    Liu, Shungui
    Ai, Jingwen
    Chen, Xiao
    2019 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT GREEN BUILDING AND SMART GRID (IGBSG 2019), 2019, : 87 - 91
  • [4] Research on Soft Grounding Material with High Conductivity in Transmission Line Tower Grounding Network
    Wu Guoliang
    Luo Yongqin
    2016 2ND INTERNATIONAL CONFERENCE ON MECHANICAL, ELECTRONIC AND INFORMATION TECHNOLOGY ENGINEERING (ICMITE 2016), 2016, : 346 - 350
  • [5] Algorithm Research on Tower Grounding Resistance On-line Measurement
    Wang, Tao
    Li, Bing
    Yang, Hongxing
    MEASUREMENT TECHNOLOGY AND ITS APPLICATION, PTS 1 AND 2, 2013, 239-240 : 372 - 375
  • [6] Calculation and analysis of grounding body of typical tower foundation for UHV power transmission
    Pan, Wenxia
    Wang, Bing
    Quan, Rui
    Dai, Min
    Tong, Xuefang
    Gu, Dingxie
    Dianwang Jishu/Power System Technology, 2013, 37 (03): : 679 - 685
  • [7] Power Frequency Interference and Suppression in Measurement of Power Transmission Tower Grounding Resistance
    Zhou, Wenjun
    Liu, Yushun
    Li, Gongxin
    Yan, Guozhi
    Yang, Shuai
    Li, Han
    Zhou, Chengke
    Su, Charles Qi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (02) : 1016 - 1023
  • [8] Research on New Grounding Technology of Transmission Line Tower in Karst Area
    Liu, Sanwei
    Sima, Wenxia
    Yuan, Tao
    Yang, Qing
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1154 - 1157
  • [9] Quick calculation of the grounding resistance of a typical 110 kV transmission line tower grounding system
    Trifunovic, J.
    Kostic, M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 131 : 178 - 186
  • [10] ECONOMIC OPTIMIZATION OF TRANSMISSION TOWER GROUNDING AND INSULATION
    GROSSER, GE
    HILEMAN, AR
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1967, PA86 (08): : 979 - &