The effect of decreasing digital image resolution on teledermatology diagnosis

被引:23
作者
Vidmar, DA
Cruess, D
Hsieh, P
Dolecek, Q
Pak, H
Gwynn, M
Maggio, K
Montemorano, A
Powers, J
Richards, D
Sperling, L
Wong, H
Yeager, J
机构
[1] Uniformed Serv Univ Hlth Sci, Dept Mil & Emergency Med & Dermatol, Bethesda, MD 20814 USA
[2] Uniformed Serv Univ Hlth Sci, Dept Prevent Med & Biometr, Bethesda, MD 20814 USA
[3] Uniformed Serv Univ Hlth Sci, Dept Dermatol, Bethesda, MD 20814 USA
[4] Uniformed Serv Univ Hlth Sci, Casualty Care Res Ctr, Bethesda, MD 20814 USA
[5] Johns Hopkins Univ, Appl Phys Lab, Inst Adv Sci & Technol Med, Laurel, MD USA
[6] Walter Reed Army Inst Res, Silver Spring, MD USA
来源
TELEMEDICINE JOURNAL | 1999年 / 5卷 / 04期
关键词
D O I
10.1089/107830299311943
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objective: To determine the effect of degraded digital image resolution (as viewed on a monitor) on the accuracy and confidence of dermatologic interpretation. Materials and Methods: Eight dermatologists interpreted 180 clinical cases divided into three Logical Competitor Sets (LCS) (pigmented lesions, non-pigmented lesions, and inflammatory dermatoses). Each case was digitized at three different resolutions. The images were randomized and divided into (9) 60-image sessions. The physicians were completely blinded concerning the image resolution. After 60 seconds per image, the viewer recorded a diagnosis and level of confidence. The resultant ROC curves compared the effect of LCS, level of clinical difficulty, and resolution of the digital image. One-way analysis of variance (ANOVA) compared the curves. Results: The areas beneath the ROC curves did not demonstrate any consistently significant difference between the digital image resolutions for all LCS and levels of difficulty. The only significant effect observed was amongst pigmented lesions (LCS-A) where the ROC curve area was significantly smaller in the easy images at high resolution compared to low and medium resolutions. For all other ROC curve comparisons within LCS-A, at all other levels of difficulty, as well as within the other LCS at all levels of difficulty, none of the differences was significant. Conclusion: A 720 x 500 pixel image can be considered equivalent to a 1490 x 1000 pixel image for most store-and-forward teledermatology consultations.
引用
收藏
页码:375 / 383
页数:9
相关论文
共 9 条
[1]   Resolution requirements for digital images in dermatology [J].
Bittorf, A ;
Fartasch, M ;
Schuler, G ;
Diepgen, TL .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1997, 37 (02) :195-198
[2]   RADIOGRAPHIC APPLICATIONS OF RECEIVER OPERATING CHARACTERISTIC (ROC) CURVES [J].
GOODENOUGH, DJ ;
ROSSMANN, K ;
LUSTED, LB .
RADIOLOGY, 1974, 110 (01) :89-95
[3]   WHAT DERMATOLOGISTS SHOULD KNOW ABOUT DIGITAL IMAGING [J].
PEREDNIA, DA .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1991, 25 (01) :89-108
[4]   VARIABILITY IN PHYSICIAN ASSESSMENT OF LESIONS IN CUTANEOUS IMAGES AND ITS IMPLICATIONS FOR SKIN SCREENING AND COMPUTER-ASSISTED DIAGNOSIS [J].
PEREDNIA, DA ;
GAINES, JA ;
ROSSUM, AC .
ARCHIVES OF DERMATOLOGY, 1992, 128 (03) :357-364
[5]   COMPARISON OF THE CLINICAL INFORMATIVENESS OF PHOTOGRAPHS AND DIGITAL IMAGING MEDIA WITH MULTIPLE-CHOICE RECEIVER OPERATING CHARACTERISTIC ANALYSIS [J].
PEREDNIA, DA ;
GAINES, JA ;
BUTRUILLE, TW .
ARCHIVES OF DERMATOLOGY, 1995, 131 (03) :292-297
[6]  
Reiter E, 1996, Telemed J, V2, P131, DOI 10.1089/tmj.1.1996.2.131
[7]  
SCHNEIDERMAN C, 1994, COMPUT MED IMAG GRAP, V18, P339
[8]  
Sneiderman C A, 1991, J Biocommun, V18, P22
[9]   ROC ANALYSIS APPLIED TO THE EVALUATION OF MEDICAL IMAGING TECHNIQUES [J].
SWETS, JA .
INVESTIGATIVE RADIOLOGY, 1979, 14 (02) :109-121