Active pixel imagers incorporating pixel-level amplifiers based on polycrystalline-silicon thin-film transistors

被引:34
作者
El-Mohri, Youcef [1 ]
Antonuk, Larry E. [1 ]
Koniczek, Martin [1 ]
Zhao, Qihua [1 ]
Li, Yixin [1 ]
Street, Robert A. [2 ]
Lu, Jeng-Ping [2 ]
机构
[1] Univ Michigan, Med Ctr, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
[2] Xerox Corp, Palo Alto Res Ctr, Palo Alto, CA 94304 USA
基金
美国国家卫生研究院;
关键词
diagnostic radiography; elemental semiconductors; image sensors; photodiodes; silicon; thin film transistors; FLAT-PANEL IMAGERS; DETECTIVE QUANTUM EFFICIENCY; AMORPHOUS-SILICON; HIGH-RESOLUTION; DIGITAL MAMMOGRAPHY; SIGNAL PERFORMANCE; IMAGING PROPERTIES; RADIATION-DAMAGE; MATRIX; NOISE;
D O I
10.1118/1.3116364
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Active matrix, flat-panel imagers (AMFPIs) employing a 2D matrix of a-Si addressing TFTs have become ubiquitous in many x-ray imaging applications due to their numerous advantages. However, under conditions of low exposures and/or high spatial resolution, their signal-to-noise performance is constrained by the modest system gain relative to the electronic additive noise. In this article, a strategy for overcoming this limitation through the incorporation of in-pixel amplification circuits, referred to as active pixel (AP) architectures, using polycrystalline-silicon (poly-Si) TFTs is reported. Compared to a-Si, poly-Si offers substantially higher mobilities, enabling higher TFT currents and the possibility of sophisticated AP designs based on both n- and p-channel TFTs. Three prototype indirect detection arrays employing poly-Si TFTs and a continuous a-Si photodiode structure were characterized. The prototypes consist of an array (PSI-1) that employs a pixel architecture with a single TFT, as well as two arrays (PSI-2 and PSI-3) that employ AP architectures based on three and five TFTs, respectively. While PSI-1 serves as a reference with a design similar to that of conventional AMFPI arrays, PSI-2 and PSI-3 incorporate additional in-pixel amplification circuitry. Compared to PSI-1, results of x-ray sensitivity demonstrate signal gains of similar to 10.7 and 20.9 for PSI-2 and PSI-3, respectively. These values are in reasonable agreement with design expectations, demonstrating that poly-Si AP circuits can be tailored to provide a desired level of signal gain. PSI-2 exhibits the same high levels of charge trapping as those observed for PSI-1 and other conventional arrays employing a continuous photodiode structure. For PSI-3, charge trapping was found to be significantly lower and largely independent of the bias voltage applied across the photodiode. MTF results indicate that the use of a continuous photodiode structure in PSI-1, PSI-2, and PSI-3 results in optical fill factors that are close to unity. In addition, the greater complexity of PSI-2 and PSI-3 pixel circuits, compared to that of PSI-1, has no observable effect on spatial resolution. Both PSI-2 and PSI-3 exhibit high levels of additive noise, resulting in no net improvement in the signal-to-noise performance of these early prototypes compared to conventional AMFPIs. However, faster readout rates, coupled with implementation of multiple sampling protocols allowed by the nondestructive nature of pixel readout, resulted in a significantly lower noise level of similar to 560 e (rms) for PSI-3.
引用
收藏
页码:3340 / 3355
页数:16
相关论文
共 42 条
  • [1] Antonuk LE, 2008, MATER RES SOC SYMP P, V1066, P457
  • [2] An investigation of signal performance enhancements achieved through innovative pixel design across several generations of indirect detection, active matrix, flat-panel arrays
    Antonuk, Larry E.
    Zhao, Qihua
    El-Mohri, Youcef
    Du, Hong
    Wang, Yi
    Street, Robert A.
    Ho, Jackson
    Weisfield, Richard
    Yao, William
    [J]. MEDICAL PHYSICS, 2009, 36 (07) : 3322 - 3339
  • [3] Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications
    Antonuk, LE
    Jee, KW
    El-Mohri, Y
    Maolinbay, M
    Nassif, S
    Rong, X
    Zhao, Q
    Siewerdsen, JH
    Street, RA
    Shah, KS
    [J]. MEDICAL PHYSICS, 2000, 27 (02) : 289 - 306
  • [4] Investigation of strategies to achieve optimal DQE performance from indirect detection, active matrix flat-panel imagers (AMFPIs) through novel pixel amplification architectures
    Antonuk, LE
    Li, YX
    Du, H
    El-Mohri, Y
    Zhao, QH
    Yamamoto, J
    Sawant, A
    Wang, Y
    Su, Z
    Lu, JP
    Street, RA
    Weisfield, R
    Yao, B
    [J]. MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 18 - 31
  • [5] Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation
    Antonuk, LE
    ElMohri, Y
    Siewerdsen, JH
    Yorkston, J
    Huang, W
    Scarpine, VE
    Street, RA
    [J]. MEDICAL PHYSICS, 1997, 24 (01) : 51 - 70
  • [6] ANTONUK LE, 2008, P SPIE, V6913
  • [7] Empirical electro-optical and x-ray performance evaluation of CMOS active pixels sensor for low dose, high resolution x-ray medical imaging
    Arvanitis, C. D.
    Bohndiek, S. E.
    Royle, G.
    Blue, A.
    Liang, H. X.
    Clark, A.
    Prydderch, M.
    Turchetta, R.
    Speller, R.
    [J]. MEDICAL PHYSICS, 2007, 34 (12) : 4612 - 4625
  • [8] RADIATION-DAMAGE OF AMORPHOUS-SILICON PHOTODIODE SENSORS
    BOUDRY, JM
    ANTONUK, LE
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 703 - 707
  • [9] Radiation damage of amorphous silicon, thin-film, field-effect transistors
    Boudry, JM
    Antonuk, LE
    [J]. MEDICAL PHYSICS, 1996, 23 (05) : 743 - 754
  • [10] Pulsed laser crystallization of amorphous silicon for polysilicon flat panel imagers
    Boyce, JB
    Lu, JP
    Ho, J
    Street, RA
    van Schuylenbergh, K
    Wang, Y
    [J]. JOURNAL OF NON-CRYSTALLINE SOLIDS, 2002, 299 : 731 - 735