Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments

被引:80
作者
Berutti, E.
Angelini, E.
Rigolone, M.
Migliaretti, G.
Pasqualini, D.
机构
[1] Politecn Torino, Sch Dent, Dept Endodont, Turin, Italy
[2] Politecn Torino, Dept Mat Sci & Chem Engn, Turin, Italy
[3] Politecn Torino, Dept Microbiol & Publ Hlth, Turin, Italy
关键词
cyclic fatigue; fracture; nickel-titanium; rotary instruments; sodium hypochlorite;
D O I
10.1111/j.1365-2591.2006.01134.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To evaluate the influence of immersion in NaOCl on resistance to cyclic fatigue fracture and corrosion of ProTaper NiTi Rotary instruments. Methodology A total of 120 new ProTaper NiTi Rotary files (F2) were randomized and assigned to three different groups of 40 each. Group 1 was the control group; 20 mm (excluding the shaft) of group 2 instruments were immersed in 5% NaOCl at 50 degrees C for 5 min; instruments in group 3 were completely immersed in 5% NaOCl at 50 degrees C for 5 min. All instruments were then tested for cyclic fatigue, recording the time in seconds to fracture. Data were analysed by the Kruskall-Wallis test and post-hoc multiple comparisons (P < 0.05). Micromorphological and microchemical analyses were also completed by means of a field emission scanning electron microscopy (SEM) on those instruments in group 3 that had undergone early fracture. Results Instruments in group 3 had a significantly lower resistance to fracture because of cyclic fatigue than those in groups 1 and 2 (P < 0.001). In some instruments in group 3, early fracture occurred after only a few seconds of fatigue testing. SEM observations revealed evident signs of corrosion of the fractured instruments. Conclusion Group 3 had significantly reduced resistance to cyclic fatigue compared with instruments in groups 1 and 2. The phenomenon of early fracture may be attributed to galvanic corrosion induced by the presence of dissimilar metals, where one acts as the cathode of a galvanic couple, established when the instrument is immersed in NaOCl solution. The NiTi alloy may acts as the anode and thus undergoes corrosion.
引用
收藏
页码:693 / 699
页数:7
相关论文
共 42 条
[1]   CORROSION-RESISTANCE OF SOLDER JOINTS FOR REMOVABLE PARTIAL DENTURES [J].
ANGELINI, E ;
BONINO, P ;
PEZZOLI, M .
DENTAL MATERIALS, 1988, 4 (05) :255-260
[2]  
Angelini E, 2002, INTEGRATED BIOMATERIALS SCIENCE, P297, DOI 10.1007/0-306-47583-9_7
[3]   A scanning electron microscopic evaluation of the debridement capability of sodium hypochlorite at different temperatures [J].
Berutti, E ;
Marini, R .
JOURNAL OF ENDODONTICS, 1996, 22 (09) :467-470
[4]   Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile [J].
Berutti, E ;
Chiandussi, G ;
Gaviglio, I ;
Ibba, A .
JOURNAL OF ENDODONTICS, 2003, 29 (01) :15-19
[5]   FEASIBILITY OF A COMBINED CARRIER TEST FOR DISINFECTANTS - STUDIES WITH A MIXTURE OF 5 TYPES OF MICROORGANISMS [J].
BEST, M ;
SPRINGTHORPE, VS ;
SATTAR, SA .
AMERICAN JOURNAL OF INFECTION CONTROL, 1994, 22 (03) :152-162
[6]  
Busslinger A, 1998, INT ENDOD J, V31, P290
[7]   THE ANTIBACTERIAL ACTION OF SODIUM-HYPOCHLORITE AND EDTA IN 60 CASES OF ENDODONTIC THERAPY [J].
BYSTROM, A ;
SUNDQVIST, G .
INTERNATIONAL ENDODONTIC JOURNAL, 1985, 18 (01) :35-40
[8]   BACTERIOLOGIC EVALUATION OF THE EFFECT OF 0.5 PERCENT SODIUM-HYPOCHLORITE IN ENDODONTIC THERAPY [J].
BYSTROM, A ;
SUNDQVIST, G .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1983, 55 (03) :307-312
[9]   EFFECT OF TEMPERATURE ON COLLAGEN-DISSOLVING ABILITY OF SODIUM-HYPOCHLORITE ENDODONTIC IRRIGANT [J].
CUNNINGHAM, WT ;
BALEKJIAN, AY .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1980, 49 (02) :175-177
[10]  
Dychdala G.R., 1991, DISINFECTION STERILI, P131