Quantitative analysis of patulin in apple juice by thin-layer chromatography using a charge coupled device detector

被引:46
作者
Welke, Juliane Elisa [1 ]
Hoeltz, Michele [1 ]
Dottori, Horacio Alberto [2 ]
Noll, Isa Beatriz [1 ]
机构
[1] Univ Fed Rio Grande do Sul, Inst Food Sci & Technol, BR-91570901 Porto Alegre, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Inst Phys, BR-91570901 Porto Alegre, RS, Brazil
来源
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT | 2009年 / 26卷 / 05期
关键词
apple juice; charge-coupled device imaging; patulin; thin-layer chromatography; DIPHASIC DIALYSIS EXTRACTION; PRODUCTS;
D O I
10.1080/02652030802662746
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A method was developed and validated in-house for the detection and quantification of patulin in apple juice concentrate using a charge coupled device (CCD) on thin-layer chromatography (TLC) plates. Samples were extracted with ethyl acetate and then cleaned-up by extraction with a sodium carbonate solution. The method showed a mean recovery of 95%. The quantification and detection limit were 14 g l-1 and 0.005 g per spot, respectively. The CCD camera is sufficiently sensitive to detect changes in spot fluorescence intensity caused by small differences in mycotoxin concentration under homogeneous illumination from a UV light source. The results of validation confirmed the efficiency of the method, which is sensitive enough to be used to quantify patulin in apple juice by producers or for government monitoring/survey programs. The method was applied to the analysis of 16 apple juice concentrate samples and patulin levels ranged from 15 to 46 g l-1. This study demonstrated the applicability of the TLC-CCD technique as a tool for monitoring patulin in apple juice.
引用
收藏
页码:754 / 758
页数:5
相关论文
共 18 条
  • [1] Arranz I, 2005, J AOAC INT, V88, P518
  • [2] Commission of the European communities, 2006, OFF J EUR UNION L, VL364, P1
  • [3] *FAO, 1996, LJ FAO
  • [4] An assay of ganglioside using fluorescence image analysis on a thin-layer chromatography plate
    Hayakawa, T
    Hirai, M
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (23) : 6728 - 6731
  • [5] HOPKINS J, 1993, FOOD CHEM TOXICOL, V31, P455
  • [6] Development of liquid chromatography-electrospray mass spectrometry for the determination of patulin in apple juice: Investigation of its contamination levels in Japan
    Ito, R
    Yamazaki, H
    Inoue, K
    Yoshimura, Y
    Kawaguchi, M
    Nakazawa, H
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (25) : 7464 - 7468
  • [7] Effect of commercial processing stages of apple juice on patulin, fumaric acid and hydroxymethylfurfural (HMF) levels
    Kadakal, Ç
    Sebahattin, N
    Poyrazoglu, ES
    [J]. JOURNAL OF FOOD QUALITY, 2002, 25 (04) : 359 - 368
  • [8] Katerere DR, 2007, J AOAC INT, V90, P162
  • [9] Real-time image acquisition for absorbance detection and quantification in thin-layer chromatography
    Lancaster, M
    Goodall, DM
    Bergström, ET
    McCrossen, S
    Myers, P
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (03) : 905 - 911
  • [10] MacDonald S, 2000, J AOAC INT, V83, P1387