Improving tangential resolution with a modified delay-and-sum reconstruction algorithm in photoacoustic and thermoacoustic tomography

被引:72
作者
Pramanik, Manojit [1 ,2 ]
机构
[1] Indian Inst Sci, Biomed Imaging Lab, Bangalore 560012, Karnataka, India
[2] Nanyang Technol Univ, Sch Chem & Biomed Engn, Div Bioengn, Biomed Imaging Lab, Singapore 637457, Singapore
关键词
FREQUENCY-DOMAIN RECONSTRUCTION; IN-VIVO; IMAGE-RECONSTRUCTION; BIOLOGICAL TISSUES; GEOMETRY; DESIGN; SYSTEM; BRAIN;
D O I
10.1364/JOSAA.31.000621
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Spatial resolution in photoacoustic and thermoacoustic tomography is ultrasound transducer (detector) bandwidth limited. For a circular scanning geometry the axial (radial) resolution is not affected by the detector aperture, but the tangential (lateral) resolution is highly dependent on the aperture size, and it is also spatially varying (depending on the location relative to the scanning center). Several approaches have been reported to counter this problem by physically attaching a negative acoustic lens in front of the nonfocused transducer or by using virtual point detectors. Here, we have implemented a modified delay-and-sum reconstruction method, which takes into account the large aperture of the detector, leading to more than fivefold improvement in the tangential resolution in photoacoustic (and thermoacoustic) tomography. Three different types of numerical phantoms were used to validate our reconstruction method. It is also shown that we were able to preserve the shape of the reconstructed objects with the modified algorithm. (C) 2014 Optical Society of America
引用
收藏
页码:621 / 627
页数:7
相关论文
共 34 条
[1]   Half-time image reconstruction in thermoacoustic tomography [J].
Anastasio, MA ;
Zhang, J ;
Pan, XC ;
Zou, Y ;
Ku, G ;
Wang, LHV .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (02) :199-210
[2]   Three-dimensional photoacoustic imaging by sparsearray detection and iterative image reconstruction [J].
Ephrat, Pinhas ;
Keenliside, Lynn ;
Seabrook, Adam ;
Prato, Frank S. ;
Carson, Jeffrey J. L. .
JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (05)
[3]   Laser optoacoustic imaging system for detection of breast cancer [J].
Ermilov, Sergey A. ;
Khamapirad, Tuenchit ;
Conjusteau, Andre ;
Leonard, Morton H. ;
Lacewell, Ron ;
Mehta, Ketan ;
Miller, Tom ;
Oraevsky, Alexander A. .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (02)
[4]   Full-Wave Iterative Image Reconstruction in Photoacoustic Tomography With Acoustically Inhomogeneous Media [J].
Huang, Chao ;
Wang, Kun ;
Nie, Liming ;
Wang, Lihong V. ;
Anastasio, Mark A. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (06) :1097-1110
[5]   Thermoacoustic CT with radio waves: A medical imaging paradigm [J].
Kruger, RA ;
Kopecky, KK ;
Aisen, AM ;
Reinecke, DR ;
Kruger, GA ;
Kiser, WL .
RADIOLOGY, 1999, 211 (01) :275-278
[6]   Thermoacoustic and photoacoustic tomography of thick biological tissues toward breast imaging [J].
Ku, G ;
Fornage, BD ;
Jin, X ;
Xu, MH ;
Hunt, KK ;
Wang, LV .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2005, 4 (05) :559-565
[7]   Imaging of tumor angiogenesis in rat brains in vivo by photoacoustic tomography [J].
Ku, G ;
Wang, XD ;
Xie, XY ;
Stoica, G ;
Wang, LHV .
APPLIED OPTICS, 2005, 44 (05) :770-775
[8]   Scanning microwave-induced thermoacoustic tomography: Signal, resolution, and contrast [J].
Ku, G ;
Wang, LHV .
MEDICAL PHYSICS, 2001, 28 (01) :4-10
[9]   Real-time photoacoustic tomography of cortical hemodynamics in small animals [J].
Li, Changhui ;
Aguirre, Andres ;
Gamelin, John ;
Maurudis, Anastasios ;
Zhu, Quing ;
Wang, Lihong V. .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (01)
[10]   High-numerical-aperture-based virtual point detectors for photoacoustic tomography [J].
Li, Changhui ;
Wang, Lihong V. .
APPLIED PHYSICS LETTERS, 2008, 93 (03)