Inappropriate implantable defibrillator discharges from lead failure

被引:0
|
作者
Hiew, Chin V. [1 ]
Leitch, James W. [1 ]
机构
[1] John Hunter Hosp, Cardiovasc Dept, Newcastle, NSW, Australia
关键词
D O I
10.5694/j.1326-5377.2009.tb02290.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:97 / 98
页数:2
相关论文
共 50 条
  • [31] Implantable cardioverter-defibrillator lead failure: how weak is the link?
    Brinker, Jeffrey A.
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (12): : 758 - 759
  • [32] Failure of implantable cardioverter-defibrillator leads: A matter of lead size?
    Rordorf, Roberto
    Poggio, Luca
    Savastano, Simone
    Vicentini, Alessandro
    Petracci, Barbara
    Chieffo, Enrico
    Klersy, Catherine
    Landolina, Maurizio
    HEART RHYTHM, 2013, 10 (02) : 184 - 190
  • [33] Implantable Cardioverter-Defibrillator Lead Failure in Children and Young Adults
    Janson, Christopher M.
    Patel, Akash R.
    Bonney, William J.
    Smoots, Karen
    Shah, Maully J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (02) : 133 - 140
  • [34] Long-term Outcome of Implantable Cardioverter/Defibrillator Lead Failure
    Davidsson, Gustav Arnar
    Jonsdottir, Gudlaug M.
    Oddsson, Hjortur
    Lund, Sigrun H.
    Arnar, David O.
    JAMA INTERNAL MEDICINE, 2020, 180 (02) : 322 - 324
  • [35] Implantable cardioverter-defibrillator lead failure: how weak is the link?
    Jeffrey A Brinker
    Nature Clinical Practice Cardiovascular Medicine, 2008, 5 : 758 - 759
  • [36] Subcutaneous Implantable Cardioverter Defibrillator Lead Failure due to Twiddler Syndrome
    Kooiman, Kirsten M.
    Brouwer, Tom F.
    Van Halm, Vokko P.
    Knops, Reinoud E.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (11): : 1369 - 1371
  • [37] INAPPROPRIATE RECURRENT IMPLANTABLE CARDIOVERTER DEFIBRILLATOR SHOCKS AFTER TRAFFIC ACCIDENT BECAUSE OF LEAD MICROFRACTURE
    Okutucu, S.
    Karakulak, U. N.
    Evranos, B.
    Sabanov, C.
    Fatihoglu, S. G.
    Sahiner, L.
    Kaya, E. B.
    Aytemir, K.
    Kabakci, G.
    Tokgozoglu, L.
    Ozkutlu, H.
    Oto, A.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 147 : S115 - S115
  • [38] Multiple inappropriate defibrillator shocks due to insulation failure of a Biotronik Linox defibrillator lead with externalized conductor
    Elfarra H.
    Moosdorf R.
    Rybinski L.
    Grimm W.
    Herzschrittmachertherapie + Elektrophysiologie, 2016, 27 (1) : 70 - 72
  • [39] FAILURE OF DEFIBRILLATOR PADDLE AS MIMIC FOR SUBCUTANEOUS PATCH LEAD DURING NONTHORACOTOMY IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEAD CONFIGURATION ASSESSMENT
    PACHULSKI, RT
    KLEIMAN, RB
    JOSEPHSON, ME
    MARCHLINSKI, FE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (09): : 1253 - 1257
  • [40] Management of the patient with frequent discharges from implantable cardioverter defibrillator devices
    Miller, JM
    Hsia, HH
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (03) : 278 - 285