The Rotating Biplanar Linac-Magnetic Resonance Imaging System

被引:211
作者
Fallone, Biagio Gino [1 ]
机构
[1] Univ Alberta, Cross Canc Inst, Edmonton, AB, Canada
关键词
MR-IMAGES;
D O I
10.1016/j.semradonc.2014.02.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We have successfully built linac-magnetic resonance imaging (MR) systems based on a linac waveguide placed between open MR planes (perpendicular) or through the central opening of one of the planes (parallel) to improve dosimetric properties. It rotates on a gantry to irradiate at any angle. Irradiation during MR imaging and automatic 2-dimensional MR image based target tracking and automatic beam steering to the moving target have been demonstrated with our systems. The functioning whole-body system (0.6-T MR and 6-MV linac) has been installed in an existing clinical vault without removing the walls or the ceiling and without the need of a helium exhaust vent. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:200 / 202
页数:3
相关论文
共 10 条
[1]   Effect of longitudinal magnetic fields on a simulated in-line 6 MV linac [J].
Aubin, J. St. ;
Santos, D. M. ;
Steciw, S. ;
Fallone, B. G. .
MEDICAL PHYSICS, 2010, 37 (09) :4916-4923
[2]   A two-step scheme for distortion rectification of magnetic resonance images [J].
Baldwin, Lesley N. ;
Wachowicz, Keith ;
Fallone, B. Gino .
MEDICAL PHYSICS, 2009, 36 (09) :3917-3926
[3]   Effect of radiation induced current on the quality of MR images in an integrated linac-MR system [J].
Burke, Ben ;
Wachowicz, K. ;
Fallone, B. G. ;
Rathee, Satyapal .
MEDICAL PHYSICS, 2012, 39 (10) :6139-6147
[4]   First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system [J].
Fallone, B. G. ;
Murray, B. ;
Rathee, S. ;
Stanescu, T. ;
Steciw, S. ;
Vidakovic, S. ;
Blosser, E. ;
Tymofichuk, D. .
MEDICAL PHYSICS, 2009, 36 (06) :2084-2088
[5]   Skin dose in longitudinal and transverse linac-MRIs using Monte Carlo and realistic 3D MRI field models [J].
Keyvanloo, A. ;
Burke, B. ;
Warkentin, B. ;
Tadic, T. ;
Rathee, S. ;
Kirkby, C. ;
Santos, D. M. ;
Fallone, B. G. .
MEDICAL PHYSICS, 2012, 39 (10) :6509-6521
[6]   Lung dosimetry in a linac-MRI radiotherapy unit with a longitudinal magnetic field [J].
Kirkby, C. ;
Murray, B. ;
Rathee, S. ;
Fallone, B. G. .
MEDICAL PHYSICS, 2010, 37 (09) :4722-4732
[7]   Radio frequency shielding for a linac-MRI system [J].
Lamey, M. ;
Burke, B. ;
Blosser, E. ;
Rathee, S. ;
De Zanche, N. ;
Fallone, B. G. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (04) :995-1006
[8]   Waveguide detuning caused by transverse magnetic fields on a simulated in-line 6 MV linac [J].
St Aubin, J. ;
Steciw, S. ;
Fallone, B. G. .
MEDICAL PHYSICS, 2010, 37 (09) :4751-4754
[9]   Design and Optimization of Superconducting MRI Magnet Systems With Magnetic Materials [J].
Tadic, Tony ;
Fallone, B. Gino .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2012, 22 (02)
[10]   First demonstration of intrafractional tumor-tracked irradiation using 2D phantom MR images on a prototype linac-MR [J].
Yun, Jihyun ;
Wachowicz, Keith ;
Mackenzie, Marc ;
Rathee, Satyapal ;
Robinson, Don ;
Fallone, B. G. .
MEDICAL PHYSICS, 2013, 40 (05)