Posterior Capsule Opacification With Two Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial

被引:22
作者
Leydolt, Christina [1 ]
Schartmuller, Daniel [1 ]
Schwarzenbacher, Luca [1 ]
Roggla, Veronika [1 ]
Schriefl, Sabine [1 ]
Menapace, Rupert [1 ]
机构
[1] Med Univ Vienna, Dept Ophthalmol, Waehringer Guertel 18-20, A-1090 Vienna, Austria
关键词
OPTIC EDGE DESIGN; CONDUCTIVE KERATOPLASTY; MODERATE HYPEROPIA; EPITHELIAL-CELLS; SILICONE; GLISTENINGS; POLYMETHYLMETHACRYLATE; ACRYSOF; BEND;
D O I
10.1016/j.ajo.2020.04.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the incidence and intensity of posterior capsule opacification (PCO) and neodymium- yttrium-aluminum-garnet (Nd:YAG) capsulotomy rates between 2 similar open-loop single-piece hydrophobic acrylic intraocular lenses (IOLs) that differ in the proprietary material characteristics and design features, over a period of 3 years. DESIGN: Randomized, prospective, patient- and examiner-masked clinical trial with intraindividual comparison. METHODS: SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. PATIENT POPULATION: Eighty patients (160 eyes) had bilateral cataract surgery and received a Vivinex XY1 IOL in 1 eye and an AcrySof SN60WFIOL in the other eye. OBSERVATION PROCEDURES: Follow-up examinations were performed 3 years after surgery. Digital retroillumination images were taken of each eye. The amount of PCO (score: 0-10) was assessed subjectively at the slit lamp and objectively using automated image analysis software (AQUA). MAIN OUTCOME MEASURE: PCO score (scale, 0-10). RESULTS: The mean objective PCO score of the Vivinex XY1 IOLs was 0.9 +/- 0.8 compared to the PCO score of 1.4 +/- 1.1 for the AcrySof SN60WF IOLs (P < .001). Three years postoperatively, 11.4% of patients had an Nd:YAG capsulotomy in the Vivinex XY1 eye and 18.6% had a capsulotomy in the AcrySof SN60WF eye (P = .23). CONCLUSION: The new hydrophobic acrylic Vivinex XY1 IOL showed significantly lower PCO rates and lower YAG rates compared to the AcrySof SN60WF IOL. The interaction of various factors such as hydrophobic material, smooth optic surface, and sharp posterior optic edge plays a key role in PCO development. (C) 2020 The Authors. Published by Elsevier Inc.
引用
收藏
页码:224 / 231
页数:8
相关论文
共 50 条
  • [1] Posterior capsule opacification and neodymium:YAG rates with 2 single-piece hydrophobic acrylic intraocular lenses: Three-year results
    Leydolt, Christina
    Kriechbaum, Katharina
    Schriefl, Sabine
    Pachala, Mojtaba
    Menapace, Rupert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (12) : 1886 - 1892
  • [2] Comparison of posterior capsule opacification with hydrophobic acrylic and hydrophilic acrylic intraocular lenses
    Vasavada, Abhay R.
    Raj, Shetal M.
    Shah, Alpesh
    Shah, Gauri
    Vasavada, Viraj
    Vasavada, Vaishali
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06) : 1050 - 1059
  • [3] Posterior Capsule Opacification with the iMics1 NY-60 and AcrySof SN60WF 1-Piece Hydrophobic Acrylic Intraocular Lenses: 3-Year Results of a Randomized Trial
    Leydolt, Christina
    Schriefl, Sabine
    Stifter, Eva
    Haszcz, Alexandra
    Menapace, Rupert
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (02) : 375 - 381
  • [4] The Effect of Single-Piece Hydrophobic Acrylic Intraocular Lenses on the Development of Posterior Capsule Opacification
    Praveen, Mamidipudi R.
    Shah, Gauri D.
    Vasavada, Abhay R.
    Dave, Khyati H.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (03) : 470 - 478
  • [5] Posterior capsule opacification with 3 intraocular lenses: 12-year prospective study
    Ronbeck, Margrethe
    Kugelberg, Maria
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (01) : 70 - 76
  • [6] Effect of Hydrophobic Acrylic versus Hydrophilic Acrylic Intraocular Lens on Posterior Capsule Opacification: Meta-Analysis
    Li, Ying
    Wang, Jiaxing
    Chen, Zhuo
    Tang, Xin
    PLOS ONE, 2013, 8 (11):
  • [7] Comparison of posterior capsular opacification in heparin-surface-modified hydrophilic acrylic and hydrophobic acrylic intraocular lenses
    Kang, Seungbum
    Choi, Jin A.
    Joo, Choun-Ki
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (03) : 204 - 208
  • [8] Hydrophobic versus hydrophilic acrylic intraocular lens on posterior capsule opacification: a Meta-analysis
    Wu, Qiong
    Li, Yan
    Wu, Lian
    Wang, Cong-Yi
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2022, 15 (06) : 997 - 1004
  • [9] Comparison of posterior capsule opacification and glistenings with 2 hydrophobic acrylic intraocular lenses: 5-to 7-year follow-up
    Chang, Anthony
    Behndig, Anders
    Ronbeck, Margrethe
    Kugelberg, Maria
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (05) : 694 - 698
  • [10] Effect of four different intraocular lenses on posterior capsule opacification
    Duman, Rahmi
    Karel, Fatih
    Ozyol, Pelin
    Ates, Can