The use of a Hamamatsu X-ray image intensifier with a cooled CCD as a solution X-ray scattering detector

被引:48
|
作者
Fujisawa, T
Inoko, Y
Yagi, N
机构
[1] RIKEN, Harima Inst, SPring 8, Struct Biophys Lab, Sayo, Hyogo 6795148, Japan
[2] Osaka Univ, Grad Sch Engn Sci, Div Biophys Engn, Toyonaka, Osaka 5608531, Japan
[3] Japan Synchrotron Radiat Res Inst, JASRI, Expt Res Div, SPring 8, Sayo, Hyogo 6795198, Japan
关键词
SPring-8; solution X-ray scattering; X-ray image intensifier with cooled CCD; apoferritin;
D O I
10.1107/S0909049599010250
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
CCD detectors are now widely used in many synchrotron small-angle X-ray scattering beamlines. The use of an X-ray image intensifier with cooled CCD (XR-II + CCD) was studied, especially for use in synchrotron solution X-ray scattering. Two samples, polystyrene latex and apoferritin, were used. These two samples have fine structure in the solution scattering profile due to symmetry and narrow size distribution. The recorded scattering profile, in comparison with that obtained by a position-sensitive proportional counter (PSPC), showed that XR-II + CCD has a much smaller practical dynamic range (100:1) than that of a pixel well (7500:1). This limited dynamic range was overcome by placing various-size masks on the detection plane, thereby eliminating the high-intensity region. The images recorded with various masks were combined, and the reconstituted solution scattering profile was submitted to various analyses, including Guinier analysis, power-law analysis, size distribution analysis and calculation of radial density distributions. The results were the same as those obtained with the PSPC. This indicates that spatial distortion as well as shading, a decrease in sensitivity from the centre to the edge of the detecting region [Amemiya, Ito, Yagi, Asano, Wakabayashi, Ueki & Endo (1995). Rev. Sci. Instrum. 66, 2290-2294], have very little effect on the SBXS results. This paper presents a practical protocol for obtaining a reliable solution scattering profile given the limitations of XR-II + CCD for synchrotron solution X-ray scattering.
引用
收藏
页码:1106 / 1114
页数:9
相关论文
共 50 条
  • [31] X-ray polarimetry using the photoeffect in a CCD detector
    Buschhorn, G.
    Kotthaus, R.
    Kufner, W.
    Roessl, W.
    Rzepka, M.
    Schmidt, K.H.
    Genz, H.
    Graef, H.-D.
    Hoffmann-Stascheck, P.
    Nething, U.
    Richter, A.
    Dix, W.-R.
    Illing, G.
    Lohmann, M.
    Pflueger, J.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A346 (03) : 578 - 588
  • [32] Kodak CCD-Based Detector for Small Angle X-Ray Scattering
    Lee, Hok-ling
    Madden, Timothy
    Fernandez, Patricia
    Lee, Byeongdu
    Seifert, Soenke
    Weizeorick, John
    Molitsky, Michael
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1807 - +
  • [33] AN X-RAY IMAGE INTENSIFIER SYSTEM FOR PRECISION WAVELENGTH DISPERSIVE-X-RAY SPECTROSCOPY
    HAILEY, CJ
    LUPTON, JH
    SIEGMUND, OHW
    STEWART, RE
    ZIOCK, KP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (08): : 2121 - 2126
  • [34] HARD X-RAY-DETECTOR WITH AN MCP IMAGE INTENSIFIER WORKING IN THE 100 KEV 1 MEV X-RAY RANGE
    VEAUX, J
    CAVAILLER, C
    GEX, JP
    HAUDUCOEUR, A
    HYVERNAGE, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (06): : 1562 - 1567
  • [35] Image noise properties of a phosphor-coated CCD X-ray detector
    Gambaccini, M
    Taibi, A
    Baldelli, P
    Del Guerra, A
    Tuffanelli, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3): : 508 - 510
  • [36] Image noise properties of a phosphor-coated CCD X-ray detector
    Gambaccini, M.
    Taibi, A.
    Baldelli, P.
    Del Guerra, A.
    Tuffanelli, A.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 409 (1-3): : 508 - 510
  • [37] X-ray Peltier cooled detectors for X-ray fluorescence analysis
    Loupilov, A
    Sokolov, A
    Gostilo, V
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 463 - 464
  • [38] CHARACTERISTICS OF A CHANNEL PLATE AS AN IMAGE INTENSIFIER FOR X-RAY TOPOGRAPHY
    ANDO, M
    HOSOYA, S
    NAMIKAWA, K
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1976, 9 (AUG1) : 269 - 272
  • [39] EVALUATION OF AN EXPERIMENTAL MICROCHANNEL PLATE X-RAY IMAGE INTENSIFIER
    GOULD, R
    BJARNGARD, B
    JUDY, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 599 - 599
  • [40] IMAGE INTENSIFIER SYSTEM FOR DYNAMIC X-RAY DIFFRACTION STUDIES
    REIFSNIDER, K
    GREEN, RE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1968, 39 (11): : 1651 - +