The use of a Hamamatsu X-ray image intensifier with a cooled CCD as a solution X-ray scattering detector

被引:48
|
作者
Fujisawa, T
Inoko, Y
Yagi, N
机构
[1] RIKEN, Harima Inst, SPring 8, Struct Biophys Lab, Sayo, Hyogo 6795148, Japan
[2] Osaka Univ, Grad Sch Engn Sci, Div Biophys Engn, Toyonaka, Osaka 5608531, Japan
[3] Japan Synchrotron Radiat Res Inst, JASRI, Expt Res Div, SPring 8, Sayo, Hyogo 6795198, Japan
关键词
SPring-8; solution X-ray scattering; X-ray image intensifier with cooled CCD; apoferritin;
D O I
10.1107/S0909049599010250
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
CCD detectors are now widely used in many synchrotron small-angle X-ray scattering beamlines. The use of an X-ray image intensifier with cooled CCD (XR-II + CCD) was studied, especially for use in synchrotron solution X-ray scattering. Two samples, polystyrene latex and apoferritin, were used. These two samples have fine structure in the solution scattering profile due to symmetry and narrow size distribution. The recorded scattering profile, in comparison with that obtained by a position-sensitive proportional counter (PSPC), showed that XR-II + CCD has a much smaller practical dynamic range (100:1) than that of a pixel well (7500:1). This limited dynamic range was overcome by placing various-size masks on the detection plane, thereby eliminating the high-intensity region. The images recorded with various masks were combined, and the reconstituted solution scattering profile was submitted to various analyses, including Guinier analysis, power-law analysis, size distribution analysis and calculation of radial density distributions. The results were the same as those obtained with the PSPC. This indicates that spatial distortion as well as shading, a decrease in sensitivity from the centre to the edge of the detecting region [Amemiya, Ito, Yagi, Asano, Wakabayashi, Ueki & Endo (1995). Rev. Sci. Instrum. 66, 2290-2294], have very little effect on the SBXS results. This paper presents a practical protocol for obtaining a reliable solution scattering profile given the limitations of XR-II + CCD for synchrotron solution X-ray scattering.
引用
收藏
页码:1106 / 1114
页数:9
相关论文
共 50 条
  • [1] INTRAORAL X-RAY FLUOROSCOPY WITH IMAGE INTENSIFIER AND CCD
    BOUCHIER, G
    LEDENMAT, D
    CAMUS, JP
    ROVILLE, JC
    MARTIN, G
    RICHARD, JC
    JOURNAL OF DENTAL RESEARCH, 1986, 65 (04) : 558 - 558
  • [2] X-ray image intensifier
    Balter, S
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 1999, 46 (02) : 238 - 244
  • [3] X-RAY IMAGE INTENSIFIER
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1954, 2 (4895): : 1044 - 1044
  • [4] PERFORMANCE OF A MEDICAL X-RAY IMAGE INTENSIFIER OPTICALLY COUPLED TO A COOLED CCD CAMERA
    MOY, JP
    MORSE, J
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1992, (121): : 265 - 271
  • [5] X-RAY IMAGE INTENSIFIER
    MCDONALD, RE
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (05): : 691 - 691
  • [6] MEASUREMENT OF X-RAY IMAGE INTENSIFIER SHARPNESS IN THE X-RAY DEPARTMENT
    LEHERON, JC
    POLETTI, JL
    PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01): : 93 - 104
  • [7] The solid-state x-ray image intensifier (SSXII): An EMCCD-Based x-ray detector
    Kuhls-Gilcrist, Andrew
    Yadava, Girijesh
    Patel, Vikas
    Jain, Amit
    Bednarek, Daniel R.
    Rudin, Stephen
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [8] USE OF A MEDICAL X-RAY IMAGE INTENSIFIER IN LAUE INVESTIGATIONS
    FUCHS, EG
    VARGA, L
    ACTA TECHNICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1971, 70 (1-2): : 191 - &
  • [9] Novel combined X-ray image intensifier
    Yu, Chun-Yu
    Chang, Ben-Kang
    Fu, Rong-Guo
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2007, 27 (03): : 610 - 613
  • [10] The novel combined X-ray image intensifier
    Yu Chun-yu
    Chang Ben-kang
    Fu Rong-guo
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27 (03) : 610 - 613