Model of a porous regenerator used for magnetic refrigeration at room temperature

被引:42
|
作者
Bouchard, Jonathan [2 ]
Nesreddine, Hakim [1 ]
Galanis, Nicolas [2 ]
机构
[1] Hydroquebec, Lab Technol Energie, Shawinigan, PQ G9N 7N5, Canada
[2] Univ Sherbrooke, Sherbrooke, PQ J1K 2R1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Porous regenerator; Magnetocaloric effect; Magnetic refrigeration; CFD;
D O I
10.1016/j.ijheatmasstransfer.2008.08.031
中图分类号
O414.1 [热力学];
学科分类号
摘要
A transient three-dimensional model of a porous regenerator operating at room temperature is presented. The solid magnetic material and the regeneration fluid are modeled separately. The fluid flows through interstitial channels formed by a regular matrix of solid particles. The velocity, pressure and temperature fields are obtained from the simultaneous Solution of the Navier-Stokes and energy equations with variable properties in the solid and the Boussinesq approximation for the fluid. The magnetocaloric effect (MCE) is taken into account by the inclusion of a source term in the energy equation for the magnetic solid. Special numerical schemes are used to avoid unrealistic computation time and memory requirements. Typical velocity fields and transient temperature profiles are presented. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1223 / 1229
页数:7
相关论文
共 50 条
  • [1] A numerical model of an Active Magnetic Regenerator for refrigeration at room temperature
    Aprea, Ciro
    Maiorino, Angelo
    Mastrullo, Rita
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL TECHNOLOGY AND MANAGEMENT, 2007, 7 (1-2) : 113 - 133
  • [2] EXPERIMENTAL INVESTIGATION ON REFRIGERATION PERFORMANCE OF A RECIPROCATING ACTIVE MAGNETIC REGENERATOR OF ROOM TEMPERATURE MAGNETIC REFRIGERATION
    Yu, B. F.
    Gao, Q.
    Wang, C. F.
    Zhang, B.
    Yang, D. X.
    Zhang, Y.
    1ST INTERNATIONAL CONFERENCE ON MAGNETIC REFRIGERATION AT ROOM TEMPERATURE, 2005, : 375 - 391
  • [3] Experimental investigation on refrigeration performance of a reciprocating active magnetic regenerator of room temperature magnetic refrigeration
    Gao, Q.
    Yu, B. F.
    Wang, C. F.
    Zhang, B.
    Yang, D. X.
    Zhang, Y.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (08): : 1274 - 1285
  • [4] Numerical modeling on a reciprocating active magnetic regenerator refrigeration in room temperature
    Li, Jing
    Numazawa, Takenori
    Nakagome, Hideki
    Matsumoto, Koichi
    CRYOGENICS, 2011, 51 (06) : 347 - 352
  • [5] Numerical investigations on internal temperature distribution and refrigeration performance of reciprocating active magnetic regenerator of room temperature magnetic refrigeration
    Liu, Min
    Yu, Bingfeng
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (03): : 617 - 627
  • [6] NEW METHOD FOR ANALYSIS OF ACTIVE MAGNETIC REGENERATOR IN MAGNETIC REFRIGERATION AT ROOM-TEMPERATURE
    HU, JC
    XIAO, JH
    CRYOGENICS, 1995, 35 (02) : 101 - 104
  • [7] Numerical simulation on porous rotary active magnetic regenerator in room temperature
    Hou, Pu-Xiu
    Liu, Chao-Peng
    Wu, Jiang-Hong
    Binggong Xuebao/Acta Armamentarii, 2015, 36 (05): : 938 - 945
  • [8] Modeling of Graded Active Magnetic Regenerator for Room-Temperature, Energy-Efficient Refrigeration
    Hsieh, Chih-Ming
    Su, Yu-Chuan
    Lee, Chih-Hao
    Cheng, Pai-Hsiang
    Leou, Keh-Chyang
    IEEE TRANSACTIONS ON MAGNETICS, 2014, 50 (01)
  • [9] Numerical simulation of active magnetic regenerative refrigeration using Gyroid structured regenerator at room temperature
    Nishioka, Sotaro
    Sepehri-Amin, Hossein
    Saito, Akiko T.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2025, 170 : 468 - 476
  • [10] A numerical model of an active magnetic regenerator refrigeration system
    Engelbrecht, KL
    Nellis, GF
    Klein, SA
    CRYOCOOLERS 13, 2005, : 471 - 480