Embolization of peripheral high-flow arteriovenous malformations with Onyx

被引:41
作者
Kilani, M. Saeed [1 ,2 ]
Lepennec, V. [3 ]
Petit, P. [4 ]
Magalon, G. [5 ]
Casanova, D. [5 ]
Bartoli, J. -M. [4 ]
Vidal, V. [4 ]
机构
[1] CHR Lille, Serv Radiol, Hop Cardiol, Blvd Pr Jules Leclercq, F-59037 Lille, France
[2] Suez Canal Univ Hosp, Dept Radiol, Ring Rd, Ismailia 41511, Egypt
[3] CHU Caen, Serv Radiol, Ave Cote De Nacre, F-14033 Caen 9, France
[4] CHU Marseille, Hop Timone, Serv Radiol, 264 Rue Saint Pierre, F-13385 Marseille 05, France
[5] CHU Marseille, Hop Concept, Serv Chirurg Reparatrice, 264 Rue Saint Pierre, F-13385 Marseille 05, France
关键词
Embolization; AVM; Ethyl vinyl alcohol copolymer (Onyx); VINYL ALCOHOL COPOLYMER; LIQUID EMBOLIC AGENT; VASCULAR MALFORMATIONS; SINGLE-CENTER; SWINE; COMPLICATIONS; EXPERIENCE; MANAGEMENT; OCCLUSION; ANEURYSMS;
D O I
10.1016/j.diii.2016.06.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to report our experience in embolization of high flow peripheral arteriovenous malformations (AVMs) with Onyx. Material and methods: Nineteen patients (10 men, 9 women) with peripheral high-flow AVMs who were treated with arteruial embolization using Onyx were retrospectively included. AVMs were located in the head and neck (6), extremities (5), chest (2), kidney (2), uterus (2), pelvis (1) and parietal (1). In 13 patients, embolization was done using Onyx only. One patient underwent embolization by direct puncture, the others by transarterial approach. Embolization was performed in one or multiple sessions (up to 5). A total of 28 sessions were performed. Follow-up was performed with a delay between 10 and 34 months. Results: Technical success was achieved in all patients. Complete devascularization was obtained in 12 patients. Surgical excision was performed in 9 patients. Non-target Onyx embolization was not observed. One patient developed stroke. In 1 patient microcatheter fracture occured. One patient presented severe pain and bradycardia during the procedure that disappeared shortly after. One patient had persistent but less frequent epistaxis after embolization. Another patient had persistent pain without improvement. One patient was lost to follow-up. Other patients were free of symptoms on follow-up. Conclusions: Embolization with Onyx((R)) is an interesting option for management of peripheralhighflow AVMs either preoperatively or as a single treatment. (C) 2016 Editions francaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:216 / 225
页数:10
相关论文
共 36 条
[1]   Surgical handling characteristics of an ethylene vinyl alcohol copolymer compared with N-butyl cyanoacrylate used for embolization of vessels in an arteriovenous malformation resection model in swine [J].
Akin, ED ;
Perkins, E ;
Ross, IB .
JOURNAL OF NEUROSURGERY, 2003, 98 (02) :366-370
[2]   ABC OF VASCULAR DISEASES - PERIPHERAL ARTERIOVENOUS-MALFORMATIONS [J].
ALLISON, DJ ;
KENNEDY, A .
BRITISH MEDICAL JOURNAL, 1991, 303 (6811) :1191-1194
[3]   Embolization of high-flow craniofacial vascular malformations with onyx [J].
Arat, A. ;
Cil, B. E. ;
Vargel, I. ;
Turkbey, B. ;
Canyigit, M. ;
Peynircioglu, B. ;
Arat, Y. O. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (07) :1409-1414
[4]   Onyx®:: a unique neuroembolic agent [J].
Ayad, Michael ;
Eskioglu, Eric ;
Mericle, Robert A. .
EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (06) :705-715
[5]   Endovascular embolization of visceral artery aneurysms with ethylene-vinyl alcohol (Onyx): A case series [J].
Bratby, M. J. ;
Lehmann, E. D. ;
Bottomley, J. ;
Kessel, D. O. ;
Nicholson, A. A. ;
McPherson, S. J. ;
Morgan, R. A. ;
Belli, A. -M. .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (06) :1125-1128
[6]   The use of Onyx for embolization of peripheral vascular malformations in pediatric patients [J].
Cantasdemir, Murat ;
Gulsen, Fatih ;
Solak, Serdar ;
Gulsen, Gokce Yalcin ;
Kantarci, Fatih ;
Numan, Furuzan .
PEDIATRIC SURGERY INTERNATIONAL, 2012, 28 (05) :477-487
[7]   Treatment of pelvic arteriovenous malformations with ethylene vinyl alcohol copolymer (Onyx) [J].
Castaneda, F ;
Goodwin, SC ;
Swischuk, JL ;
Wong, GCH ;
Bonilla, SM ;
Wang, MJ ;
Abdel-Sayed, PS .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (05) :513-516
[8]  
Chaloupka JC, 1999, AM J NEURORADIOL, V20, P401
[9]   Combined Endovascular and Surgical Approach for the Treatment of Palpebral Arteriovenous Malformations: Experience of a Single Center [J].
Clarencon, F. ;
Blanc, R. ;
Lin, C. -J. ;
Mounayer, C. ;
Galatoire, O. ;
Morax, S. ;
Moret, J. ;
Piotin, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (01) :148-153
[10]  
Debrun G M, 1997, Interv Neuroradiol, V3, P13