Determination of Cl, Br and I in granola: Development of an accurate analytical method using ICP-MS

被引:9
作者
Druzian, Gabriel T. [1 ]
Nascimento, Mariele S. [1 ]
Cerqueira, Uillian M. F. M. [2 ,3 ]
Novaes, Cleber G. [2 ]
Bezerra, Marcos A. [2 ]
Duarte, Fabio A. [1 ]
Flores, Erico M. M. [1 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
[2] Univ Estadual Sudoeste Bahia, Dept Ciencias & Tecnol, BR-45208409 Jequie, BA, Brazil
[3] Univ Fed Bahia, Dept Quim Analit, Inst Quim, Campus Univ Ondina, BR-40170115 Salvador, BA, Brazil
关键词
Halogen determination; Granola analysis; Microwave-induced combustion; Sample preparation; Food analysis; ICP-MS; PLASMA-MASS SPECTROMETRY; DILUTED ACID DIGESTION; IODINE DETERMINATION; HALOGEN DETERMINATION; TOXIC ELEMENTS; BROMINE; CHROMATOGRAPHY; CHLORINE; MATRICES; FOOD;
D O I
10.1016/j.foodchem.2020.128677
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Microwave-induced combustion (MIC) system for further Cl, Br, and I determination in granola by inductively coupled plasma mass spectrometry (ICP-MS) was proposed. A high sample mass of granola was pressed as pellets and inserted into the proposed MIC system. Water and NH4OH were evaluated as absorbing solutions. The accuracy was estimated by the analysis of two certified reference materials and also by spike recoveries. Using the optimized conditions (zirconium ball milling, 1 g of granola and 6 mL of 50 mmol L-1NH4OH), the agreement with the certified values ranged from 94 to 98% and recoveries higher than 95% were obtained. Low carbon concentration in digests (<25 mg L-1) was achieved, minimizing interferences by ICP-MS. Blanks were negligible and only diluted solutions were required. The concentration in samples ranged from 322 to 896, 0.618 to 0.980 and < 0.002 to 0.181 mu g g(-1) for Cl, Br and I, respectively.
引用
收藏
页数:7
相关论文
共 40 条
[1]  
[Anonymous], 2007, Assessment of Iodine Deficiency Disorders and Monitoring Their Elimination: A Guide for Programme Managers
[2]  
Arendt EK., 2013, CEREAL GRAINS FOOD B
[3]  
Arruda MAZ., 2007, TRENDS SAMPLE PREPAR
[4]   Microwave-assisted diluted acid digestion for trace elements analysis of edible soybean products [J].
Barbosa, Jose Tiago P. ;
Santos, Clarissa M. M. ;
Peralva, Vanessa N. ;
Flores, Eric M. M. ;
Korn, Mauro ;
Nobrega, Joaquim A. ;
Korn, Maria Gracas A. .
FOOD CHEMISTRY, 2015, 175 :212-217
[5]  
Corke H., 2016, ENCY FOOD GRAINS, P41
[6]   Rare earth element determination in heavy crude oil by USN-ICP-MS after digestion using a microwave-assisted single reaction chamber [J].
Druzian, Gabriel T. ;
Pereira, Leticia S. F. ;
Mello, Paola A. ;
Mesko, Marcia F. ;
Duarte, Fabio A. ;
Flores, Erico M. M. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (06) :1185-1191
[7]  
Eurachem, 1998, EUR FITN PURP AN MET
[8]   TRACE ANALYSIS IN HIGH MATRIX AQUEOUS-SOLUTIONS USING HELIUM MICROWAVE-INDUCED PLASMA-MASS SPECTROMETRY [J].
FECHER, PA ;
NAGENGAST, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (09) :1021-1027
[9]   The effects of organic and conventional fertilizers on cereal aphids and their natural enemies [J].
Garratt, Michael P. D. ;
Wright, Denis J. ;
Leather, Simon R. .
AGRICULTURAL AND FOREST ENTOMOLOGY, 2010, 12 (03) :307-318
[10]   A systematic study on the influence of carbon on the behavior of hard-to-ionize elements in inductively coupled plasma-mass spectrometry [J].
Grindlay, Guillermo ;
Mora, Juan ;
de Loos-Vollebregt, Margaretha ;
Vanhaecke, Frank .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 86 :42-49