Posterior Capsule Opacification With Two Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial

被引:22
作者
Leydolt, Christina [1 ]
Schartmuller, Daniel [1 ]
Schwarzenbacher, Luca [1 ]
Roggla, Veronika [1 ]
Schriefl, Sabine [1 ]
Menapace, Rupert [1 ]
机构
[1] Med Univ Vienna, Dept Ophthalmol, Waehringer Guertel 18-20, A-1090 Vienna, Austria
关键词
OPTIC EDGE DESIGN; CONDUCTIVE KERATOPLASTY; MODERATE HYPEROPIA; EPITHELIAL-CELLS; SILICONE; GLISTENINGS; POLYMETHYLMETHACRYLATE; ACRYSOF; BEND;
D O I
10.1016/j.ajo.2020.04.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the incidence and intensity of posterior capsule opacification (PCO) and neodymium- yttrium-aluminum-garnet (Nd:YAG) capsulotomy rates between 2 similar open-loop single-piece hydrophobic acrylic intraocular lenses (IOLs) that differ in the proprietary material characteristics and design features, over a period of 3 years. DESIGN: Randomized, prospective, patient- and examiner-masked clinical trial with intraindividual comparison. METHODS: SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. PATIENT POPULATION: Eighty patients (160 eyes) had bilateral cataract surgery and received a Vivinex XY1 IOL in 1 eye and an AcrySof SN60WFIOL in the other eye. OBSERVATION PROCEDURES: Follow-up examinations were performed 3 years after surgery. Digital retroillumination images were taken of each eye. The amount of PCO (score: 0-10) was assessed subjectively at the slit lamp and objectively using automated image analysis software (AQUA). MAIN OUTCOME MEASURE: PCO score (scale, 0-10). RESULTS: The mean objective PCO score of the Vivinex XY1 IOLs was 0.9 +/- 0.8 compared to the PCO score of 1.4 +/- 1.1 for the AcrySof SN60WF IOLs (P < .001). Three years postoperatively, 11.4% of patients had an Nd:YAG capsulotomy in the Vivinex XY1 eye and 18.6% had a capsulotomy in the AcrySof SN60WF eye (P = .23). CONCLUSION: The new hydrophobic acrylic Vivinex XY1 IOL showed significantly lower PCO rates and lower YAG rates compared to the AcrySof SN60WF IOL. The interaction of various factors such as hydrophobic material, smooth optic surface, and sharp posterior optic edge plays a key role in PCO development. (C) 2020 The Authors. Published by Elsevier Inc.
引用
收藏
页码:224 / 231
页数:8
相关论文
共 50 条
  • [31] INCIDENCE OF POSTERIOR CAPSULE OPACIFICATION IN EYES WITH EXFOLIATION SYNDROME AND HEPARIN-SURFACE-MODIFIED INTRAOCULAR LENSES
    ZETTERSTROM, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (03) : 344 - 347
  • [32] Epidemiological evaluation of YAG capsulotomy incidence for posterior capsule opacification in various intraocular lenses in Japanese eyes
    Nishi, Yutaro
    Ikeda, Tomohiro
    Nishi, Kayo
    Mimura, Osamu
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 1613 - 1617
  • [33] Fellow-eye comparison of posterior capsule opacification between 2 aspheric microincision intraocular lenses
    Nanavaty, Mayank A.
    Spalton, David J.
    Gala, Kavita B.
    Dhital, Anish
    Boyce, James
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (05) : 705 - 711
  • [34] Intraindividual comparison of capsule behavior of 2 hydrophobic acrylic intraocular lenses during a 5-year follow-up
    Kahraman, Guenal
    Ferdinaro, Clara
    Wetzel, Barbara
    Bernhart, Clemens
    Prager, Franz
    Amon, Michael
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (02) : 228 - 233
  • [35] Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery: An updated meta-analysis
    Zhao, Yang
    Yang, Ke
    Li, Jiaxin
    Huang, Yang
    Zhu, Siquan
    MEDICINE, 2017, 96 (44)
  • [36] Glistenings, anterior/posterior capsular opacification and incidence of Nd:YAG laser treatments with two aspheric hydrophobic acrylic intraocular lenses - a long-term intra-individual study
    Johansson, Bjorn
    ACTA OPHTHALMOLOGICA, 2017, 95 (07) : 671 - 677
  • [37] Selenium functionalized intraocular lenses inhibit posterior capsule opacification in an ex vivo canine lens capsular bag assay
    Pot, Simon A.
    Chandler, Heather L.
    Colitz, Carmen M. H.
    Bentley, Ellison
    Dubielzig, Richard R.
    Mosley, Thomas S.
    Reid, Ted W.
    Murphy, Christopher J.
    EXPERIMENTAL EYE RESEARCH, 2009, 89 (05) : 728 - 734
  • [38] Comparison of posterior capsule opacification between a 1-piece and a 3-piece microincision intraocular lens
    Prinz, Ana
    Vecsei-Marlovits, Pia Veronika
    Sonderhof, Dietrich
    Irsigler, Paul
    Findl, Oliver
    Weingessel, Birgit
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (01) : 18 - 22
  • [39] Long-term results of trypan blue dye irrigation in the capsular bag to prevent posterior capsule opacification: A randomized trial
    Joshi, Rajesh Subhash
    Hussain, Murtaza Saifuddin
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (12) : 1440 - 1444
  • [40] Supercritical fluid technology for the development of innovative ophthalmic medical devices: Drug loaded intraocular lenses to mitigate posterior capsule opacification
    Ongkasin, Kanjana
    Masmoudi, Yasmine
    Wertheimer, Christian M.
    Hillenmayer, Anna
    Eibl-Lindner, Kirsten H.
    Badens, Elisabeth
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2020, 149 : 248 - 256