Voltage sag mitigation using a high-frequency-link cycloconverter-based DVR

被引:0
|
作者
Sree, H [1 ]
Mohan, N [1 ]
机构
[1] Guidant Corp, Cardiac Rhythm Management Grp, St Paul, MN 55112 USA
来源
IECON 2000: 26TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4: 21ST CENTURY TECHNOLOGIES AND INDUSTRIAL OPPORTUNITIES | 2000年
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Voltage sags, primarily caused by frequent transmission and distribution-level power system faults, have been known to affect many industrial and commercial customers resulting in yearly losses amounting to millions of dollars. In order to mitigate voltage sags, many solutions at the load-end have been proposed which include Constant Voltage Transformers (CVT's), Uninterruptible Power Supplies (UPS's) and line-frequency-transformer-based series voltage injection devices. These approaches have their respective limitations with regard to capabilities, size arid cost. This paper investigates a new approach to mitigating voltage sags using a high frequency-transformer-link in the series voltage injection approach, to result in savings in size and weight. The paper discusses 3-phase implementation of this approach. It presents simulation results for linear and non-linear loads and experimental results from a single-phase proof-of-concept prototype.
引用
收藏
页码:344 / 349
页数:6
相关论文
共 50 条
  • [1] High-frequency-link cycloconverter-based DVR for voltage sag mitigation
    Sree, H
    Mohan, N
    CONFERENCE RECORD OF THE 2000 TWENTY-FOURTH INTERNATIONAL POWER MODULATOR SYMPOSIUM, 50TH ANNIVERSARY, 2000, : 97 - 100
  • [2] Analysis the operation of DVR in voltage sag mitigation using EMTP
    Monsef, H
    Tamimi, B
    Proceedings of the 4th WSEAS International Conference on Applications of Electrical Engineering, 2005, : 132 - 138
  • [3] Voltage Sag Mitigation Using Direct Converter Based DVR without Error Signal
    Rahman, S. Abdul
    Mitiku, Estifanos Dagnew
    Mule, Shumye Birhan
    Aduye, Gebrie Teshome
    Huluka, Mekete Asmare
    Mesfin, Solomon
    PRZEGLAD ELEKTROTECHNICZNY, 2021, 97 (12): : 34 - 37
  • [4] Mitigation of Voltage Sag/Swell and Harmonics using Self-Supported DVR
    Kumar, Amit
    Pal, Nidhi Singh
    Ansari, M. A.
    PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,
  • [5] Mitigation Voltage Sag/Swell and Harmonics Using DVR Supplied by BES and PV System
    Kiswantono, Agus
    Prasetyo, Eko
    Amirullah
    2018 ELECTRICAL POWER, ELECTRONICS, COMMUNICATIONS, CONTROLS, AND INFORMATICS SEMINAR (EECCIS), 2018, : 36 - 41
  • [6] Improvement of Dynamic Voltage Restorer (DVR) Using Proportional Integral (PI) Controller for Mitigation of Voltage Sag
    Hamza, A. H. A.
    El-Koliel, M. S.
    Ali, M. N.
    El-Eissawi, H.
    Hafez, M. M.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (01): : 44 - 52
  • [7] The Voltage Sag Mitigation Method Based on Hybrid SMES-BES Dynamic Voltage Restorer(DVR)
    Ding, Kai
    Li, Wei
    Hu, Pan
    Hu, Anping
    Tao, Yibin
    Zhuang, Jun
    Lu, Hong
    PROCEEDINGS OF 2019 IEEE 3RD INTERNATIONAL ELECTRICAL AND ENERGY CONFERENCE (CIEEC), 2019, : 545 - 549
  • [8] A Simplified Algorithm for Sag and Harmonic Mitigation using DVR
    Tasre, Mohan B.
    Dhole, Gajanan M.
    Jadhao, Saurabh S.
    Sharma, Rajesh B.
    2017 INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATION, CONTROL AND AUTOMATION (ICCUBEA), 2017,
  • [9] Simulation and Comparison of DVR and D-STATCOM for Voltage Sag Mitigation
    Singh, Shweta
    Rai, Vivekanand
    Kumar, Awadhesh
    Sahay, Kishan Bhusan
    2016 IEEE 6TH INTERNATIONAL CONFERENCE ON POWER SYSTEMS (ICPS), 2016,
  • [10] A High-Frequency-Link Photovoltaic Inverter
    Sivasubramanian, Priyadharshini T.
    Mazumder, Sudip K.
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 3461 - 3470