The use of a Hamamatsu X-ray image intensifier with a cooled CCD as a solution X-ray scattering detector

被引:48
|
作者
Fujisawa, T
Inoko, Y
Yagi, N
机构
[1] RIKEN, Harima Inst, SPring 8, Struct Biophys Lab, Sayo, Hyogo 6795148, Japan
[2] Osaka Univ, Grad Sch Engn Sci, Div Biophys Engn, Toyonaka, Osaka 5608531, Japan
[3] Japan Synchrotron Radiat Res Inst, JASRI, Expt Res Div, SPring 8, Sayo, Hyogo 6795198, Japan
关键词
SPring-8; solution X-ray scattering; X-ray image intensifier with cooled CCD; apoferritin;
D O I
10.1107/S0909049599010250
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
CCD detectors are now widely used in many synchrotron small-angle X-ray scattering beamlines. The use of an X-ray image intensifier with cooled CCD (XR-II + CCD) was studied, especially for use in synchrotron solution X-ray scattering. Two samples, polystyrene latex and apoferritin, were used. These two samples have fine structure in the solution scattering profile due to symmetry and narrow size distribution. The recorded scattering profile, in comparison with that obtained by a position-sensitive proportional counter (PSPC), showed that XR-II + CCD has a much smaller practical dynamic range (100:1) than that of a pixel well (7500:1). This limited dynamic range was overcome by placing various-size masks on the detection plane, thereby eliminating the high-intensity region. The images recorded with various masks were combined, and the reconstituted solution scattering profile was submitted to various analyses, including Guinier analysis, power-law analysis, size distribution analysis and calculation of radial density distributions. The results were the same as those obtained with the PSPC. This indicates that spatial distortion as well as shading, a decrease in sensitivity from the centre to the edge of the detecting region [Amemiya, Ito, Yagi, Asano, Wakabayashi, Ueki & Endo (1995). Rev. Sci. Instrum. 66, 2290-2294], have very little effect on the SBXS results. This paper presents a practical protocol for obtaining a reliable solution scattering profile given the limitations of XR-II + CCD for synchrotron solution X-ray scattering.
引用
收藏
页码:1106 / 1114
页数:9
相关论文
共 50 条
  • [21] Hard X-ray response of the XIS-CCD for ASTRO-E: qualification of the X-ray CCD detector
    Nishiuchi, M.
    Koyama, K.
    Awaki, H.
    Tsuru, T.
    Sakano, M.
    Hamaguchi, K.
    Murakami, H.
    Tsunemi, H.
    Hayashida, K.
    Kitamoto, S.
    Miyata, E.
    Dotani, T.
    Ozaki, M.
    Bautz, M.
    Doty, J.
    Kissel, S.
    Foster, R.
    Ricker, G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999, 436 (1-2): : 79 - 84
  • [22] The hard X-ray response of the XIS-CCD for Astro-E: qualification of the X-ray CCD detector
    Nishiuchi, M
    Koyama, K
    Awaki, H
    Tsuru, T
    Sakano, M
    Hamaguchi, K
    Murakami, H
    Tsunemi, H
    Hayashida, K
    Kitamoto, S
    Miyata, E
    Dotani, T
    Ozaki, M
    Bautz, M
    Doty, J
    Kissel, S
    Foster, R
    Ricker, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 79 - 84
  • [23] Image x-ray emission converters and microstrip porous dielectric x-ray detector
    Lorikyan, M.P.
    Journal of Applied Physics, 2008, 104 (09):
  • [24] Image x-ray emission converters and microstrip porous dielectric x-ray detector
    Lorikyan, M. P.
    JOURNAL OF APPLIED PHYSICS, 2008, 104 (09)
  • [25] X-ray Solution Scattering Studies at the Life Sciences X-ray Scattering (LiX) Beamline
    Byrnes, James
    Chodankar, Shirish
    Lazo, Edwin
    Qian, Kun
    Antonelli, Stephen
    Yang, Lin
    FASEB JOURNAL, 2021, 35
  • [26] A multiple CCD X-ray detector and its first operation with synchrotron radiation X-ray beam
    Suzuki, M
    Yamamoto, M
    Kumasaka, T
    Sato, K
    Toyokawa, H
    Aries, IF
    Jerram, PA
    Ueki, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2): : 174 - 181
  • [27] X-RAY POLARIMETRY USING THE PHOTOEFFECT IN A CCD DETECTOR
    BUSCHHORN, G
    KOTTHAUS, R
    KUFNER, W
    ROSSL, W
    RZEPKA, M
    SCHMIDT, KH
    GENZ, H
    GRAF, HD
    HOFFMANNSTASCHECK, P
    NETHING, U
    RICHTER, A
    DIX, WR
    ILLING, G
    LOHMANN, M
    PFLUGER, J
    REIME, B
    SCHILDWACHTER, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (03): : 578 - 588
  • [28] Scanning CCD Detector for X-ray Powder Diffraction
    Madden, T.
    Baldwin, J.
    Von Dreele, R.
    Suchomel, M.
    Toby, B. H.
    17TH PAN-AMERICAN SYNCHROTRON RADIATION INSTRUMENTATION CONFERENCE SRI2013, 2014, 493
  • [29] Spatial resolution of a hard x-ray CCD detector
    Seely, John F.
    Pereira, Nino R.
    Weber, Bruce V.
    Schumer, Joseph W.
    Apruzese, John P.
    Hudson, Lawrence T.
    Szabo, Csilla I.
    Boyer, Craig N.
    Skirlo, Scott
    APPLIED OPTICS, 2010, 49 (23) : 4372 - 4378
  • [30] Multiple CCD detector for macromolecular x-ray crystallography
    Phillips, WC
    Stanton, M
    Stewart, A
    Qian, H
    Ingersoll, C
    Sweet, RM
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2000, 33 : 243 - 251